Re: [Elecraft] KPA500 Bypass Power Limit?

2020-12-26 Thread Lyn Norstad
My KPA500 goes into PASS-THROUGH mode when the Power is set to Off, or the 
power is On but the unit is in Standby.  It does not process the signal in any 
way, merely acknowledges its presence.  It does not have a Bypass mode.  In 
order to Bypass it, I need to move a couple of cables.

My KAT500, however, does have a BYPASS mode in which it measures the SWR and 
makes a decision on whether or not to provide any additional processing, other 
than routing it to the preferred ANTENNA, based on my indicated preferences.

73.0
Lyn, W0LEN

-Original Message-
From: elecraft-boun...@mailman.qth.net 
[mailto:elecraft-boun...@mailman.qth.net] On Behalf Of Jim Brown
Sent: Saturday, December 26, 2020 1:55 AM
To: elecraft@mailman.qth.net
Subject: Re: [Elecraft] KPA500 Bypass Power Limit?

On 12/25/2020 7:12 PM, Andy Durbin wrote:
> KPA500 has no "BYPASS" mode.  It is either Off, On in STBY, or On in OPER.

Picky, picky, picky. :) When all of the power amps I'm aware of are in a 
mode usually called "Standby," meaning that they are powered up and 
ready to transmit, but are Bypassed. they are Bypassed. They are also 
Bypassed when turned off. And when tube amps are prevented from 
transmitting when their filaments are warming up, they are Bypassed.

73, Jim K9YC






__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to l...@lnainc.com 

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 


Re: [Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread Jim Brown

On 12/25/2020 7:12 PM, Andy Durbin wrote:

KPA500 has no "BYPASS" mode.  It is either Off, On in STBY, or On in OPER.


Picky, picky, picky. :) When all of the power amps I'm aware of are in a 
mode usually called "Standby," meaning that they are powered up and 
ready to transmit, but are Bypassed. they are Bypassed. They are also 
Bypassed when turned off. And when tube amps are prevented from 
transmitting when their filaments are warming up, they are Bypassed.


73, Jim K9YC






__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Re: [Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread Adrian
There was no question regarding if the amp had a bypass 'mode' It was as 
you quoted;


"How much power can I run through a KPA500 that is in BYPASS"

So in 'standby' mode the amp is 'in bypass' as its input is connected to its 
output.

So it seems an unnecessary invalid initial answer to a question that did not 
exist regarding bypass mode.

However ;

"You may run up to 200 watts through the KPA500 in STBY." was on the money.


On 26/12/20 1:12 pm, Andy Durbin wrote:

"How much power can I run through a KPA500 that is in BYPASS"

KPA500 has no "BYPASS" mode.  It is either Off, On in STBY, or On in OPER.

The  KPA500 Owner's Manual says - "Transmitting - The POWER (W) and standing wave 
ratio (SWR) bargraphs are functional when the amplifier is in standby (STBY). Twenty-five 
watts from the driving transceiver will illuminate the first POWER LED. You may run up to 
200 watts through the KPA500 in STBY."

The answer to your question would appear to be "200 W".

73,
Andy k3wyc

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to vk4...@gmail.com

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

[Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread Andy Durbin
"How much power can I run through a KPA500 that is in BYPASS"

KPA500 has no "BYPASS" mode.  It is either Off, On in STBY, or On in OPER.

The  KPA500 Owner's Manual says - "Transmitting - The POWER (W) and standing 
wave ratio (SWR) bargraphs are functional when the amplifier is in standby 
(STBY). Twenty-five watts from the driving transceiver will illuminate the 
first POWER LED. You may run up to 200 watts through the KPA500 in STBY."

The answer to your question would appear to be "200 W".

73,
Andy k3wyc

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 


Re: [Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread Harry Yingst via Elecraft
 as per the manual

"You may run up to 100 watts through the KPA500 in STBY."




On Friday, December 25, 2020, 08:01:49 PM EST, eric norris via Elecraft 
 wrote:  
 
 How much power can I run through a KPA500 that is in BYPASS, or turned off?  
That is, using exciter power only?
Thanks!

73, Eric WD6DBM

 
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to hlyin...@yahoo.com   
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Re: [Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread Eric Norris
200-250w if it's safe.

73 Eric WD6DBM

On Fri, Dec 25, 2020, 6:28 PM Michael Walker  wrote:

> Hi Eric
>
> A 100 watts works without issue.
>
> What sort of power did you have in mind?
>
> Mike
>
>
> On Fri, Dec 25, 2020 at 8:01 PM eric norris via Elecraft <
> elecraft@mailman.qth.net> wrote:
>
> > How much power can I run through a KPA500 that is in BYPASS, or turned
> > off?  That is, using exciter power only?
> > Thanks!
> >
> > 73, Eric WD6DBM
> >
> > 
> > __
> > Elecraft mailing list
> > Home: http://mailman.qth.net/mailman/listinfo/elecraft
> > Help: http://mailman.qth.net/mmfaq.htm
> > Post: mailto:Elecraft@mailman.qth.net
> >
> > This list hosted by: http://www.qsl.net
> > Please help support this email list: http://www.qsl.net/donate.html
> > Message delivered to va...@portcredit.net
> __
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to norrislawfi...@gmail.com
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Re: [Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread Michael Walker
Hi Eric

A 100 watts works without issue.

What sort of power did you have in mind?

Mike


On Fri, Dec 25, 2020 at 8:01 PM eric norris via Elecraft <
elecraft@mailman.qth.net> wrote:

> How much power can I run through a KPA500 that is in BYPASS, or turned
> off?  That is, using exciter power only?
> Thanks!
>
> 73, Eric WD6DBM
>
> 
> __
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to va...@portcredit.net
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

[Elecraft] KPA500 Bypass Power Limit?

2020-12-25 Thread eric norris via Elecraft
How much power can I run through a KPA500 that is in BYPASS, or turned off?  
That is, using exciter power only?
Thanks!

73, Eric WD6DBM

 
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com