[Desktop-packages] [Bug 1896785] Re: Exported DBus interface is missing info or using wrong names
This bug was fixed in the package gnome-shell-extension-appindicator - 33.1-0ubuntu0.20.04.1 --- gnome-shell-extension-appindicator (33.1-0ubuntu0.20.04.1) focal; urgency=medium [ Marco Trevisan (Treviño) ] * New upstream stable release * debian/gbp.conf: - Setup for focal branching and use ubuntu/* tagging - Use multimaint-merge in dch and sign tags * debian/control: - Set Ubuntu Developers as maintainer - Update VCS informations to point to ubuntu/focal * dbusMenu: Use GCancellable to stop pending async operations (LP: #1881669) * dbusMenu: Use proper argument name when parsing error (LP: #1881669) * dbusMenu: Stop idle requests if we've been destroyed (LP: #1870795) * appIndicator: Remove the callbackIdle if we destroy while waiting it (LP: #1849142) * StatusNotifierWatcher: Remove ProtocolVersion method (LP: #1896785) * appIndicator: Ignore further icons creation during an idle (LP: #1849142) * README: Remove statement about indicator-multiload not being supported * statusNotifierWatcher: Fix RegisterStatusNotifierHost method name and returned error (LP: #1896785) * interfaces: Sync interfaces XML with upstream ones (LP: #1896785) * StatusNotifierItem: Disable Tooltip properties and signals (LP: #1896785) * appIndicator: Don't waste CPU cycles to handle icon updates (LP: #1884396): - util: Use Shell's param to handle multiple named arguments - util: Delete proxyCancellables only if we didn't cancel already - util: Ignore errors if we can't find a listed dbus name - appIndicator: Cleanup the interface info properties map computation - appIndicator: Don't deep unpack changed properties array - appIndicator: Use native checks to look for equal emblems - appIndicator: Mark a valid cached icon as inUse again - appIndicator: Correctly mark cached GIcon's as in use - iconCache: Rewrite simplifying the usage for GIcon's only - iconCache: Dispose an icon when we remove it - iconCache: Increase the garbage-collector timings - appIndicator: Only iterate through the proxy available properties - appIndicator: Don't try to check equality on Pixmap variants - util: Try to batch properties updates when they comes close enough - appIndicator: Accumulate signals to batch close updates - appIndicator: Emit the same signal once on properties updates - appIndicator: Improve the warning message on lookup failed [ Fini Jastrow ] * appIndicator: Remove unneeded padding (LP: #1896779) * appIndicator: Fix 'reduce padding' for some icons (LP: #1896779) [ Sergio Costas ] * Wait until the desktop ends starting up (LP: #1870795) * Wait until Gtk.IconTheme.get_default() works (LP: #1870795) * Don't fail if no icon is found (LP: #1849142) * Use signal to detect display availability (LP: #1870795) [ Tasos Sahanidis ] * kstatusnotifierwatcher: Implement ProtocolVersion property (LP: #1896785) -- Marco Trevisan (Treviño) Wed, 23 Sep 2020 18:47:33 +0200 ** Changed in: gnome-shell-extension-appindicator (Ubuntu Focal) Status: Fix Committed => Fix Released -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to gnome-shell-extension-appindicator in Ubuntu. https://bugs.launchpad.net/bugs/1896785 Title: Exported DBus interface is missing info or using wrong names Status in gnome-shell-extension-appindicator package in Ubuntu: Fix Released Status in gnome-shell-extension-appindicator source package in Focal: Fix Released Bug description: [ Impact ] GNOME shell when using this indicator should export the org.kde.StatusNotifierWatcher dbus interface, although some methods and properties are missing or invalid [ Test case ] Run: gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion -> Should return (<0>,) In particular, the API should contain gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher node /StatusNotifierWatcher { Default fdo properties stuff interface org.kde.StatusNotifierWatcher { interface org.kde.StatusNotifierWatcher { methods: RegisterStatusNotifierItem(in s service); RegisterStatusNotifierHost(in s service); signals: StatusNotifierItemRegistered(s arg_0); StatusNotifierItemUnregistered(s arg_0); StatusNotifierHostRegistered(); StatusNotifierHostUnregistered(); properties: @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; readonly b IsStatusNotifierHostRegistered = true; readonly i ProtocolVersion = 0; }; }; In the old version we had an invalid "RegisterNotificationHost" method (not
