Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
i hate that chuck is open about product flaws and offers troubleshooting ideas, he pawns all the guild off on us for never having the time On Sat, Jun 9, 2018 at 6:55 PM Chuck McCown wrote: > Surge suppressors can certainly cause this. > > Sent from my iPhone > > > On Jun 9, 2018, at 2:58 PM, George Skorup > wrote: > > > > What suppressors? > > > >> On 6/9/2018 3:23 PM, Jason McKemie wrote: > >> I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS > errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, > the Rx FCS errors stop, but Rx Code errors start incrementing instead. > I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, > but not nearly this many. It's starting to have an effect on service on > the sector. > >> > >> Any ideas what I should look at? Some people were claiming that > putting something like a Netonix in between the Mimosa and the Mikrotik > solved their issues, but I'm wondering if the surge suppressors are > creating an issue as well. > >> > >> -Jason > > >
Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
It was definitely the surge suppressor. I took the one out of in-line at the bottom and errors went away. I had tried to put one up top, but couldn't get the A5 to even power up with it inline, so there isn't one present up there anyhow. Now, how do I determine which version I'm getting? I have a few of the earlier versions sitting around that it appears are not going to work well for this application. Strangely, I have a Ceragon running gigabit through the same version with no problems at all. -Jason On Sat, Jun 9, 2018 at 6:55 PM, Chuck McCown wrote: > Surge suppressors can certainly cause this. > > Sent from my iPhone > > > On Jun 9, 2018, at 2:58 PM, George Skorup > wrote: > > > > What suppressors? > > > >> On 6/9/2018 3:23 PM, Jason McKemie wrote: > >> I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS > errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, > the Rx FCS errors stop, but Rx Code errors start incrementing instead. > I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, > but not nearly this many. It's starting to have an effect on service on > the sector. > >> > >> Any ideas what I should look at? Some people were claiming that > putting something like a Netonix in between the Mimosa and the Mikrotik > solved their issues, but I'm wondering if the surge suppressors are > creating an issue as well. > >> > >> -Jason > > >
Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
Surge suppressors can certainly cause this. Sent from my iPhone > On Jun 9, 2018, at 2:58 PM, George Skorup wrote: > > What suppressors? > >> On 6/9/2018 3:23 PM, Jason McKemie wrote: >> I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS errors >> on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, the Rx >> FCS errors stop, but Rx Code errors start incrementing instead. I've always >> gotten some amount of Rx FCS errors from Mimosa A5/A5C units, but not nearly >> this many. It's starting to have an effect on service on the sector. >> >> Any ideas what I should look at? Some people were claiming that putting >> something like a Netonix in between the Mimosa and the Mikrotik solved their >> issues, but I'm wondering if the surge suppressors are creating an issue as >> well. >> >> -Jason >
Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
The easiest way to tell is obviously to take the SS out and see if the errors stop. And as Chuck has said in the past, an SS can get wounded. Definitely seen that. In fact, just the other day I had two 450 sectors with link losses, falling back to 10Mbps, etc. and quite a lot of errors. Took the Rev D SS's out and the errors were gone. Replaced them with new Rev E's I happened to have in my truck and they're running fine (100Mbps and Canopy sync). The Rev D's did their job. On 6/9/2018 4:42 PM, Jason McKemie wrote: They are Chuck's suppressors and I'm pretty sure they are an older revision as well, so that could be a contributing factor. On Sat, Jun 9, 2018 at 4:14 PM, George Skorup mailto:george.sko...@cbcast.com>> wrote: Guess I should correct my grammar and say which suppressor(s)? And follow that up with the assumption that you're using Chuck's suppressors? The only one that produced no errors for me is the CAT6-APC which is just gas tubes, no diodes. He asked me to test one more thing with the Rev G GigE-APC, but I just haven't had the time to get out to a site and do it. I am using some Rev D and E GigE-APCs on Canopy and ePMP at 100Mbps and sync pulses present and those work fine. Gigabit is the real pain in the ass. Gigabit + Canopy sync is even more of a pain in the ass. I've got old Rev A (or B? I don't remember) GigE-APCs and GigE-POE-APCs that work fine at gigabit and no sync pulse, mostly AirFibers and some Exalt radios on those. The CAT6-APC is probably what we'll move forward with for everything since it'll be the most universal and offer decent protection. Actually probably better than decent. I think Chuck said the clamp voltage is around 90-100 volts. The cheap stuff might die, but it's cheap so who cares. On 6/9/2018 3:58 PM, George Skorup wrote: What suppressors? On 6/9/2018 3:23 PM, Jason McKemie wrote: I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, the Rx FCS errors stop, but Rx Code errors start incrementing instead. I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, but not nearly this many. It's starting to have an effect on service on the sector. Any ideas what I should look at? Some people were claiming that putting something like a Netonix in between the Mimosa and the Mikrotik solved their issues, but I'm wondering if the surge suppressors are creating an issue as well. -Jason
Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
They are Chuck's suppressors and I'm pretty sure they are an older revision as well, so that could be a contributing factor. On Sat, Jun 9, 2018 at 4:14 PM, George Skorup wrote: > Guess I should correct my grammar and say which suppressor(s)? > > And follow that up with the assumption that you're using Chuck's > suppressors? The only one that produced no errors for me is the CAT6-APC > which is just gas tubes, no diodes. He asked me to test one more thing with > the Rev G GigE-APC, but I just haven't had the time to get out to a site > and do it. > > I am using some Rev D and E GigE-APCs on Canopy and ePMP at 100Mbps and > sync pulses present and those work fine. Gigabit is the real pain in the > ass. Gigabit + Canopy sync is even more of a pain in the ass. I've got old > Rev A (or B? I don't remember) GigE-APCs and GigE-POE-APCs that work fine > at gigabit and no sync pulse, mostly AirFibers and some Exalt radios on > those. > > The CAT6-APC is probably what we'll move forward with for everything since > it'll be the most universal and offer decent protection. Actually probably > better than decent. I think Chuck said the clamp voltage is around 90-100 > volts. The cheap stuff might die, but it's cheap so who cares. > > > On 6/9/2018 3:58 PM, George Skorup wrote: > >> What suppressors? >> >> On 6/9/2018 3:23 PM, Jason McKemie wrote: >> >>> I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS >>> errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, >>> the Rx FCS errors stop, but Rx Code errors start incrementing instead. >>> I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, >>> but not nearly this many. It's starting to have an effect on service on >>> the sector. >>> >>> Any ideas what I should look at? Some people were claiming that putting >>> something like a Netonix in between the Mimosa and the Mikrotik solved >>> their issues, but I'm wondering if the surge suppressors are creating an >>> issue as well. >>> >>> -Jason >>> >> >> >
Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
Guess I should correct my grammar and say which suppressor(s)? And follow that up with the assumption that you're using Chuck's suppressors? The only one that produced no errors for me is the CAT6-APC which is just gas tubes, no diodes. He asked me to test one more thing with the Rev G GigE-APC, but I just haven't had the time to get out to a site and do it. I am using some Rev D and E GigE-APCs on Canopy and ePMP at 100Mbps and sync pulses present and those work fine. Gigabit is the real pain in the ass. Gigabit + Canopy sync is even more of a pain in the ass. I've got old Rev A (or B? I don't remember) GigE-APCs and GigE-POE-APCs that work fine at gigabit and no sync pulse, mostly AirFibers and some Exalt radios on those. The CAT6-APC is probably what we'll move forward with for everything since it'll be the most universal and offer decent protection. Actually probably better than decent. I think Chuck said the clamp voltage is around 90-100 volts. The cheap stuff might die, but it's cheap so who cares. On 6/9/2018 3:58 PM, George Skorup wrote: What suppressors? On 6/9/2018 3:23 PM, Jason McKemie wrote: I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, the Rx FCS errors stop, but Rx Code errors start incrementing instead. I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, but not nearly this many. It's starting to have an effect on service on the sector. Any ideas what I should look at? Some people were claiming that putting something like a Netonix in between the Mimosa and the Mikrotik solved their issues, but I'm wondering if the surge suppressors are creating an issue as well. -Jason
Re: [AFMUG] Mikrotik / Mimosa Ethernet Errors
What suppressors? On 6/9/2018 3:23 PM, Jason McKemie wrote: I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, the Rx FCS errors stop, but Rx Code errors start incrementing instead. I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, but not nearly this many. It's starting to have an effect on service on the sector. Any ideas what I should look at? Some people were claiming that putting something like a Netonix in between the Mimosa and the Mikrotik solved their issues, but I'm wondering if the surge suppressors are creating an issue as well. -Jason
[AFMUG] Mikrotik / Mimosa Ethernet Errors
I have a A5C that is giving me grief. I'm getting hundreds of Rx FCS errors on the Mikrotik when I'm running gigabit, if I force it to 100 fdx, the Rx FCS errors stop, but Rx Code errors start incrementing instead. I've always gotten some amount of Rx FCS errors from Mimosa A5/A5C units, but not nearly this many. It's starting to have an effect on service on the sector. Any ideas what I should look at? Some people were claiming that putting something like a Netonix in between the Mimosa and the Mikrotik solved their issues, but I'm wondering if the surge suppressors are creating an issue as well. -Jason