On 02/07/2015 17:16, [email protected] wrote:
Hello,
I tested the latest build (SANE Genesys backend version 1.0 build 2507 from
sane-backends 1.0.25 git) on my LIDE 120. Scanner is recognized, stepper motor
are moving but the scan image is 'all black'.
I have set the debug level of Genesys to 255
Any idea what I am doing wrong ?
Thanks,
Martin
Hello,
this model needs more work to really work. It is currently unsupported.
Regards,
Stef
--
sane-devel mailing list: [email protected]
http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/sane-devel
Unsubscribe: Send mail with subject "unsubscribe your_password"
to [email protected]