Hi Erik,
I searched the Technical help database for System z (
https://www14.software.ibm.com/webapp/set2/psearch/search?domain=sysz )
and got plenty of hits for "startio", but none with the term in the
title. If you haven't looked there yet, give it a try and see if
anything looks helpful.
Having done all of this, I would suggest that you start with EXCP and then
progress to EXPC/VR. Even with EXCP you have to know and understand the
relationship of the CCW's you are going to use. Read carefully. Start simple.
Build on it slowly.
Going from EXCP to EXCP/VR is a big jump.
On Sat, 8 Feb 2020 16:31:56 -0500, Phil Smith III wrote:
>
>>How does it handle characters absent from IBM-037?
>
>I expect it will throw an error. This is, as you (Gil) know, one of the
>problems with OP’s query: you can’t stuff thousands of pounds of potatoes into
>a 256-pound sack. (OK,
Gil wrote:
>How does it handle characters absent from IBM-037?
I expect it will throw an error. This is, as you (Gil) know, one of the
problems with OP’s query: you can’t stuff thousands of pounds of potatoes into
a 256-pound sack. (OK, characters, not potatoes.) For those who don’t
Hey Eric:
You might want to start your exploration at a higher level than the
lowest level you can possibly go to understand the internals of z/OS
I/O. For example you might want to look at EXCP or EXCPVR first, as both
prepare for entry into IOS, but both do special setup functions to make
Hello List,
Out of curiosity I want to learn a bit more about startio. Don't worry, I won't
go and attempt to mess up someones z/os lpar, it is just for pure nerd brain
entertainment. Searching through the archives I found that there is a
whitepaper that was written by Peter Haas called "The
On Sat, 8 Feb 2020 09:09:58 -0600, Paul Gilmartin wrote:
>On Sat, 8 Feb 2020 09:37:29 -0500, Cameron Conacher wrote:
>
>>I use ICONV.
>>
>>//MYSTEP EXEC PROC=EDICONV,
>>//INFILE='MY.input.file.name(member)',
>>//OUTFILE='My.Output.FileName',
>>//FROMC='1208',
>>//TOC='IBM-037'
>>
On Sat, 8 Feb 2020 09:37:29 -0500, Cameron Conacher wrote:
>I use ICONV.
>
>//MYSTEP EXEC PROC=EDICONV,
>//INFILE='MY.input.file.name(member)',
>//OUTFILE='My.Output.FileName',
>//FROMC='1208',
>//TOC='IBM-037'
>
>
>The PROC is licensed IBM material. It executes program EDICCONV
>
I use ICONV.
//MYSTEP EXEC PROC=EDICONV,
//INFILE='MY.input.file.name(member)',
//OUTFILE='My.Output.FileName',
//FROMC='1208',
//TOC='IBM-037'
The PROC is licensed IBM material. It executes program EDICCONV
On Thu, Feb 6, 2020 at 9:29 PM Jake Anderson
wrote:
> Hi
>
> Cross
Dave,
After reading the responses for a few days, I think you are getting some
good comments concerning all the long-term issues. I know, I have done
this more than once.
The company I work for has been doing this for about 30 years.
We first take the customer to our floor, then we migrate
10 matches
Mail list logo