Re: [gmx-users] K+ ions instead of NA+ for neutralization
Hi. I'm new to simulation and haven't tried that. Below is what I heard. Most of the time, the force field just treat K+ and Na+ as a sphere with charge and with no orbitals. So, K+ and Na+ ions in simulations are only different in radius (of the sphere). I guess it is ok to use K+ instead of Na+. What forcefield did you use? On Sun, Sep 13, 2015 at 3:10 AM, Andrew Bostickwrote: > Dear gromacs users, > > For neutralizing the simulation system, can I use K+ ions instead of NA+? > > Best, > Andrew > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] calculation of persistence length
Hi. I guess g_polystat can't do that. The online reference for gmx polystat (( http://manual.gromacs.org/programs/gmx-polystat.html) says: "...the persistence length is defined as number of bonds where the average cos reaches a value of 1/e." The number of bonds is one number. I don't think it is possible to recover the many cos(theta) used to calculate this number of bonds. How about g_angle? (http://www.cenapad.unicamp.br/parque/manuais/Gromacs/online/g_angle.html) (http://manual.gromacs.org/programs/gmx-angle.html) On Sat, Sep 12, 2015 at 2:33 AM, soumadwip ghoshwrote: > Dear all, > I want to calculate the persistence length of a single stranded > DNA in the presence of various salts. I want to plot a lnP(theta) vs > 1-cos(theta) graph, where theta is the bend angle of the DNA and P(theta) > is the angular probability. From GROMACS what I obtained was as follows- > > # This file was created Thu Sep 3 07:02:19 2015 > # by the following command: > # g_polystat -f mdfinal_60ns.xtc -s mdfinal_60ns.tpr -p persist_18mm.xvg > # > # g_polystat is part of G R O M A C S: > # > # GRoups of Organic Molecules in ACtion for Science > # > @title "Persistence length" > @xaxis label "Time (ps)" > @yaxis label "bonds" > @TYPE xy > 0.000 0.4025 > 2.000 0.4472 > 4.000 0.4527 > 6.000 0.4958 > 8.000 0. > 10.000 0.5157 > 12.000 0.5164 > 14.000 0.5471 > 16.000 0.5090 > > Here, the time evolution of some bonds are given. Can anyone help resolving > the issue? > > Thanks in advance, > Soumadwip Ghosh > Research Fellow, > IITB > Mumbai > India > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] calculating total percentage of time from gibbs free energy landscape
can the following work? http://unix.stackexchange.com/questions/12068/how-to-measure-time-of-program-execution-and-store-that-inside-a-variable On Fri, Sep 11, 2015 at 7:57 AM, Nabawrote: > Is it possible to calculate total percentage of time invested to attain a > minima from Gibbs free energy landscape obtained by g_sham output, such as > from gibbs.xpm? Please guide me if there is any script available to do it. > > Nabajyoti Goswami > > Bioinformatics Infrastructure Facility > Department of Animal Biotechnology > College of Veterinary Science > Khanapara,Guwahati 781022 > Assam, India > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] reaction field and permittivity
thank you very much. On Thu, Sep 10, 2015 at 4:43 PM, Justin Lemkul <jalem...@vt.edu> wrote: > > > On 9/10/15 4:40 PM, Johnny Lu wrote: > >> Dear Users, >> >> I used mdp file at the following url for NVE vacuum simulation >> >> http://shourjya.thinkbiosolution.com/wp-content/uploads/2013/02/nvevaccmdp1.txt >> >> Does epsilon_rf affect the simulation? >> >> epsilon_rf is dielectric constant beyond the cut-off. >> >> > No. > > Since I set 0 for all the cut-off, the cut-off should be infinity. Does >> that means the epsilon_rf never get used ? >> >> > Yes. > > Also, epsilon_r = 1. So the simulation will always use the vacuum >> permittivity when calculating coulombic interactions? >> >> > > https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2004-March/009650.html > > -Justin > > -- > == > > Justin A. Lemkul, Ph.D. > Ruth L. Kirschstein NRSA Postdoctoral Fellow > > Department of Pharmaceutical Sciences > School of Pharmacy > Health Sciences Facility II, Room 629 > University of Maryland, Baltimore > 20 Penn St. > Baltimore, MD 21201 > > jalem...@outerbanks.umaryland.edu | (410) 706-7441 > http://mackerell.umaryland.edu/~jalemkul > > == > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] reaction field and permittivity
Dear Users, I used mdp file at the following url for NVE vacuum simulation http://shourjya.thinkbiosolution.com/wp-content/uploads/2013/02/nvevaccmdp1.txt Does epsilon_rf affect the simulation? epsilon_rf is dielectric constant beyond the cut-off. Since I set 0 for all the cut-off, the cut-off should be infinity. Does that means the epsilon_rf never get used ? Also, epsilon_r = 1. So the simulation will always use the vacuum permittivity when calculating coulombic interactions? Thank you for your help. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Vacuum versus Water Simulation
After checking the motion of the whole molecule, the vacuum simulation has a stronger periodic component than the simulation in water. so it is fine now. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Vacuum versus Water Simulation
Dear Users, Hi. Alanine peptide was simulated in water and in vacuum under NVE ensemble. The magnitude of harmonic components were similar in both simulations (as shown by Fourier transformation). Is this normal? I thought without the damping by water, the vacuum simulation would have a much stronger harmonic component of motion (which is not the case). >From rmsd, I think the peptide still moved in the vacuum simulation. Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] NVE Vacuum Fluctuation of Energy
Dear Users, I was trying to run NVE simulation of alanine peptide in vacuum with double precision gromacs 5.1. [plot of energy at http://postimg.org/image/6b6kksax7/] The total energy of the simulation still has fluctuation about 1kcal/mol. There should be no fluctuation of total energy in an ideal world. What are the possible source of this fluctuation? I'm testing the error contributed by the integrator by halving the time-step. How big is the error caused by integrator, error caused by h-bond constraint, and fluctuation caused by thermostat relative to each other? Previously I used the same mdp file, except with 1fs time step and with H-bond constraint, to simulate alanine peptide in water. The total energy of the whole system seemed conserved. I now wonder if that conservation is actually a cancellation of different numerical errors. When I run alanine peptide in vacuum, H-bond constraint made the energy drop quickly. I set constraint to none, and the energy drop was lower. The question I'm interested in is verification of a theory. It is affected by the shape and pattern of these errors. Without knowing the pattern of these errors, I hope the errors are small enough. Thank you again. The mdp file is below. the box size is large enough such that the distance between mirror image of the molecules is larger than the cut off for vdw and coulomb forces. title= Alanine ; Run parameters integrator= md; leap-frog integrator nsteps= 3; 300 ns dt= 0.0005; 0.5 fs ; Output control nstxout= 10; save coordinates every 1.0 ps nstvout= 10; save velocities every 1.0 ps nstfout= 10 nstenergy= 500; save energies every 1.0 ps nstlog= 500; update log file every 1.0 ps ; Bond parameters continuation= no; Restarting after NPT equilibration 1 constraint_algorithm= lincs; holonomic constraints constraints= none; all bonds (even heavy atom-H bonds) constrained lincs_iter= 2; accuracy of LINCS lincs_order= 4; also related to accuracy ; Neighborsearching cutoff-scheme = Verlet ns_type= grid; search neighboring grid cells nstlist= 20; 20 fs, largely irrelevant with Verlet scheme rcoulomb= 1.0; short-range electrostatic cutoff (in nm) rvdw= 1.0; short-range van der Waals cutoff (in nm) ; Electrostatics coulombtype= PME; Particle Mesh Ewald for long-range electrostatics pme_order= 4; cubic interpolation fourierspacing= 0.1; grid spacing for FFT tcoupl= no; no thermostat pcoupl= no; no barostat ; Periodic boundary conditions pbc= xyz; 3-D PBC ; Dispersion correction DispCorr= EnerPres; account for cut-off vdW scheme ; Velocity generation gen_vel= yes; Velocity generation is off verlet-buffer-drift = 0.0005 -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Split Trajectory file into parts
The file system seemed to have no quota, after checking with that command. The problem seems to be that the simulation I set up save too quickly for the file system. Splitting the trajectory into parts only alleviated but not solved the problem. in the end I ran the simulation at another place. On Mon, Aug 31, 2015 at 3:50 AM, Peter Kroon <p.c.kr...@rug.nl> wrote: > > > On 29/08/15 16:22, Justin Lemkul wrote: > > > > > > On 8/29/15 9:10 AM, Johnny Lu wrote: > >> Dear Users, > >> > >> Simulation writes to a Lustre file system (a distributed file system > >> made > >> of many hard drives). > >> About 100 Gb was written in 1 hrs. After a while, gromacs 5.1 says it > >> can't > >> write the trajectory file. > >> The file system still has lots of space. Not sure if that was because > >> one > >> of the many hard drives filled up. > Does your cluster implement filesystem quotas? Did you reach it? On our > cluster (which also uses Lustre) I use `lfs quota /home` to see my quota > and usage on the partition /home. > > Peter > >> > >> Is it possible to ask gromacs to automatically split the trajectory > >> files > >> into parts? > > > > No. > > > >> Or, I have to write a shell script to make gromacs restart the > >> simulation > >> every 15 minutes? > >> > > > > Yes. Or, heed what grompp tells you about how much data will be > > generated and simply construct a very trivial loop to execute mdrun > > for N steps, invoke convert-tpr, mdrun -cpi -noappend, etc. > > > > -Justin > > > > > > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] charge neutralization in vacuum simulations
was that for mass spectrometry? On Tue, Sep 1, 2015 at 1:30 PM, Vitaly V. Chabanwrote: > To get a neutral protein, protonate all residues... > > Another question is what's your simulation goal, since protonated and > deprotonated residues behave obviously in a different way. > > > > > On Tue, Sep 1, 2015 at 6:57 AM, tasneem kausar > wrote: > > Dear Gromacs users > > > > I am trying to neutralized the protein having two chains with four > negative > > charge. > > I ran the command line as : pdb2gmx -c prtn.pdb -p -o -glu -asp. > > I have chosen one protonated glu and one protonated asp for each protein > > chain. > > The net charge is now zero. > > Am I going through the right step for the neutralization? > > If there is any other way to neutralize protein, please suggest. > > > > Thanks in advance > > -- > > Gromacs Users mailing list > > > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > > > * For (un)subscribe requests visit > > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] OPLS/AA parameters for 2-propanol
