FreeBSD and UPS

2009-03-06 Thread Pieter Donche

The vendor of our new server, tells me that an APC Smart-UPS 2200VA
or APC Smart-UPS 3000VA does not have software for automatic shutdown when 
power is lost, which is compatible with FreeBSD, it is only compatible 
with Windows and Linux.


Is this true? Has someone experience with that?
___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org


Re: FreeBSD and UPS

2009-03-06 Thread Bill Moran
In response to Pieter Donche pieter.don...@ua.ac.be:

 The vendor of our new server, tells me that an APC Smart-UPS 2200VA
 or APC Smart-UPS 3000VA does not have software for automatic shutdown when 
 power is lost, which is compatible with FreeBSD, it is only compatible 
 with Windows and Linux.
 
 Is this true? Has someone experience with that?

It's probably true.  However, just because APC doesn't supply software
officially supported by FreeBSD, doesn't mean that it doesn't exist.

I've had good success with ports/sysutils/apcupsd/

-- 
Bill Moran
http://www.potentialtech.com
http://people.collaborativefusion.com/~wmoran/
___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org


Re: FreeBSD and UPS

2009-03-06 Thread bsd

Yes !

There is a very good soft called apcupsd.

I am working in Angola and have had a lot of problems with  
electricity // until I have discovered this soft.
It works perfectly with the apc network card (It came as an option on  
my APC 1500).


I have setup apcupsd to use snmp (this seems to be the most stable use).


I was very surprised because the soft did shutdown the server  
automatically when the UPS went out of battery… and I had not tested  
that (lack of time).

So the soft even went beyond my expectations…


Port:   apcupsd-3.14.5
Path:   /usr/ports/sysutils/apcupsd
Info:   Set of programs for controlling APC UPS
Maint:  ite...@freebsd.org
B-deps:	gettext-0.17_1 gmake-3.81_3 libiconv-1.11_1 net-snmp-5.4.2.1_2  
perl-5.8.9_2

R-deps: net-snmp-5.4.2.1_2 perl-5.8.9_2
WWW:http://www.apcupsd.com



Le 6 mars 09 à 16:04, Pieter Donche a écrit :


The vendor of our new server, tells me that an APC Smart-UPS 2200VA
or APC Smart-UPS 3000VA does not have software for automatic  
shutdown when power is lost, which is compatible with FreeBSD, it is  
only compatible with Windows and Linux.


Is this true? Has someone experience with that?
___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org 




Gregober --- PGP ID -- 0x1BA3C2FD
bsd @at@ todoo.biz


P Please consider your environmental responsibility before printing  
this e-mail



___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org


Re: FreeBSD and UPS

2009-03-06 Thread Wojciech Puchar

install apcupsd from ports

On Fri, 6 Mar 2009, Pieter Donche wrote:


The vendor of our new server, tells me that an APC Smart-UPS 2200VA
or APC Smart-UPS 3000VA does not have software for automatic shutdown when 
power is lost, which is compatible with FreeBSD, it is only compatible with 
Windows and Linux.


Is this true? Has someone experience with that?
___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org



___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org


Re: FreeBSD and UPS

2009-03-06 Thread Wojciech Puchar


I am working in Angola and have had a lot of problems with electricity // 
until I have discovered this soft.
It works perfectly with the apc network card (It came as an option on my APC 
1500).


I have setup apcupsd to use snmp (this seems to be the most stable use).


I was very surprised because the soft did shutdown the server automatically 
when the UPS went out of battery? and I had not tested that (lack of time).

So the soft even went beyond my expectations?



it is important too to make sure BIOS settings are set to automatically 
power up computer when power is present.


by default it will not until you press a button
___
freebsd-questions@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to freebsd-questions-unsubscr...@freebsd.org