On 16/06/2015 11:41, [email protected] wrote:
Hello,

I have tested the latest build available from git. Unfortunately I wasn't able 
to check the version number. which debug logs are you referring to ?

Anyway with the latest build, my LiDe 120 is not supported at all (even with 
resolution under 600 dpi).

It may well be that I made a mistake at compile or forgot to update a 
configuration file. Anyone else had a chance to try it ?

Thanks,

Martin

----- Mail original -----
De: "Stef" <[email protected]>
À: "Sane Development" <[email protected]>
Envoyé: Jeudi 11 Juin 2015 21:55:07
Objet: [sane-devel] LiDE 120, small changes pushed in git

      Hello,

      I have pushed some small changes that should improve support for
the LiDE 120 for resolutions up to 600 dpi. Please test this build 2507
of the geneys backend (check this version number in debug logs when
testing).
      Working with some logs sent, then throwing back some code to
someone else to test isn't practical. I don't feel like going on that
way. So people interested by adding support for this model (or another
one) should clone SANE's git tree and syseneg project (which provides a
tool to analyze pcap usb logs), and start hacking it.
      I'd be happy to improve genesys backend's doc to help, and will
gladly apply patches.

Regards,
      Stef

    Hello,

    the backend generates traces when these environment variables are set:
export SANE_DEBUG_GENESYS=255
export SANE_DEBUG_GENESYS_LOW=255
export SANE_DEBUG_GENESYS_GL124=255

then run your frontend from the same command prompt where you typed these commands, for instance you can run scanimage like this:
scanimage -d genesys --resolution 75 --preview --mode Color 2>rl.log >rl.pnm

rl.pnm will be the scan, while rl.log will contain all debug traces.

Regards,
    Stef


--
sane-devel mailing list: [email protected]
http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/sane-devel