Not sure if those are for 2-propanol as a liquid or interaction between 2-propanol and protein. from googling "2 propanol opls/aa" 1. Development and Testing of the OPLS All-Atom Force Field on Conformational Energetics and Properties of Organic Liquids The parameters are in the supporting info. Seems not exactly 2-propanol. But it has parameter for organic liquids. "OPLS-AA Non-Bonded Parameters for Hydrocarbons and Alcohols" http://pubs.acs.org/doi/abs/10.1021/ja9621760 2. A statistical model of hydrogen bond networks in liquid alcohols http://publications.lib.chalmers.se/records/fulltext/local_157930.pdf 3. Parameterization of OPLS–AA Force Field for the Conformational Analysis of Macrocyclic Polyketides https://labs.chem.ucsb.edu/bruice/thomas/tcb_pdf/522.pdf On Tue, Sep 1, 2015 at 9:41 PM, Ebert Maximilianwrote: > Dear list, > > I wanted to know if anybody has parameters for 2-propanol in the OPLS/AA > format. Before deriving my own I thought it would be best to ask first. I > saw some posts that people used 2-propanol in OPLS but couldn’t find any > reference in google scholar. > > Thank you very much, > > Max > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] OPLS/AA parameters for 2-propanol
that was by google. I haven't parametrized forcefields. did they just put the pieces in http://pubs.acs.org/doi/abs/10.1021/ja9621760 together and say it can work for 2-propanol? On Tue, Sep 1, 2015 at 11:34 PM, Johnny Lu <johnny.lu...@gmail.com> wrote: > Not sure if those are for 2-propanol as a liquid or interaction between > 2-propanol and protein. > from googling "2 propanol opls/aa" > > 1. Development and Testing of the OPLS All-Atom Force Field on > Conformational Energetics and Properties of Organic Liquids > The parameters are in the supporting info. > Seems not exactly 2-propanol. But it has parameter for organic > liquids. > "OPLS-AA Non-Bonded Parameters for Hydrocarbons and Alcohols" > http://pubs.acs.org/doi/abs/10.1021/ja9621760 > > 2. A statistical model of hydrogen bond networks in liquid alcohols > > http://publications.lib.chalmers.se/records/fulltext/local_157930.pdf > > 3. Parameterization of OPLS–AA Force Field for the Conformational Analysis > of Macrocyclic Polyketides > https://labs.chem.ucsb.edu/bruice/thomas/tcb_pdf/522.pdf > > On Tue, Sep 1, 2015 at 9:41 PM, Ebert Maximilian <m.eb...@umontreal.ca> > wrote: > >> Dear list, >> >> I wanted to know if anybody has parameters for 2-propanol in the OPLS/AA >> format. Before deriving my own I thought it would be best to ask first. I >> saw some posts that people used 2-propanol in OPLS but couldn’t find any >> reference in google scholar. >> >> Thank you very much, >> >> Max >> -- >> Gromacs Users mailing list >> >> * Please search the archive at >> http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before >> posting! >> >> * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists >> >> * For (un)subscribe requests visit >> https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or >> send a mail to gmx-users-requ...@gromacs.org. > > > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] extend a simulation just with xtc file
can extend simulation if the number of steps were reached. http://www.gromacs.org/Documentation/How-tos/Extending_Simulations That said, does extending the simulation avoid the problems that you found in the simulation? On Tue, Sep 1, 2015 at 11:54 PM, Johnny Lu <johnny.lu...@gmail.com> wrote: > http://www.gromacs.org/Documentation/How-tos/Doing_Restarts > > > > On Tue, Sep 1, 2015 at 11:53 PM, Johnny Lu <johnny.lu...@gmail.com> wrote: > >> the position in xtc is not accurate enough for restarting simulation. xtc >> has no velocity. >> >> restart need position, velocity, and variables for the thermostat and >> barostat. >> >> Do you have any cpt file? may be you can run a restart using cpt and tpr >> files. >> >> On Mon, Aug 31, 2015 at 10:21 PM, Adriana Garro <adrianagarr...@gmail.com >> > wrote: >> >>> :-( ok >>> Thanks, I will have to run this simulation again. >>> Bye >>> >>> Adriana >>> >>> *** >>> Dra. Adriana D. Garro >>> Química Medicinal >>> Facultad de Química, Bioquímica y Farmacia >>> Universidad Nacional de San Luis >>> IMASL-CONICET >>> San Luis, Argentina >>> >>> Tel..:+54 266 4424689 int 6153 >>> e-mail...: adga...@unsl.edu.ar >>> e-mail...: adrianagarr...@gmail.com >>> >>> >>> ** >>> >>> 2015-08-31 23:17 GMT-03:00 Justin Lemkul <jalem...@vt.edu>: >>> >>> > >>> > >>> > On 8/31/15 11:52 AM, Adriana Garro wrote: >>> > >>> >> Dear Gromacs users, >>> >> >>> >> My 100 ns simulation finish but in a wrong way, I knew it when I >>> tried to >>> >> use an analizing tool and the message was the next one >>> >> >>> >> Fatal error: >>> >> Magic Number Error in XTC file (read 0, should be 1995) >>> >> >>> >> It seems that this kind of error is related to the network file >>> system. >>> >> My first attempt was restart (I am using gromacs 4.5.5) >>> >> mdrun -s topol.tpr -cpi state.cpt >>> >> but of course it finished immediately then I realized that the number >>> of >>> >> steps was reached. >>> >> >>> >> I did a copy of the md.xtc file while it was running in order to see >>> how >>> >> things were going on, aproximately at 85 ns, so I would like to know >>> if it >>> >> is possible to extend my simulation using this 85ns xtc file. (without >>> >> having cpt file) >>> >> >>> >> >>> > The .xtc has nothing useful about the state of the simulation. A set >>> of >>> > coordinates is inadequate for properly continuing a simulation. >>> > >>> > -Justin >>> > >>> > -- >>> > == >>> > >>> > Justin A. Lemkul, Ph.D. >>> > Ruth L. Kirschstein NRSA Postdoctoral Fellow >>> > >>> > Department of Pharmaceutical Sciences >>> > School of Pharmacy >>> > Health Sciences Facility II, Room 629 >>> > University of Maryland, Baltimore >>> > 20 Penn St. >>> > Baltimore, MD 21201 >>> > >>> > jalem...@outerbanks.umaryland.edu | (410) 706-7441 >>> > http://mackerell.umaryland.edu/~jalemkul >>> > >>> > == >>> > -- >>> > Gromacs Users mailing list >>> > >>> > * Please search the archive at >>> > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before >>> > posting! >>> > >>> > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists >>> > >>> > * For (un)subscribe requests visit >>> > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or >>> > send a mail to gmx-users-requ...@gromacs.org. >>> > >>> -- >>> Gromacs Users mailing list >>> >>> * Please search the archive at >>> http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before >>> posting! >>> >>> * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists >>> >>> * For (un)subscribe requests visit >>> https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or >>> send a mail to gmx-users-requ...@gromacs.org. >>> >> >> > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Gromacs-5.1 XLC Seg. Fault.
what is the computer you are using? i tried to build gromacs 4.6.7 on IBM System p7 755. It was very tedious. I had to build cmake. I think I even tried to build gnu gcc compiler. The end result was that gromacs ran very slow. On Tue, Aug 25, 2015 at 4:08 PM, Carlos Aguniwrote: > Hello guys. > > I've compiled Gromacs-5.1 with XLC 13.1.2 + ESSL and FFTW (altivec enabled) > but > I'm getting seg. fault while trying to run it. > I'm testing it with .96 workload. Here's its input: > http://pastebin.com/Ezp95b2B > > Here's the error I'm getting: > > [ubuntu:19418] *** Process received signal *** > > [ubuntu:19418] Signal: Segmentation fault (11) > > [ubuntu:19418] Signal code: Address not mapped (1) > > [ubuntu:19418] Failing at address: 0x1beefdebd > > [ubuntu:19418] [ 0] [0x3fff99cc0478] > > [ubuntu:19418] [ 1] > /lib/powerpc64le-linux-gnu/libpthread.so.0(pthread_mutex_lock+0x20) > [0x3fff961fb6b0] > > [ubuntu:19418] [ 2] mdrun_mpi() [0x10266830] > > [ubuntu:19418] [ 3] mdrun_mpi(tMPI_Thread_mutex_lock+0x30) [0x1044f9f0] > > [ubuntu:19418] [ 4] mdrun_mpi(gmx_detect_hardware+0x44) [0x1035b974] > > [ubuntu:19418] [ 5] mdrun_mpi(mdrunner+0x2cc) [0x100d6bfc] > > [ubuntu:19418] [ 6] mdrun_mpi(_Z9gmx_mdruniPPc+0x14b0) [0x100e0540] > > [ubuntu:19418] [ 7] mdrun_mpi() [0x101271fc] > > [ubuntu:19418] [ 8] > mdrun_mpi(_ZN3gmx24CommandLineModuleManager3runEiPPc+0x2f4) [0x1011bae4] > > [ubuntu:19418] [ 9] > > mdrun_mpi(_ZN3gmx24CommandLineModuleManager21runAsMainSingleModuleEiPPcPNS_26CommandLineModuleInterfaceE+0x9c) > [0x1011bf4c] > > [ubuntu:19418] [10] > > mdrun_mpi(_ZN3gmx24CommandLineModuleManager14runAsMainCMainEiPPcPFiiS2_E+0x70) > [0x1011c0e0] > > [ubuntu:19418] [11] mdrun_mpi(main+0x24) [0x100d0374] > > [ubuntu:19418] [12] /lib/powerpc64le-linux-gnu/libc.so.6(+0x24e80) > [0x3fff96054e80] > > [ubuntu:19418] [13] > /lib/powerpc64le-linux-gnu/libc.so.6(__libc_start_main+0xc4) > [0x3fff96055074] > > [ubuntu:19418] *** End of error message *** > > -- > > And here's the md.log: > > http://pastebin.com/GCkY136Q > > > Is there anything I can do to help clarify this problem? > > Thanks in advance! > > Carlos. > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] extend a simulation just with xtc file
the position in xtc is not accurate enough for restarting simulation. xtc has no velocity. restart need position, velocity, and variables for the thermostat and barostat. Do you have any cpt file? may be you can run a restart using cpt and tpr files. On Mon, Aug 31, 2015 at 10:21 PM, Adriana Garrowrote: > :-( ok > Thanks, I will have to run this simulation again. > Bye > > Adriana > > *** > Dra. Adriana D. Garro > Química Medicinal > Facultad de Química, Bioquímica y Farmacia > Universidad Nacional de San Luis > IMASL-CONICET > San Luis, Argentina > > Tel..:+54 266 4424689 int 6153 > e-mail...: adga...@unsl.edu.ar > e-mail...: adrianagarr...@gmail.com > > > ** > > 2015-08-31 23:17 GMT-03:00 Justin Lemkul : > > > > > > > On 8/31/15 11:52 AM, Adriana Garro wrote: > > > >> Dear Gromacs users, > >> > >> My 100 ns simulation finish but in a wrong way, I knew it when I tried > to > >> use an analizing tool and the message was the next one > >> > >> Fatal error: > >> Magic Number Error in XTC file (read 0, should be 1995) > >> > >> It seems that this kind of error is related to the network file system. > >> My first attempt was restart (I am using gromacs 4.5.5) > >> mdrun -s topol.tpr -cpi state.cpt > >> but of course it finished immediately then I realized that the number of > >> steps was reached. > >> > >> I did a copy of the md.xtc file while it was running in order to see > how > >> things were going on, aproximately at 85 ns, so I would like to know if > it > >> is possible to extend my simulation using this 85ns xtc file. (without > >> having cpt file) > >> > >> > > The .xtc has nothing useful about the state of the simulation. A set of > > coordinates is inadequate for properly continuing a simulation. > > > > -Justin > > > > -- > > == > > > > Justin A. Lemkul, Ph.D. > > Ruth L. Kirschstein NRSA Postdoctoral Fellow > > > > Department of Pharmaceutical Sciences > > School of Pharmacy > > Health Sciences Facility II, Room 629 > > University of Maryland, Baltimore > > 20 Penn St. > > Baltimore, MD 21201 > > > > jalem...@outerbanks.umaryland.edu | (410) 706-7441 > > http://mackerell.umaryland.edu/~jalemkul > > > > == > > -- > > Gromacs Users mailing list > > > > * Please search the archive at > > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > > posting! > > > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > > > * For (un)subscribe requests visit > > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > > send a mail to gmx-users-requ...@gromacs.org. > > > -- > Gromacs Users mailing list > > * Please search the archive at > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before > posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] extend a simulation just with xtc file