[Desktop-packages] [Bug 1896785] Re: Exported DBus interface is missing info or using wrong names
❯ apt-cache policy gnome-shell-extension-appindicator gnome-shell-extension-appindicator: Installato: 33.1-0ubuntu0.20.04.1 Candidato: 33.1-0ubuntu0.20.04.1 Tabella versione: *** 33.1-0ubuntu0.20.04.1 400 400 http://archive.ubuntu.com/ubuntu focal-proposed/main amd64 Packages 400 http://archive.ubuntu.com/ubuntu focal-proposed/main i386 Packages 100 /var/lib/dpkg/status 33-1 500 500 http://archive.ubuntu.com/ubuntu focal/main amd64 Packages 500 http://archive.ubuntu.com/ubuntu focal/main i386 Packages ❯ gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion (<0>,) ** Tags removed: verification-needed verification-needed-focal ** Tags added: verification-done verification-done-focal -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to gnome-shell-extension-appindicator in Ubuntu. https://bugs.launchpad.net/bugs/1896785 Title: Exported DBus interface is missing info or using wrong names Status in gnome-shell-extension-appindicator package in Ubuntu: Fix Released Status in gnome-shell-extension-appindicator source package in Focal: Fix Committed Bug description: [ Impact ] GNOME shell when using this indicator should export the org.kde.StatusNotifierWatcher dbus interface, although some methods and properties are missing or invalid [ Test case ] Run: gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion -> Should return (<0>,) In particular, the API should contain gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher node /StatusNotifierWatcher { Default fdo properties stuff interface org.kde.StatusNotifierWatcher { interface org.kde.StatusNotifierWatcher { methods: RegisterStatusNotifierItem(in s service); RegisterStatusNotifierHost(in s service); signals: StatusNotifierItemRegistered(s arg_0); StatusNotifierItemUnregistered(s arg_0); StatusNotifierHostRegistered(); StatusNotifierHostUnregistered(); properties: @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; readonly b IsStatusNotifierHostRegistered = true; readonly i ProtocolVersion = 0; }; }; In the old version we had an invalid "RegisterNotificationHost" method (not specified by specs nor used) We didn't expose the ProtocolVersion --- [ Regression potential ] We won't expose anymore some NON-STANDARD and NEVER USED dbus methods such as: - RegisterNotificationHost (was un-implemlented anyways) - ProtocolVersion (this was supposed to be a property, not a method) There are some changes to the interfaces xml files to follow the standard ones, but they don't involve any change, could happen though that we don't list a property that an indicator exposes lazily (don't think there are in real world). To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/gnome-shell-extension-appindicator/+bug/1896785/+subscriptions -- Mailing list: https://launchpad.net/~desktop-packages Post to : desktop-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~desktop-packages More help : https://help.launchpad.net/ListHelp
[Desktop-packages] [Bug 1896785] Re: Exported DBus interface is missing info or using wrong names
Hello Marco, or anyone else affected, Accepted gnome-shell-extension-appindicator into focal-proposed. The package will build now and be available at https://launchpad.net/ubuntu/+source/gnome-shell-extension- appindicator/33.1-0ubuntu0.20.04.1 in a few hours, and then in the -proposed repository. Please help us by testing this new package. See https://wiki.ubuntu.com/Testing/EnableProposed for documentation on how to enable and use -proposed. Your feedback will aid us getting this update out to other Ubuntu users. If this package fixes the bug for you, please add a comment to this bug, mentioning the version of the package you tested, what testing has been performed on the package and change the tag from verification-needed- focal to verification-done-focal. If it does not fix the bug for you, please add a comment stating that, and change the tag to verification- failed-focal. In either case, without details of your testing we will not be able to proceed. Further information regarding the verification process can be found at https://wiki.ubuntu.com/QATeam/PerformingSRUVerification . Thank you in advance for helping! N.B. The updated package will be released to -updates after the bug(s) fixed by this package have been verified and the package has been in -proposed for a minimum of 7 days. ** Changed in: gnome-shell-extension-appindicator (Ubuntu Focal) Status: New => Fix Committed ** Tags added: verification-needed verification-needed-focal -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to gnome-shell-extension-appindicator in Ubuntu. https://bugs.launchpad.net/bugs/1896785 Title: Exported DBus interface is missing info or using wrong names Status in gnome-shell-extension-appindicator package in Ubuntu: Fix Released Status in gnome-shell-extension-appindicator source package in Focal: Fix Committed Bug description: [ Impact ] GNOME shell when using this indicator should export the org.kde.StatusNotifierWatcher dbus interface, although some methods and properties are missing or invalid [ Test case ] Run: gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion -> Should return (<0>,) In particular, the API should contain gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher node /StatusNotifierWatcher { Default fdo properties stuff interface org.kde.StatusNotifierWatcher { interface org.kde.StatusNotifierWatcher { methods: RegisterStatusNotifierItem(in s service); RegisterStatusNotifierHost(in s service); signals: StatusNotifierItemRegistered(s arg_0); StatusNotifierItemUnregistered(s arg_0); StatusNotifierHostRegistered(); StatusNotifierHostUnregistered(); properties: @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; readonly b IsStatusNotifierHostRegistered = true; readonly i ProtocolVersion = 0; }; }; In the old version we had an invalid "RegisterNotificationHost" method (not specified by specs nor used) We didn't expose the ProtocolVersion --- [ Regression potential ] We won't expose anymore some NON-STANDARD and NEVER USED dbus methods such as: - RegisterNotificationHost (was un-implemlented anyways) - ProtocolVersion (this was supposed to be a property, not a method) There are some changes to the interfaces xml files to follow the standard ones, but they don't involve any change, could happen though that we don't list a property that an indicator exposes lazily (don't think there are in real world). To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/gnome-shell-extension-appindicator/+bug/1896785/+subscriptions -- Mailing list: https://launchpad.net/~desktop-packages Post to : desktop-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~desktop-packages More help : https://help.launchpad.net/ListHelp
[Desktop-packages] [Bug 1896785] Re: Exported DBus interface is missing info or using wrong names
** Description changed: [ Impact ] GNOME shell when using this indicator should export the org.kde.StatusNotifierWatcher dbus interface, although some methods and properties are missing or invalid - [ Test case ] - Run: - gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ - --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion + gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ + --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion -> Should return (<0>,) In particular, the API should contain - gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher + gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher node /StatusNotifierWatcher { - - Default fdo properties stuff - interface org.kde.StatusNotifierWatcher { - interface org.kde.StatusNotifierWatcher { - methods: - RegisterStatusNotifierItem(in s service); - RegisterStatusNotifierHost(in s service); - signals: - StatusNotifierItemRegistered(s arg_0); - StatusNotifierItemUnregistered(s arg_0); - StatusNotifierHostRegistered(); - StatusNotifierHostUnregistered(); - properties: - @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") - readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; - readonly b IsStatusNotifierHostRegistered = true; - readonly i ProtocolVersion = 0; - }; + Default fdo properties stuff + + interface org.kde.StatusNotifierWatcher { + interface org.kde.StatusNotifierWatcher { + methods: + RegisterStatusNotifierItem(in s service); + RegisterStatusNotifierHost(in s service); + signals: + StatusNotifierItemRegistered(s arg_0); + StatusNotifierItemUnregistered(s arg_0); + StatusNotifierHostRegistered(); + StatusNotifierHostUnregistered(); + properties: + @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") + readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; + readonly b IsStatusNotifierHostRegistered = true; + readonly i ProtocolVersion = 0; + }; }; - In the old version we had an invalid "RegisterNotificationHost" method (not specified by specs nor used) We didn't expose the ProtocolVersion + + --- + + [ Regression potential ] + + We won't expose anymore some NON-STANDARD and NEVER USED dbus methods such as: + - RegisterNotificationHost (was un-implemlented anyways) + - ProtocolVersion (this was supposed to be a property, not a method) + + There are some changes to the interfaces xml files to follow the + standard ones, but they don't involve any change, could happen though + that we don't list a property that an indicator exposes lazily (don't + think there are in real world). -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to gnome-shell-extension-appindicator in Ubuntu. https://bugs.launchpad.net/bugs/1896785 Title: Exported DBus interface is missing info or using wrong names Status in gnome-shell-extension-appindicator package in Ubuntu: Fix Released Bug description: [ Impact ] GNOME shell when using this indicator should export the org.kde.StatusNotifierWatcher dbus interface, although some methods and properties are missing or invalid [ Test case ] Run: gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion -> Should return (<0>,) In particular, the API should contain gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher node /StatusNotifierWatcher { Default fdo properties stuff interface org.kde.StatusNotifierWatcher { interface org.kde.StatusNotifierWatcher { methods: RegisterStatusNotifierItem(in s service); RegisterStatusNotifierHost(in s service); signals: StatusNotifierItemRegistered(s arg_0); StatusNotifierItemUnregistered(s arg_0); StatusNotifierHostRegistered(); StatusNotifierHostUnregistered(); properties: @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; readonly b IsStatusNotifierHostRegistered = true; readonly i ProtocolVersion = 0; }; }; In the old version we had an invalid "RegisterNotificationHost" method (not specified by specs nor used) We didn't expose the ProtocolVersion --- [ Regression potential ] We won't expose anymore some NON-STANDARD and NEVER USED dbus methods such as: -
[Desktop-packages] [Bug 1896785] Re: Exported DBus interface is missing info or using wrong names
This has been fixed in 34-1 -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to gnome-shell-extension-appindicator in Ubuntu. https://bugs.launchpad.net/bugs/1896785 Title: Exported DBus interface is missing info or using wrong names Status in gnome-shell-extension-appindicator package in Ubuntu: Fix Released Bug description: [ Impact ] GNOME shell when using this indicator should export the org.kde.StatusNotifierWatcher dbus interface, although some methods and properties are missing or invalid [ Test case ] Run: gdbus call --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher \ --method org.freedesktop.DBus.Properties.Get "org.kde.StatusNotifierWatcher" ProtocolVersion -> Should return (<0>,) In particular, the API should contain gdbus introspect --session --dest org.gnome.Shell --object-path /StatusNotifierWatcher node /StatusNotifierWatcher { Default fdo properties stuff interface org.kde.StatusNotifierWatcher { interface org.kde.StatusNotifierWatcher { methods: RegisterStatusNotifierItem(in s service); RegisterStatusNotifierHost(in s service); signals: StatusNotifierItemRegistered(s arg_0); StatusNotifierItemUnregistered(s arg_0); StatusNotifierHostRegistered(); StatusNotifierHostUnregistered(); properties: @org.qtproject.QtDBus.QtTypeName.Out0("QStringList") readonly as RegisteredStatusNotifierItems = [ ... list of indicators path/obj-names ... ]; readonly b IsStatusNotifierHostRegistered = true; readonly i ProtocolVersion = 0; }; }; In the old version we had an invalid "RegisterNotificationHost" method (not specified by specs nor used) We didn't expose the ProtocolVersion --- [ Regression potential ] We won't expose anymore some NON-STANDARD and NEVER USED dbus methods such as: - RegisterNotificationHost (was un-implemlented anyways) - ProtocolVersion (this was supposed to be a property, not a method) There are some changes to the interfaces xml files to follow the standard ones, but they don't involve any change, could happen though that we don't list a property that an indicator exposes lazily (don't think there are in real world). To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/gnome-shell-extension-appindicator/+bug/1896785/+subscriptions -- Mailing list: https://launchpad.net/~desktop-packages Post to : desktop-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~desktop-packages More help : https://help.launchpad.net/ListHelp