Re: VAXstation 4000/90 Diagnostics

2021-05-23 Thread Zane Healy via cctalk
On May 23, 2021, at 10:37 AM, emanuel stiebler  wrote:
> 
> On 2021-05-21 16:38, Zane Healy via cctalk wrote:
>> Is anyone familiar with the 4000/90 diagnostics?  It looks like it will fail 
>> the test of the LCSPX graphics board, if it’s not plugged into a monitor, or 
>> is missing a loopback device. Is that correct?
>> 
>> T 2 fails, but the manual makes it sound like I need a loopback
> 
> IIRC, it is normal that it fails, without a monitor attached.
> Did you try to switch to serial console, if it still complains?

I suspected that was the case.  I’m currently only on a serial console, until I 
solve my monitor cable problems.

>> T 100 succeeds when testing the LCSPX graphics board.
> If you have amonitor attached, you would see some colors flipping and
> some drawing being made on the screen

Once I get a monitor attached, I plan to run it through the full screen 
diagnostics.

>> The system had been a boat anchor until a short time ago, as the battery in 
>> the Dallas DS1287A RTC was dead.  Amazon just delivered two DS12887’s.  Once 
>> I replaced it, it came right up.  I was surprised to see I had a 4GB and a 
>> 2GB drive in it.
> 
> Which ones did you get? (source?)
> Have to fix another two in the near future …

DS12887+ from Amazon.  

>> Now to dig out the mouse, and wait for the parts to hook it up to a monitor. 
>> :-)
> 
> Yes, the monitor cable is fun to look for …

I should have a monitor cable by Thursday, assuming I don’t find the one that 
I’m sure I have before that.  Since I’ve been searching for the cable for 
several months, I decided to buy one off eBay, and I have the parts I should 
need to hook it up to a modern monitor.  Wow!  FedEx just delivered the cable, 
so I guess I’ll be hooking it up shortly.  It looks brand new.

When I dug back to the mice, I found I have two VSXXX-AA hockey puck mice, so 
I’m even more convinced that I have a monitor cable somewhere.  I also found a 
AUI loopback with the mice.

The next part I need is a C15 power cable for MicroVAX 3300, I’ll see about 
picking that up tomorrow or Wednesday.  I don’t believe that I’ve ever tested 
the MicroVAX 3300.  A friend gave it to me when he was moving out of his 
apartment.  Given that it’s only 2.4 VUPS, I can’t see me doing anything with 
it at this point.  I should also test my MicroVAX III while I’m at this.

Zane





Re: VAXstation 4000/90 Diagnostics

2021-05-23 Thread emanuel stiebler via cctalk
On 2021-05-21 16:38, Zane Healy via cctalk wrote:
> Is anyone familiar with the 4000/90 diagnostics?  It looks like it will fail 
> the test of the LCSPX graphics board, if it’s not plugged into a monitor, or 
> is missing a loopback device. Is that correct?
> 
> T 2 fails, but the manual makes it sound like I need a loopback

IIRC, it is normal that it fails, without a monitor attached.
Did you try to switch to serial console, if it still complains?
> T 100 succeeds when testing the LCSPX graphics board.
If you have amonitor attached, you would see some colors flipping and
some drawing being made on the screen
> 
> The system had been a boat anchor until a short time ago, as the battery in 
> the Dallas DS1287A RTC was dead.  Amazon just delivered two DS12887’s.  Once 
> I replaced it, it came right up.  I was surprised to see I had a 4GB and a 
> 2GB drive in it.

Which ones did you get? (source?)
Have to fix another two in the near future ...
> 
> Now to dig out the mouse, and wait for the parts to hook it up to a monitor. 
> :-)

Yes, the monitor cable is fun to look for ...

Cheers!