http://www.gromacs.org/Documentation/How-tos/Doing_Restarts On Tue, Sep 1, 2015 at 11:53 PM, Johnny Lu <johnny.lu...@gmail.com> wrote: > the position in xtc is not accurate enough for restarting simulation. xtc > has no velocity. > > restart need position, velocity, and variables for the thermostat and > barostat. > > Do you have any cpt file? may be you can run a restart using cpt and tpr > files. > > On Mon, Aug 31, 2015 at 10:21 PM, Adriana Garro <adrianagarr...@gmail.com> > wrote: > >> :-( ok >> Thanks, I will have to run this simulation again. >> Bye >> >> Adriana >> >> *** >> Dra. Adriana D. Garro >> Química Medicinal >> Facultad de Química, Bioquímica y Farmacia >> Universidad Nacional de San Luis >> IMASL-CONICET >> San Luis, Argentina >> >> Tel..:+54 266 4424689 int 6153 >> e-mail...: adga...@unsl.edu.ar >> e-mail...: adrianagarr...@gmail.com >> >> >> ** >> >> 2015-08-31 23:17 GMT-03:00 Justin Lemkul <jalem...@vt.edu>: >> >> > >> > >> > On 8/31/15 11:52 AM, Adriana Garro wrote: >> > >> >> Dear Gromacs users, >> >> >> >> My 100 ns simulation finish but in a wrong way, I knew it when I tried >> to >> >> use an analizing tool and the message was the next one >> >> >> >> Fatal error: >> >> Magic Number Error in XTC file (read 0, should be 1995) >> >> >> >> It seems that this kind of error is related to the network file >> system. >> >> My first attempt was restart (I am using gromacs 4.5.5) >> >> mdrun -s topol.tpr -cpi state.cpt >> >> but of course it finished immediately then I realized that the number >> of >> >> steps was reached. >> >> >> >> I did a copy of the md.xtc file while it was running in order to see >> how >> >> things were going on, aproximately at 85 ns, so I would like to know >> if it >> >> is possible to extend my simulation using this 85ns xtc file. (without >> >> having cpt file) >> >> >> >> >> > The .xtc has nothing useful about the state of the simulation. A set of >> > coordinates is inadequate for properly continuing a simulation. >> > >> > -Justin >> > >> > -- >> > == >> > >> > Justin A. Lemkul, Ph.D. >> > Ruth L. Kirschstein NRSA Postdoctoral Fellow >> > >> > Department of Pharmaceutical Sciences >> > School of Pharmacy >> > Health Sciences Facility II, Room 629 >> > University of Maryland, Baltimore >> > 20 Penn St. >> > Baltimore, MD 21201 >> > >> > jalem...@outerbanks.umaryland.edu | (410) 706-7441 >> > http://mackerell.umaryland.edu/~jalemkul >> > >> > == >> > -- >> > Gromacs Users mailing list >> > >> > * Please search the archive at >> > http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before >> > posting! >> > >> > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists >> > >> > * For (un)subscribe requests visit >> > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or >> > send a mail to gmx-users-requ...@gromacs.org. >> > >> -- >> Gromacs Users mailing list >> >> * Please search the archive at >> http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before >> posting! >> >> * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists >> >> * For (un)subscribe requests visit >> https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or >> send a mail to gmx-users-requ...@gromacs.org. >> > > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] regarding box volume
I am new to simulation and haven't done any simulation for finding free energy. The following is my guess. How big are the molecules? If the box size is small then the concentration of the molecules is higher. May be the dissociation part is fine if: the hybrid can't see its mirror image (the intermolecular force between the hybrid and its mirror image is very weak). the partially dissociated hybrid can't see its mirror image. The rebinding part is fine if: Once the hybrid completely dissociated (AB -- A+B), both A and B have enough space such that A can't see B for a while. What do you want to know? If you want to know the free energy of the dissociation, may be the following tutorial can help: http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin/gmx-tutorials/free_energy/02_topology.html I guess that tutorial only require the hybrid can't see its mirror image. Might need thermodynamic cycle: http://openi.nlm.nih.gov/detailedresult.php?img=3203851_1741-7007-9-71-4req=4 On Sat, Aug 29, 2015 at 7:14 AM, soumadwip ghosh soumadwipgh...@gmail.com wrote: Ignore the previous mail. Hi, please excuse me if my question appears very silly to you. I have a hybrid of a Carbon nanotube and a polymer and I want to study the unwrapping dynamics of the polymer in presence of a polymer binding agent. I kept the hybrid inside a triclinic box and am doing simulations in presence of that binder for 100 ns. The size of the box is around 277 nm3. Is there a possibility that once the hybrid dissociates the polymer may not have enough volume to go apart from the CNT and hence affecting the correct dynamics picture? Should I perform such kind of simulations in a bigger box? I might be missing out something very fundamental. Your help would be appreciated. Sorry if I am asking for much. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] adding hydrogens to pdb file
Hi. reduce.exe seems not part of gromacs. http://kinemage.biochem.duke.edu/software/reduce.php On Thu, Aug 27, 2015 at 1:59 AM, elham tazikeh elham.tazi...@gmail.com wrote: Dear GMX users i want to *adding Hydrogens* to my lig.pdb (for making lig.itp file by ATB server) in cmd program in Windowds, but i dont know the way of that? i know the below command is used for that: reduce.exe -BUILD lig.pdb lig_h.pdb but i cant do it in cmd program i really appricite for any help elham -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Split Trajectory file into parts
Dear Users, Simulation writes to a Lustre file system (a distributed file system made of many hard drives). About 100 Gb was written in 1 hrs. After a while, gromacs 5.1 says it can't write the trajectory file. The file system still has lots of space. Not sure if that was because one of the many hard drives filled up. Is it possible to ask gromacs to automatically split the trajectory files into parts? Or, I have to write a shell script to make gromacs restart the simulation every 15 minutes? Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Restart -append
Dear Users, Simulation crashed. Gromacs 5.1 wrote last check point at about 4 min before the crash. Restart with mdrun -cpi (last check point file) -append Will the -append option get rid of the data for those 4 min between the last check point written and the crash? Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] How do I calculate the difference between two energy values?
Let x(t) be coulomb decoupling at time t. Let y(t) be VdW decoupling at time t. I guess the most safe way to get the answer is: calculate z(t) = x(t) + y(t) then, calculate standard deviation of z(t). If x(t) and y(t) are independent and both x(t) and y(t) are normally distributed, then I guess using the error propagation rule is fine. (https://en.wikipedia.org/wiki/Sum_of_normally_distributed_random_variables) On Tue, Aug 25, 2015 at 2:15 PM, Peter Stern peter.st...@weizmann.ac.il wrote: I believe that this is a statistics question and not a gromacs question :-). 51.4 +/- 1.33 kJ/mol Sent from my iPad On 25 באוג׳ 2015, at 14:44, minky son minky0...@gmail.com wrote: Dear GROMACS users, I have been studying free energy calculation in Justin tutorial. I performed VDW decoupling and coulomb decoupling simulations separately. I obtained the free energy values for each simulation using gmx bar. coulomb decoupling simulation = 60.88 +/- 0.23 kJ/mol VDW decoupling simulation= -9.48 +/- 1.31 kJ/mol So, I want to calculate the sum of the two energy values, specially the second term (51.4 +/- ???). Please give me any advice to solve this. Regards, -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Thread, Multiple gpu, and sharing node
Dear Users, Hi. The system has about 3k atoms, and I used a rhombic dodecahedron box. The node in the cluster has 2 sockets and 12 cores per socket. (24 sockets in total) It also has 4 gpu. Will I waste cpu time, if I run with all 24 cores and assign 1 gpu to 3 cores? Should I compile for mpi? Alternatively, I can run with just 12 cores and assign 1 gpu to every 3 cores. The remaining 12 cores and 2 gpu will be used by another user. Which way is a more efficient use of time per cpu core? Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] box size and neighbor list cut-off
Dear Users, Hi. Box vector length: 3.448, 3.448, 3.448 nm dodecahedron. (Box volume is 28.98 nm^3) Diameter of tripeptide: 1.248 nm Volume of tripeptide: 0.35503 nm^3 (from genbox output) Short range Neighbor list cut-off: 1.1 nm (set manually by rlist=1.1) Other short range cut off (VdW and electrostatic): 1.0 nm According to 5.2 manual (manual-5.2-dev.pdf), This means that the length of each box vector must exceed the length of the macromolecule in the direction of that edge plus two times the cut-off radius R_c Box vector length = Diameter of peptide + 2 x cut-off 3.448 = 1.248 + 2 x 1.1 Do I have to leave any leeway in the box size? (say, a box size of 3.5 nm) I will run a NPT simulation (Berendsen barostat). Then continue the simulation with a NVT simulation. And finally continue the NVT simulation with a NVE simulation. Last time when I ran a double precision NVE simulation, I set rlist=1.3 and used a 4.848^3 nm^3 dodecahedron box. The energy conservation was good. If I use a 1.1nm rlist, will I get an energy conservation that is nearly as good as the rlist = 1.3nm simulation? Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Respect waters in crystallographic pdb file?
I haven't tried that before. May be you can open the .gro files before and after genbox with a text editor. Then, check those water molecules? Those water molecules might have the same residue id. On Mon, Aug 17, 2015 at 1:42 PM, Jorge Fernandez de Cossio Diaz cos...@cim.sld.cu wrote: Hi all, I have a crystallographic PDB file which comes some waters molecules. I want to run an MD simulation which includes those water molecules. After generating the topology file (which includes the waters) and defining the box shape, I fill the box with solvent using genbox. At this point it becomes impossible to track down visually where the water molecules are. My question is if the file that genbox outputs still contains the crystallographic water molecules? Or are they replaced by the molecules added by genbox? Thanks in advance. Best, cossio --- [http://5.cim.co.cu/cim.gif] -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] box size and neighbor list cut-off
Sorry, I mean: If I use double precision gmx mdrun and constraint h-bonds, can I expect 1.135 rlist to give a drift in total energy as small as the one in the table? On Mon, Aug 17, 2015 at 5:07 PM, Johnny Lu johnny.lu...@gmail.com wrote: Thank you for the advices. I tried setting different varlet buffer drift in the 1st equilibration run (nvt) for 5 seconds. From the log file of mdrun, I get: rlistverlet-buffer-drift 1.090.05 1.1140.005 1.1350.0005 = 1.1730.05 1.2340.05 1.2840.05 Are these numbers real? The wiki says the constraints already causes 0.0001kj/mol/atom in single precision gmx mdrun. ( http://www.gromacs.org/Documentation/Cut-off_schemes#How_to_use_the_Verlet_scheme ) If I use double precision gmx mdrun and constraint h-bonds, can I expect 1.135 rlist to give a verlet-buffer-drift as small as the one in the table? Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] box size and neighbor list cut-off
Thank you for the advices. I tried setting different varlet buffer drift in the 1st equilibration run (nvt) for 5 seconds. From the log file of mdrun, I get: rlistverlet-buffer-drift 1.090.05 1.1140.005 1.1350.0005 = 1.1730.05 1.2340.05 1.2840.05 Are these numbers real? The wiki says the constraints already causes 0.0001kj/mol/atom in single precision gmx mdrun. ( http://www.gromacs.org/Documentation/Cut-off_schemes#How_to_use_the_Verlet_scheme ) If I use double precision gmx mdrun and constraint h-bonds, can I expect 1.135 rlist to give a verlet-buffer-drift as small as the one in the table? Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] refcoord-scaling without pressure coupling
Dear GMX users, If I set refcoord-scaling = com and also pcoupl = no, will that refcoord-scaling = com do anything (like introducing additional numerical error in a NVE simulation) ? Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] MD on protein-RNA complex
I guess: multi-chain means the system has multiple chains of polymer (such as peptide, or DNA/RNA). Some proteins have several peptide chains connected together. heterogeneous system: protein and RNA are different, and so protein + RNA is a heterogeneous system. Gromacs can simulate protein + RNA + water well, if the force field used can accurately describe the three components and the interaction between them. I don't know how accurate is the force-field that you use, in describing your system. In a perfect world, we have a force field that can accurately describe everything. Then, we can nearly simulate everything accurately. On Fri, Mar 6, 2015 at 4:16 AM, Brett brettliu...@163.com wrote: Dear Justin, What do you mean for Multi-chain and heterogeneous systems work out of the box? I am looking forward to getting your reply. Brett At 2015-03-04 10:50:10, Justin Lemkul jalem...@vt.edu wrote: On 3/3/15 9:34 PM, Brett wrote: Dear Justin, I mean is any difficulty or special for gromacs to recognize the RNA in the PDB file? Multi-chain and heterogeneous systems work out of the box. As with anything, the force field has to support everything and the nomenclature has to match the force field's expectations, but pdb2gmx will take care of everything. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 629 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Test if Trajectories are Independent
Hi. Is there a good way to test if a set of trajectories are independent from each other? I was thinking about a) show that the initial structures of the trajectories are sufficiently different. b) calculate rmsd between corresponding frames of two trajectories. If the trajectories are independent, the rmsd should be random and possibly have an autocorrelation with a fast decay to zero. I'm working with three 100 ns trajectories of alanine tripeptide. Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Element naming format in .pdb file
may be try both ways in a small file. feed it to pdb2gmx and then check the topol.top file to see if it uses the correct forcefield name? On Sat, Dec 20, 2014 at 12:12 AM, Rajan Kumar kumarrajan...@gmail.com wrote: Dear all, I am trying to study wetting of Graphene oxide. I have prepared a structure file using material studio, which I will simulate in GROMACS. My structure contain some epoxy and hydroxyl functional group in Graphene sheet. However, the structure file generated does not differentiate between carbon atoms with and without functional group in the Name column of .pdb file. Also there is no differentiation in naming format of oxygen atom in epoxy and hydroxyl group. Since, these atoms will have different atom type in atomtype.atp file of force filed.(I will be using OPLS-AA for simulation). Do I have to make edits in .pdb file for different atomtypes as well. Thanks Rajan Kumar Department of Chemical Engineering Indian Institute of Technology, Guwahati -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Ions drifting
If the Na or Cl ion don't strongly bind to the protein, as described by the force field, then they might not always bind to and stay with the protein in the simulation. If that is what you want, I guess you can artificially add a restraint to make the ion to stay closer to the protein ... I'm not sure about the consequence. On Thu, Dec 18, 2014 at 5:53 AM, Justin Lemkul jalem...@vt.edu wrote: On 12/17/14 11:47 PM, jani vinod wrote: Dear Johnny, I want to make the Na or Cl- ion always stay with the protein. I tried -pbc mol option ans selecting group as Protein_ion but it didn't work. This should be simple to do with trjconv -center -pbc mol -ur compact Choose Protein for centering and System for output. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 629 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] AMD GPUs
How about the open cl port of gromacs? http://streamcomputing.eu/blog/2014-11-01/ported-gromacs-cuda-opencl/ might have to check the list of bugs of 5.0 though. On Thu, Dec 18, 2014 at 5:16 AM, Szilárd Páll pall.szil...@gmail.com wrote: Hi, Please don't hijack other discussion threads! AMD GPUs will be supported in the next release, people did not use them before because they were not supported. Regarding performance, I only know the results of some early benchmarks in which the fastest card used was an R9 290 and ran about as fast as as GTX 780. Based on this expect that even the R9 290X will be a lot slower than a GTX 980, but it would be great if people on the list could try. Cheers, -- Szilárd On Thu, Dec 18, 2014 at 9:26 AM, Albert mailmd2...@gmail.com wrote: Hi Szilard: If I understand correctly, Gromacs also support AMD GPU? How fast is it? I never see people use it beforer THX Albert On 12/17/2014 10:09 PM, Szilárd Páll wrote: Hi Jason, Good point, separate PME ranks may very well be able to help in this case. I typically use half of the ranks for PME with AMD CPU-based machines (from 3-4 sockets and above). -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] compiling for xeon phi
Hi. How to compile double precision gromacs for xeon phi? (is that possible?) Do I need to use intel compiler, or gnu c/c++ is fine? Is the xeon phi code of gromacs 5.0.4 very different from the xeon phi code of gromacs 4.6.7? In the cmake command, do i have to change -DCMAKE_TOOLCHAIN_FILE=Platform/XeonPhi according to the platform that I am using? Thanks again. === Below is my attempt at building gromacs 4.6.7 for xeon phi. export CC=icc export CXX=icpc cmake .. -DCMAKE_TOOLCHAIN_FILE=Platform/XeonPhi give following error CMake Error at /mcms/x86_64/core/cmake/ 2.8.12.2/share/cmake-2.8/Modules/CMakeDetermineSystem.cmake:99 (message): Could not find toolchain file: Platform/XeonPhi Call Stack (most recent call first): CMakeLists.txt:47 (project) CMake Error: Error required internal CMake variable not set, cmake may be not be built correctly. Missing variable is: CMAKE_C_COMPILER_ENV_VAR CMake Error: Error required internal CMake variable not set, cmake may be not be built correctly. Missing variable is: CMAKE_C_COMPILER CMake Error: Could not find cmake module file: gromacs-4.6.7/build_phi/CMakeFiles/2.8.12.2/CMakeCCompiler.cmake CMake Error: CMAKE_C_COMPILER not set, after EnableLanguage -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] CG MD Simulation of DNA and PAMAM dendrimers
Hi. This mail list can not take attachment. So it might be better to just past the mdp file in the message. At which time step did the segmentation fault happen? On Wed, Dec 17, 2014 at 1:43 PM, Doa Hawamdeh hawamdeh@gmail.com wrote: Dear GROMACS users: I want to study the complexation between PAMAM dendrimer and DNA using coarse-graining molecular dynamics simualtions (MARTINI force field) utilizing GROMACS version 5.0.3. MD integrator is used with time step of 20 fs, but I could not run the simulation with this time step, I got *segmentation fault. *Sure before running long simulation I minimized the system. I attached the .mdp file that I use. Could you please help me? Waiting your response. Thank you. Doa -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Ions drifting
Hi. I guess the pbc option only make a previously non-periodic box become periodic. Do you want to: 1. Make the Na or Cl- ion always stay with the protein. Or 2. Make the protein looks like it stays at the center of the box. (but it can still rotate) I think the protein would look like it stays one piece as well. Or 3. Make the protein looks like it doesn't rotate. May be this post can help: https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2014-December/094369.html On Wed, Dec 17, 2014 at 10:57 PM, jani vinod genomej...@gmail.com wrote: Dear Justin and Tsjerk, Thanks for suggestion . It seems to be visualization problem . Since when I observed gro file generated at the end of simulation appear to be normal . I tried various option with pbc (whole followed by nojump) , pbc(mol -ur compact), pbc (whole , clust , nojump) but none of this seems to be working in my case. I followed the gromacs page where they mentioned how to deal pbc problem but that also didn't help. So is their any protocol for such system where we want to see interaction of solvent with solute. Thanks and regards Vinod On Wed, Dec 17, 2014 at 6:29 PM, Justin Lemkul jalem...@vt.edu wrote: On 12/16/14 11:41 PM, jani vinod wrote: Thanks following was the mdp file title = Protein in ions ; Run parameters integrator = md; nsteps = 5000 ; dt = 0.002 ; ; Output control nstxout = 5000 ; nstvout = 5000 ; nstenergy = 5000 ; nstlog = 5000 ; nstxtcout = 5000 ; ; Bond parameters continuation= yes ; constraint_algorithm= lincs ; constraints = all-bonds ; lincs_iter = 1 ; lincs_order = 4 ; ; Neighborsearching ns_type = grid ; nstlist = 10 ; rcoulomb= 1.0 ; rlist = 1.0 ; rvdw= 1.0 ; ; Electrostatics coulombtype = PME ; pme_order = 4 ; fourierspacing = 0.16 ; ; Temperature coupling is on tcoupl = Nose-Hoover tc-grps = Protein Non_Protein tau_t = 0.5 0.5 ; ref_t = 300 300 ; ; Pressure coupling is on pcoupl = Parrinello-Rahman ; pcoupltype = isotropic ; tau_p = 2.0 ; ref_p = 1.0 ; compressibility = 4.5e-5; ; Periodic boundary conditions pbc = xyz ; ; Dispersion correction DispCorr= EnerPres ; ; Velocity generation gen_vel = no; nstcomm = 1 comm-mode = Linear comm-grps = Protein Non_Protein It does not make sense to separate COM motion removal like this for a simple protein in water. As to whether or not this is related to the problem at hand, I can't necessarily say, but it is artificial. . So I processed the trajectory with trjconv whole option followed by nojump. After that the protein appear on one side and ions on other So this is all likely a visualization issue. Use trjconv to center the protein in the unit cell in conjunction with -pbc mol. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 629 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! *
Re: [gmx-users] 5.0.4 Compilation - SelectionUnitTests Failed
Hmm. Did you try gcc? From the mail list, I heard that if the gnu c/c++ compiler is new enough, it builds faster gromacs than intel c/c++ compiler and mkl. I'm not sure about 5.0.4 though, and I am using 4.6.7 right now. On Tue, Dec 16, 2014 at 10:09 AM, Mike Hanby mha...@uab.edu wrote: Howdy, I'm attempting to build Gromacs 5.0.4 using Intel compilers 13.1.1 for one of the users of our HPC fabric and it errors when running test 13 during the make check [--] Global test environment tear-down [==] 139 tests from 8 test cases ran. (462 ms total) [ PASSED ] 138 tests. [ FAILED ] 1 test, listed below: [ FAILED ] SelectionCollectionDataTest.HandlesCharge 1 FAILED TEST Total Test time (real) = 148.29 sec The following tests FAILED: 13 - SelectionUnitTests (Failed) Errors while running CTest make[3]: *** [CMakeFiles/run-ctest] Error 8 make[2]: *** [CMakeFiles/run-ctest.dir/all] Error 2 make[1]: *** [CMakeFiles/check.dir/rule] Error 2 make: *** [check] Error 2 I've attached the cmake, make and make check logs. Any suggestions on what I can do to debug / fix this issue, or is it benign and I can safely move on to installing? Thanks, Mike -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] 0 +- 0.5 bar ok?
Hi. Are these pressures acceptable for reviewers? (I haven't submit anything to journals before). What would be different from a simulation with a truly 1 bar average pressure? System 1: NVT simulation gives an 0.0 +- 0.5 bar average pressure over 600ns with 2 fs timestep. When I averaged the 2nd half of the simulation, it gives -0.3 +- 0.5 bar average pressure over 300 ns. The system has 9K water molecules, 3 Cl- ions, and 173 amino acid residues (2598 atoms). System 2: Another simulation that i did was an alanine dipeptide simulation with a 5.4 +- 0.2 bar pressure over 250 ns. The last 150 ns gives an average pressure of 5.6 +- 0.2 bar. The system has 8k water molecules and 32 peptide atoms. Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] trjconv during transfer of .trr
Alternatively, is there a way to quickly check how many ns or frames do a .trr file contain? On Sun, Dec 14, 2014 at 5:47 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. Before the queue manager of the cluster finishes transferring the .trr file to my homedirectory, if I start trjconv, and trjconv finishes running (which takes about half an hour) after the .trr file (6 GB) completes transferring to my home directory, will the converted .trr contains as many ns as the original .trr? I used trjconv to only get rid of the water in the .trr file. Or... part of the .trr file will get chop off when i convert with trjconv? Thank you for your help. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] trjconv during transfer of .trr
seems to be fine for slurm resource manager... so far. On Sun, Dec 14, 2014 at 5:50 PM, Johnny Lu johnny.lu...@gmail.com wrote: Alternatively, is there a way to quickly check how many ns or frames do a .trr file contain? On Sun, Dec 14, 2014 at 5:47 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. Before the queue manager of the cluster finishes transferring the .trr file to my homedirectory, if I start trjconv, and trjconv finishes running (which takes about half an hour) after the .trr file (6 GB) completes transferring to my home directory, will the converted .trr contains as many ns as the original .trr? I used trjconv to only get rid of the water in the .trr file. Or... part of the .trr file will get chop off when i convert with trjconv? Thank you for your help. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Stop protein diffusion in simulation box to make a movie
hi. can this help? http://manual.gromacs.org/programs/gmx-trjconv.html On Sat, Dec 13, 2014 at 6:04 AM, Hassan Aaryapour hassan.grom...@gmail.com wrote: Dear Gromacs Users, I made a trajectory movie using VMD and smoothing increased for getting the residues motion slower, but the protein is translate and diffuse in box, and causes very hard of seeing and analyzing how ligand structure changes during simulation. How can I stop the protein translation and following ligand motion easier? Thank you in advance Hassan -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Need to Sort Out
Hi. I'm quite new to molecular dynamics too. How did you make that itp? Does your system contain only one protein/DNA molecule? May be try this tutorial for a single protein? http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin/gmx-tutorials/lysozyme/ Check multiple journal papers when you decide how to simulate (even if you are just simulating a single small protein). Some systems might need different simulation steps. And, depending on the things that you want to look at, you might have to stage a different simulation. On Sat, Dec 13, 2014 at 1:46 PM, Devender Arora devar...@hotmail.com wrote: I am facing a problem in Gromacs while running grommp please do give the right direction I am new to Molecular dynamics. Fatal error: Syntax error - File topol_Protein_chain_A.itp, line 6966 Last line read: '[ molecules ]' Invalid order for directive molecules For more information and tips for troubleshooting, please check the GROMACS website at http://www.gromacs.org/Documentation/Errors : Thanks Regards Devender Arora Ph.D Scholar Department of Biotechnology GB Pant engineering College Pauri Garhwal, Uttarakhand Contact No. +919720045608, +91986896786 -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] trjconv precision lost from double to single conversion
Hi. I'm using gromacs 4.6.7 If the trr trajectory file is from double precision calculation, and I use single precision trjconv to make a single precision trr trajectory, how much precision will I lose in position and in force? 1, 0.1, 0.01, or 0.001 angstrom and Newton? Is the lost of precision acceptable? I noticed that single precision trr seems to take about half the hard disk space of double precision trr. Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] trjconv precision lost from double to single conversion
When I test the disk space that I would save by getting rid the water in the trajectory, I found that only make the trajectory 1/4 as large as the original. The trajectory has both position and force. Yet, the proteins only have about 1/10 the number of atoms of the whole system. Group 0 ( System) has 29859 elements Group 1 (Protein) has 2598 elements Should the trajectory file size reduced to 1/4 instead of 1/10? The command that I used was: echo -e 1\n1\n | $GMXHOME/trjconv_d -f $In_Traj -o $Out_Traj -s $In_ptr -pbc mol -ur compact -center -force Thanks again. On Fri, Dec 12, 2014 at 10:31 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I'm using gromacs 4.6.7 If the trr trajectory file is from double precision calculation, and I use single precision trjconv to make a single precision trr trajectory, how much precision will I lose in position and in force? 1, 0.1, 0.01, or 0.001 angstrom and Newton? Is the lost of precision acceptable? I noticed that single precision trr seems to take about half the hard disk space of double precision trr. Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] trjconv precision lost from double to single conversion
nevermind the 2nd question. it does reduce to about 1/10 size. On Fri, Dec 12, 2014 at 10:41 AM, Johnny Lu johnny.lu...@gmail.com wrote: When I test the disk space that I would save by getting rid the water in the trajectory, I found that only make the trajectory 1/4 as large as the original. The trajectory has both position and force. Yet, the proteins only have about 1/10 the number of atoms of the whole system. Group 0 ( System) has 29859 elements Group 1 (Protein) has 2598 elements Should the trajectory file size reduced to 1/4 instead of 1/10? The command that I used was: echo -e 1\n1\n | $GMXHOME/trjconv_d -f $In_Traj -o $Out_Traj -s $In_ptr -pbc mol -ur compact -center -force Thanks again. On Fri, Dec 12, 2014 at 10:31 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I'm using gromacs 4.6.7 If the trr trajectory file is from double precision calculation, and I use single precision trjconv to make a single precision trr trajectory, how much precision will I lose in position and in force? 1, 0.1, 0.01, or 0.001 angstrom and Newton? Is the lost of precision acceptable? I noticed that single precision trr seems to take about half the hard disk space of double precision trr. Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] pmetune and restarting
Hi. I notice that after I stop a simulation by specifying the number of hours that it runs with -maxh, and then restarting the simulation, at the beginning of each restart, the pme is tuned again. Will that cause any error if I periodically restart the simulation? How big is the error? Is it possible to save and reuse pme tune result by a mdrun option? Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] with 5.0: file INSTALL cannot find gmx
I'm not sure what happened, but so far when i install, i use full path instead of $(pwd) and it was fine for gromacs 4.6 and 5.0, 5.0.2. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] xeon-phi and double precision
Hi. Does xeon-phi make double precision gromacs faster? -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Question on installation
May be just let gromacs build its own fftw3 library, by using -DGMX_BUILD_OWN_FFTW=ON in the cmake command, is a better idea? On Mon, Dec 8, 2014 at 2:23 PM, Justin Lemkul jalem...@vt.edu wrote: On 12/8/14 12:38 PM, Igor Shchechkin wrote: Dear Gromacs users, I have obtained the error Cannot find fftw3f library installing 4.5.3 version of Gromacs. fftw 3.3.4 version has been preliminary installed, names of include and lib directories present in CPPFLAGS and LDFLAGS configuring Gromacs, both FFTW and Gromacs are configured in single precision. Mailing list is sought and the information found is irrelevant to my case. Could you, please, help me? You need to provide the actual command(s) you issued. If FFTW is installed, whatever you specified as a path during Gromacs installation was probably just wrong. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 629 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Dihedral angle calculation in Gromacs
what do you mean by tensor? On Fri, Nov 28, 2014 at 4:22 AM, Ankit Agrawal aka...@gmail.com wrote: Hi I have pdb file which has crystal structure of Cadherin-23 (2WHV) with 2 domains EC1 EC2. So I want to calculate angle between two domains (tensor) along with the principal axes. regards Ankit -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Precision of xtc-precision
Hi. What is the exact precision of xtc-precision = 1000 ? Does that mean the positions are accurate to 0.001 nm, or to 0.1% ? I searched gromacs 4.6.7 manual and gromacs.org for xtc-precision, but didn't find answer. Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Different box volumes from gmxdump and g_energy
Hi. I get two different volumes with g_energy and gmxdump. Which one is true? For now, I'm trying to get a NVT simulation with correct pressure, after a 300 ns NPT equilibration. The 400 ns NPT equilibration has the following statistics, according to g_energy of gromacs 4.6.7, and the equilibration seems to be sufficient. Last energy frame read 21438168 time 428763.375 Statistics over 214381681 steps [ 0. through 428763.3600 ps ], 5 data sets All statistics are over 17108015 points Energy Average Err.Est. RMSD Tot-Drift --- Total Energy-3073506.1nan -15.4944 (kJ/mol) Temperature 299.851 0.0018nan -0.00756116 (K) Pressure1.011275.7e-05nan 0.000126851 (bar) Volume 298.385 0.0043nan 0.00672558 (nm^3) Density 1015.42 0.015nan -0.0229017 (kg/m^3) gcq#328: I used to be blond and stupid, but now I dyed it black (Miss Li) The nan in RMSD is caused by that I did one restart of the simulation. Getting the correct volume is very important for me because the isothermal compressibility of water is 4.5e-5, and a small change in volume can lead to a relatively large change in pressure. gromacs5.0.1. g_energy_d time(ps) box-x box-y box-z volume - -- 125142.107.5006117.5006115.303739 298.383881 gromacs4.6.7. g_energy time(ps) volume - -- 125142.10 298.383881 gromacs4.6.7. gmxdump box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} from the box vectors, volume is |z dot (x cross y)| 7.50577 * 7.50577 * 5.30739 = 299.000218803 gromacs5.0.1. gmxdump_d box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} example command for running gmx_dump: gmxdump_d -s ../npt13c.tpr -f ../npt13c_step62571050.cpt gmxdump5.0.1d_step62571050 example command for running g_energy: g_energy_d -f ../npt13c.edr npt13c_volume_gromacs5.0.1_d.xvg since the timestep is 0.002 ps, the time(ps) corresponding to the check point file is: 62571050 * 0.002 = 125142.1 ps All the files (tpr, cpt, edr) are generated by mdrun of gromacs4.6.7 (mixed precision). It seems that it is ok to use the g_energy and gmxdump of gromacs 5.0.1 on these files. Size of the .edr file is 5 gb. Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Different box volumes from gmxdump and g_energy
g_energy seems more correct than gmxdump in box size. [= npt13c_step169777880. gmxdump =] box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} volume from box vector: 7.50577 * 7.50577 * 5.30739 = 299.000218803 [= npt13c. g_energy =] time(ps) volume - -- 339555.76 298.385254 [= commands for starting a NVT simulation, from the npt frame. =] ../../sofware/gromacs-4.6.7/bin/grompp -f nvt14d.mdp -c npt13c.tpr -t npt13c_step169777880.cpt -o nvt14d.tpr [= gmxdump_nvt14d_step62571050. gmxdump =] box (3x3): box[0]={ 7.50062e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50062e+00, 0.0e+00} box[2]={ 3.75032e+00, 3.75032e+00, 5.30375e+00} volume from box vector: 7.50062 * 7.50062 * 5.30375 = 298.385264414 (the same value in g_energy of npt13c) [= gmxdump_nvt14d_step6247910. gmxdump =] box (3x3): box[0]={ 7.50062e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50062e+00, 0.0e+00} box[2]={ 3.75032e+00, 3.75032e+00, 5.30375e+00} volume from box vector: 7.50062 * 7.50062 * 5.30375 = 298.385264414 On Wed, Dec 3, 2014 at 11:34 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I get two different volumes with g_energy and gmxdump. Which one is true? For now, I'm trying to get a NVT simulation with correct pressure, after a 300 ns NPT equilibration. The 400 ns NPT equilibration has the following statistics, according to g_energy of gromacs 4.6.7, and the equilibration seems to be sufficient. Last energy frame read 21438168 time 428763.375 Statistics over 214381681 steps [ 0. through 428763.3600 ps ], 5 data sets All statistics are over 17108015 points Energy Average Err.Est. RMSD Tot-Drift --- Total Energy-3073506.1nan -15.4944 (kJ/mol) Temperature 299.851 0.0018nan -0.00756116 (K) Pressure1.011275.7e-05nan 0.000126851 (bar) Volume 298.385 0.0043nan 0.00672558 (nm^3) Density 1015.42 0.015nan -0.0229017 (kg/m^3) gcq#328: I used to be blond and stupid, but now I dyed it black (Miss Li) The nan in RMSD is caused by that I did one restart of the simulation. Getting the correct volume is very important for me because the isothermal compressibility of water is 4.5e-5, and a small change in volume can lead to a relatively large change in pressure. gromacs5.0.1. g_energy_d time(ps) box-x box-y box-z volume - -- 125142.107.5006117.5006115.303739 298.383881 gromacs4.6.7. g_energy time(ps) volume - -- 125142.10 298.383881 gromacs4.6.7. gmxdump box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} from the box vectors, volume is |z dot (x cross y)| 7.50577 * 7.50577 * 5.30739 = 299.000218803 gromacs5.0.1. gmxdump_d box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} example command for running gmx_dump: gmxdump_d -s ../npt13c.tpr -f ../npt13c_step62571050.cpt gmxdump5.0.1d_step62571050 example command for running g_energy: g_energy_d -f ../npt13c.edr npt13c_volume_gromacs5.0.1_d.xvg since the timestep is 0.002 ps, the time(ps) corresponding to the check point file is: 62571050 * 0.002 = 125142.1 ps All the files (tpr, cpt, edr) are generated by mdrun of gromacs4.6.7 (mixed precision). It seems that it is ok to use the g_energy and gmxdump of gromacs 5.0.1 on these files. Size of the .edr file is 5 gb. Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Different box volumes from gmxdump and g_energy
yes. I get an xvg file from the edr file with g_energy. Then from the xvg file, i selected the observable (volume) corresponding to the timestep at which the .cpt file is written. Then I compared this value of volume, with the value of volume calculated from the box vectors in the .cpt file. On Wed, Dec 3, 2014 at 1:04 PM, Mark Abraham mark.j.abra...@gmail.com wrote: A .cpt file has one frame in it. An .edr file has values and statistics from many frames. Are you comparing things that are comparable? Mark On Wed, Dec 3, 2014 at 6:56 PM, Johnny Lu johnny.lu...@gmail.com wrote: g_energy seems more correct than gmxdump in box size. [= npt13c_step169777880. gmxdump =] box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} volume from box vector: 7.50577 * 7.50577 * 5.30739 = 299.000218803 [= npt13c. g_energy =] time(ps) volume - -- 339555.76 298.385254 [= commands for starting a NVT simulation, from the npt frame. =] ../../sofware/gromacs-4.6.7/bin/grompp -f nvt14d.mdp -c npt13c.tpr -t npt13c_step169777880.cpt -o nvt14d.tpr [= gmxdump_nvt14d_step62571050. gmxdump =] box (3x3): box[0]={ 7.50062e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50062e+00, 0.0e+00} box[2]={ 3.75032e+00, 3.75032e+00, 5.30375e+00} volume from box vector: 7.50062 * 7.50062 * 5.30375 = 298.385264414 (the same value in g_energy of npt13c) [= gmxdump_nvt14d_step6247910. gmxdump =] box (3x3): box[0]={ 7.50062e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50062e+00, 0.0e+00} box[2]={ 3.75032e+00, 3.75032e+00, 5.30375e+00} volume from box vector: 7.50062 * 7.50062 * 5.30375 = 298.385264414 On Wed, Dec 3, 2014 at 11:34 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I get two different volumes with g_energy and gmxdump. Which one is true? For now, I'm trying to get a NVT simulation with correct pressure, after a 300 ns NPT equilibration. The 400 ns NPT equilibration has the following statistics, according to g_energy of gromacs 4.6.7, and the equilibration seems to be sufficient. Last energy frame read 21438168 time 428763.375 Statistics over 214381681 steps [ 0. through 428763.3600 ps ], 5 data sets All statistics are over 17108015 points Energy Average Err.Est. RMSD Tot-Drift --- Total Energy-3073506.1nan -15.4944 (kJ/mol) Temperature 299.851 0.0018nan -0.00756116 (K) Pressure1.011275.7e-05nan 0.000126851 (bar) Volume 298.385 0.0043nan 0.00672558 (nm^3) Density 1015.42 0.015nan -0.0229017 (kg/m^3) gcq#328: I used to be blond and stupid, but now I dyed it black (Miss Li) The nan in RMSD is caused by that I did one restart of the simulation. Getting the correct volume is very important for me because the isothermal compressibility of water is 4.5e-5, and a small change in volume can lead to a relatively large change in pressure. gromacs5.0.1. g_energy_d time(ps) box-x box-y box-z volume - -- 125142.107.5006117.5006115.303739 298.383881 gromacs4.6.7. g_energy time(ps) volume - -- 125142.10 298.383881 gromacs4.6.7. gmxdump box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} from the box vectors, volume is |z dot (x cross y)| 7.50577 * 7.50577 * 5.30739 = 299.000218803 gromacs5.0.1. gmxdump_d box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} example command for running gmx_dump: gmxdump_d -s ../npt13c.tpr -f ../npt13c_step62571050.cpt gmxdump5.0.1d_step62571050 example command for running g_energy: g_energy_d -f ../npt13c.edr npt13c_volume_gromacs5.0.1_d.xvg since the timestep
Re: [gmx-users] Different box volumes from gmxdump and g_energy
The error in pressure of the nvt simulation (about -1.4 bar) is not explained by the error in pressure of the npt simulation. I wonder if the error in pressure of the NVT simulation is caused by that in the NPT simulation I used a berendsen barostat with a very low coupling time of 0.2 ps? I guess the worse case is that I get the NPT frames with volumes around (but not equal to) the average volume I get from g_energy, and then run NVT simulations starting from each of these NPT frames. And hopefully I get a NVT simulation with the correct pressure... I don't know what went wrong. I did convert the cpt file to pdb file, and then look at them in vmd to check for vacuum bubbles (and i don't see such bubbles in the water molecules). Below is my estimation of the errors: Somehow, the pressure of the nvt14d simulation is about -1.4 bar, instead of 1 bar. This error in pressure is not explained by the err in volume from the g_energy of npt13c, and the isothermal compressibility of water. [= g_energy of npt13c =] Statistics over 214381681 steps [ 0. through 428763.3600 ps ], 5 data sets All statistics are over 17108015 points Energy Average Err.Est. RMSD Tot-Drift --- Total Energy-3073506.1nan -15.4944 (kJ/mol) Temperature 299.851 0.0018nan -0.00756116 (K) Pressure1.011275.7e-05nan 0.000126851 (bar) Volume 298.385 0.0043nan 0.00672558 (nm^3) Density 1015.42 0.015nan -0.0229017 (kg/m^3) [= g_energy of nvt14d =] Last energy frame read 4715311 time 94306.219 Statistics over 22153111 steps [ 5. through 94306.2200 ps ], 1 data sets All statistics are over 2215312 points Energy Average Err.Est. RMSD Tot-Drift --- Pressure -1.40405 0.39146.2623.11836 (bar) gcq#98: Jesus Can't Save You, Though It's Nice to Think He Tried (Black Crowes) [= Approximate Maximal Error in Pressure (95% confidence, or two standard deviation) =] Assume the error estimation in averaged volume of npt13c is correct. 4.5e-5 = - (dV/dP)_T / V (Delta P)= - (Delta V)/ V / 4.5e-5 (Delta P)= - (0.0043*2)/ (298.385 - 0.0043*2) / 4.5e-5 = -0.6 bar Thus, there is 5% chance that the NPT simulation has a pressure as low as 1.0 - 0.6 = 0.4 bar. Yet, the actual pressure of the NVT simulation is -1.40405 +- 0.39, and 0.4 bar is not within two standard deviations of this value. On Wed, Dec 3, 2014 at 1:08 PM, Johnny Lu johnny.lu...@gmail.com wrote: yes. I get an xvg file from the edr file with g_energy. Then from the xvg file, i selected the observable (volume) corresponding to the timestep at which the .cpt file is written. Then I compared this value of volume, with the value of volume calculated from the box vectors in the .cpt file. On Wed, Dec 3, 2014 at 1:04 PM, Mark Abraham mark.j.abra...@gmail.com wrote: A .cpt file has one frame in it. An .edr file has values and statistics from many frames. Are you comparing things that are comparable? Mark On Wed, Dec 3, 2014 at 6:56 PM, Johnny Lu johnny.lu...@gmail.com wrote: g_energy seems more correct than gmxdump in box size. [= npt13c_step169777880. gmxdump =] box (3x3): box[0]={ 7.50577e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50577e+00, 0.0e+00} box[2]={ 3.75289e+00, 3.75289e+00, 5.30739e+00} volume from box vector: 7.50577 * 7.50577 * 5.30739 = 299.000218803 [= npt13c. g_energy =] time(ps) volume - -- 339555.76 298.385254 [= commands for starting a NVT simulation, from the npt frame. =] ../../sofware/gromacs-4.6.7/bin/grompp -f nvt14d.mdp -c npt13c.tpr -t npt13c_step169777880.cpt -o nvt14d.tpr [= gmxdump_nvt14d_step62571050. gmxdump =] box (3x3): box[0]={ 7.50062e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50062e+00, 0.0e+00} box[2]={ 3.75032e+00, 3.75032e+00, 5.30375e+00} volume from box vector: 7.50062 * 7.50062 * 5.30375 = 298.385264414 (the same value in g_energy of npt13c) [= gmxdump_nvt14d_step6247910. gmxdump =] box (3x3): box[0]={ 7.50062e+00, 0.0e+00, 0.0e+00} box[1]={ 0.0e+00, 7.50062e+00, 0.0e+00} box[2]={ 3.75032e+00, 3.75032e+00, 5.30375e+00} volume from box vector: 7.50062 * 7.50062 * 5.30375
[gmx-users] dump current rlist in cpt
Hi. is it possible to check current rlist, and vdw cut-off in a cpt file. I want to know if the big energy jump upon extending/continuing/restarting simulation with gromacs 4.6.7 is caused by the load balancing bug ( http://redmine.gromacs.org/issues/1603) Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] changing ewald_rtol
Thank you very much for the answer. On Tue, Nov 18, 2014 at 2:03 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Tue, Nov 18, 2014 at 7:38 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. from online manual: *ewald-rtol (1e-5)* The relative strength of the Ewald-shifted direct potential at *rcoulomb* is given by *ewald-rtol*. Decreasing this will give a more accurate direct sum, but then you need more wave vectors for the reciprocal sum. Is it ok to use ewald-rtol=1e-9 for Amber99SB-ILDN forcefield? That's not a question that has a useful single answer. 1) It wasn't parameterized with any Ewald method, so any subsquent use of that method is valid only upon empirical evidence. 2) Different observables in different systems have different dependencies on the quality of the electrostatics model, and this one parameter is only part of any story. 3) A tiny magnitude of forces at the cutoff matters little if they're being added to other forces at shorter distances - and if there's more than about 5 orders of magnitude difference, then the small ones get lost in the accumulation in floating-point representation 4) Making one part of the electrostatics approximation super accurate while ignoring the other doesn't do any good when you add them together, because the largest error dominates. 5) Some other error might be more dominant still (e.g. incomplete sampling, interior residues have the same charges as exterior residues, no polarizability) Will the sum in reciprocal space become very inaccurate? Yes, like the docs say, because ewald-rtol and rcoulomb are used to compute the Ewald splitting parameter beta, which is then used in reciprocal space also. Or this will just make the simulation run slower? By itself, it's just multiplication by a different scaling factor. Fixing the issues in reciprocal space (increasing number of grid points and/or spline interpolation order) will be expensive. Mark Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Equilibration from Non-shifted to Shifted Potential
I guess I get the idea now. F = -dV(x)/dx. So no time derivative is involved. So shifting the potential would not cause a suddenly impulse on the system. By the way, is Potential-shift the default vdw and coulomb-modifier (so that is used even if i didn't specify a modifier) for gromacs 4.6.7? I didn't see the default value when I searched for vdw-modifier (p.214) of gromacs manual 4.6.7, or when I look at the online manual. coulomb-modifier = Potential-shift rcoulomb-switch = 0 rcoulomb = 1 vdwtype = Cut-off vdw-modifier = Potential-shift On Fri, Nov 14, 2014 at 9:31 AM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, Try it and see ;-) mdrun -nsteps 10 -reprod -deffnm shifted mdrun -nsteps 10 -reprod -deffnm not-shifted gmx check -f shifted -f2 not-shifted gmx check -e shifted -e2 not-shifted Alternatively, given that the forces are not computed from the energies (e.g. by central difference or some such), what role does the potential energy play in the integration scheme? :-) Mark On Fri, Nov 14, 2014 at 3:19 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. If I change my potential from non-shifted to shift, will the sudden change of energy from non-shifted to shifted potential at step 0 completely mess up the equilibration? Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] restarting of shifted potential, 4.6.7 bug?
This seems to have nothing to do with shifted potentials or gpu. I run a tripeptide double precisiion NVE simulation on a machine with xeon cpu and without gpu. kill it, then continue it with the cpt file generated. That energy jump still exists. On Tue, Nov 11, 2014 at 1:39 PM, Johnny Lu johnny.lu...@gmail.com wrote: Going from non-shift to shifted potential changes the energy. So I was not surprised by the sudden jump of energy between step 0 and step 10 for the previous simulation (npt14). But the jump near step 0 for the current simulation (npt15) is not right. This is an equilibration run. I have just uploaded the files at http://redmine.gromacs.org/issues/1640 On Tue, Nov 11, 2014 at 10:54 AM, Mark Abraham mark.j.abra...@gmail.com wrote: On Tue, Nov 11, 2014 at 3:38 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I ran 30ns NPT with Potential-shift-Verlet on both potentials, continuing from a NPT without Potential-shift-Verlet. The energy dropped from -3e5 to -4e5, which is fine. After that, I continue the 30ns NPT with the same mdp file, except with a longer run time (300ns). The total energy was -4e5 at step 0, and then -3e5 at step 5000, and now at about 25 ns, it goes back to -3.5e5. Why the energy suddenly changed after step 0? IIRC, the restart ought to compute the same energy on the initial coordinates as it did at the end of the previous run, and even if there's no re-computation on the same coordinates, obviously it should not jump by 1e5 in a few steps (or one? can't tell from the resolution). I would think that might be a bug in filling a data structure for the output, but probably not one in the simulation itself. Please file an issue at http://redmine.gromacs.org, tarballing all the relevant files, and I'll try to look at it. The long-time behaviour of both simulations is pretty suspect though. Since you're prepared to be ultra-conservative with your non-bonded and SETTLE settings, I would explore using a 0.5fs time step (in normal and ultra-conservative mode). Berendsen is not a good barostat algorithm for production work, too... but I would not expect such a problem from its use. Perhaps more importantly, why are you turning off the long-range dispersion correction? Mark I used the same machine and same mixed precision gromacs 4.6.7 mdrun and grompp for both simulations. The plot of total energies for the two simulations: http://oi60.tinypic.com/ddmejd.jpg The two mdp files: http://oi58.tinypic.com/11980si.jpg The commands that I used for continuing the simulations: The previous simulation (npt14): ../../sofware/gromacs-4.6.7/bin/grompp -f npt14.mdp -c npt13.tpr -t npt13_step22620750.cpt -o npt14.tpr The current simulation (npt15): ../../sofware/gromacs-4.6.7/bin/grompp -f npt15.mdp -c npt14.tpr -t npt14_step3000.cpt -o npt15.tpr Thanks. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] restarting of shifted potential, 4.6.7 bug?
by the way, the machine has 4 Tesla K40m gpu, 32 xeon cpu with avx, and i ran: nohup ../../mdrun -deffnm npt15 -cpt 1 -cpnum On Tue, Nov 11, 2014 at 9:38 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I ran 30ns NPT with Potential-shift-Verlet on both potentials, continuing from a NPT without Potential-shift-Verlet. The energy dropped from -3e5 to -4e5, which is fine. After that, I continue the 30ns NPT with the same mdp file, except with a longer run time (300ns). The total energy was -4e5 at step 0, and then -3e5 at step 5000, and now at about 25 ns, it goes back to -3.5e5. Why the energy suddenly changed after step 0? I used the same machine and same mixed precision gromacs 4.6.7 mdrun and grompp for both simulations. The plot of total energies for the two simulations: http://oi60.tinypic.com/ddmejd.jpg The two mdp files: http://oi58.tinypic.com/11980si.jpg The commands that I used for continuing the simulations: The previous simulation (npt14): ../../sofware/gromacs-4.6.7/bin/grompp -f npt14.mdp -c npt13.tpr -t npt13_step22620750.cpt -o npt14.tpr The current simulation (npt15): ../../sofware/gromacs-4.6.7/bin/grompp -f npt15.mdp -c npt14.tpr -t npt14_step3000.cpt -o npt15.tpr Thanks. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] restarting of shifted potential, 4.6.7 bug?
The system has 30k water and a protein with ~170 amino acid. Here are the PME tuning: npt14: DD step 4 load imb.: force 58.1% step 10: timed with pme grid 80 80 80, coulomb cutoff 1.000: 37.1 M-cycles step 20: timed with pme grid 64 64 64, coulomb cutoff 1.173: 32.6 M-cycles step 30: timed with pme grid 56 56 56, coulomb cutoff 1.341: 34.5 M-cycles step 40: timed with pme grid 48 48 48, coulomb cutoff 1.564: 40.7 M-cycles step 50: timed with pme grid 72 72 72, coulomb cutoff 1.043: 33.9 M-cycles step 60: timed with pme grid 64 64 64, coulomb cutoff 1.173: 32.2 M-cycles step 70: timed with pme grid 60 60 60, coulomb cutoff 1.251: 32.8 M-cycles step 80: timed with pme grid 56 56 56, coulomb cutoff 1.341: 32.2 M-cycles step 90: timed with pme grid 52 52 52, coulomb cutoff 1.444: 32.2 M-cycles step 100: timed with pme grid 72 72 72, coulomb cutoff 1.043: 33.8 M-cycles step 110: timed with pme grid 64 64 64, coulomb cutoff 1.173: 40.3 M-cycles step 120: timed with pme grid 60 60 60, coulomb cutoff 1.251: 32.4 M-cycles step 130: timed with pme grid 56 56 56, coulomb cutoff 1.341: 33.0 M-cycles step 140: timed with pme grid 52 52 52, coulomb cutoff 1.444: 32.1 M-cycles optimal pme grid 52 52 52, coulomb cutoff 1.444 DD step 4999 load imb.: force 55.3% npt15: DD step 4 load imb.: force 41.2% step 10: timed with pme grid 80 80 80, coulomb cutoff 1.000: 36.6 M-cycles step 20: timed with pme grid 64 64 64, coulomb cutoff 1.181: 32.9 M-cycles step 30: timed with pme grid 56 56 56, coulomb cutoff 1.350: 33.6 M-cycles step 40: timed with pme grid 48 48 48, coulomb cutoff 1.575: 33.2 M-cycles step 50: timed with pme grid 44 44 44, coulomb cutoff 1.718: 35.8 M-cycles step 60: timed with pme grid 40 40 40, coulomb cutoff 1.890: 40.8 M-cycles step 70: timed with pme grid 80 80 80, coulomb cutoff 1.000: 36.5 M-cycles step 80: timed with pme grid 72 72 72, coulomb cutoff 1.050: 33.8 M-cycles step 90: timed with pme grid 64 64 64, coulomb cutoff 1.181: 32.0 M-cycles step 100: timed with pme grid 60 60 60, coulomb cutoff 1.260: 32.3 M-cycles step 110: timed with pme grid 56 56 56, coulomb cutoff 1.350: 31.6 M-cycles step 120: timed with pme grid 52 52 52, coulomb cutoff 1.454: 32.1 M-cycles step 130: timed with pme grid 48 48 48, coulomb cutoff 1.575: 32.3 M-cycles step 140: timed with pme grid 44 44 44, coulomb cutoff 1.718: 35.3 M-cycles step 150: timed with pme grid 42 42 42, coulomb cutoff 1.800: 37.7 M-cycles step 160: timed with pme grid 72 72 72, coulomb cutoff 1.050: 33.5 M-cycles step 170: timed with pme grid 64 64 64, coulomb cutoff 1.181: 32.0 M-cycles step 180: timed with pme grid 60 60 60, coulomb cutoff 1.260: 31.9 M-cycles step 190: timed with pme grid 56 56 56, coulomb cutoff 1.350: 31.4 M-cycles step 200: timed with pme grid 52 52 52, coulomb cutoff 1.454: 31.6 M-cycles step 210: timed with pme grid 48 48 48, coulomb cutoff 1.575: 32.0 M-cycles optimal pme grid 56 56 56, coulomb cutoff 1.350 DD step 4999 load imb.: force 41.0% On Tue, Nov 11, 2014 at 9:44 AM, Johnny Lu johnny.lu...@gmail.com wrote: by the way, the machine has 4 Tesla K40m gpu, 32 xeon cpu with avx, and i ran: nohup ../../mdrun -deffnm npt15 -cpt 1 -cpnum On Tue, Nov 11, 2014 at 9:38 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I ran 30ns NPT with Potential-shift-Verlet on both potentials, continuing from a NPT without Potential-shift-Verlet. The energy dropped from -3e5 to -4e5, which is fine. After that, I continue the 30ns NPT with the same mdp file, except with a longer run time (300ns). The total energy was -4e5 at step 0, and then -3e5 at step 5000, and now at about 25 ns, it goes back to -3.5e5. Why the energy suddenly changed after step 0? I used the same machine and same mixed precision gromacs 4.6.7 mdrun and grompp for both simulations. The plot of total energies for the two simulations: http://oi60.tinypic.com/ddmejd.jpg The two mdp files: http://oi58.tinypic.com/11980si.jpg The commands that I used for continuing the simulations: The previous simulation (npt14): ../../sofware/gromacs-4.6.7/bin/grompp -f npt14.mdp -c npt13.tpr -t npt13_step22620750.cpt -o npt14.tpr The current simulation (npt15): ../../sofware/gromacs-4.6.7/bin/grompp -f npt15.mdp -c npt14.tpr -t npt14_step3000.cpt -o npt15.tpr Thanks. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] restarting of shifted potential, 4.6.7 bug?
Going from non-shift to shifted potential changes the energy. So I was not surprised by the sudden jump of energy between step 0 and step 10 for the previous simulation (npt14). But the jump near step 0 for the current simulation (npt15) is not right. This is an equilibration run. I have just uploaded the files at http://redmine.gromacs.org/issues/1640 On Tue, Nov 11, 2014 at 10:54 AM, Mark Abraham mark.j.abra...@gmail.com wrote: On Tue, Nov 11, 2014 at 3:38 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. I ran 30ns NPT with Potential-shift-Verlet on both potentials, continuing from a NPT without Potential-shift-Verlet. The energy dropped from -3e5 to -4e5, which is fine. After that, I continue the 30ns NPT with the same mdp file, except with a longer run time (300ns). The total energy was -4e5 at step 0, and then -3e5 at step 5000, and now at about 25 ns, it goes back to -3.5e5. Why the energy suddenly changed after step 0? IIRC, the restart ought to compute the same energy on the initial coordinates as it did at the end of the previous run, and even if there's no re-computation on the same coordinates, obviously it should not jump by 1e5 in a few steps (or one? can't tell from the resolution). I would think that might be a bug in filling a data structure for the output, but probably not one in the simulation itself. Please file an issue at http://redmine.gromacs.org, tarballing all the relevant files, and I'll try to look at it. The long-time behaviour of both simulations is pretty suspect though. Since you're prepared to be ultra-conservative with your non-bonded and SETTLE settings, I would explore using a 0.5fs time step (in normal and ultra-conservative mode). Berendsen is not a good barostat algorithm for production work, too... but I would not expect such a problem from its use. Perhaps more importantly, why are you turning off the long-range dispersion correction? Mark I used the same machine and same mixed precision gromacs 4.6.7 mdrun and grompp for both simulations. The plot of total energies for the two simulations: http://oi60.tinypic.com/ddmejd.jpg The two mdp files: http://oi58.tinypic.com/11980si.jpg The commands that I used for continuing the simulations: The previous simulation (npt14): ../../sofware/gromacs-4.6.7/bin/grompp -f npt14.mdp -c npt13.tpr -t npt13_step22620750.cpt -o npt14.tpr The current simulation (npt15): ../../sofware/gromacs-4.6.7/bin/grompp -f npt15.mdp -c npt14.tpr -t npt14_step3000.cpt -o npt15.tpr Thanks. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Avg. Volume in NPT by Small Coupling Time
Hi. How to get an accurate average volume for a system, such that the pressure will be at 1 bar in a subsequent NVT run using this average volume? Is it ok to use Berendsen barostat with a very small time constant (0.2 ps) ? (At first I picked 0.1ps, gromacs 4.6.7 told me to use at least 0.2 ps). I was hoping that a smaller time constant would allow the simulation to sample the volume more frequently and Berendsen barostat would help the system to converge to the correct average volume faster. What are the possible draw backs? So far (2 ns), I see that the pressure fluctuation is smaller than a PR barostat. It seems to be fine to use Berendsen barostat for this purpose ( [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2011-February/058453.html] ) Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Pressure Question
I see. I'm using the V-rescaling thermostat in all simulations that I ran. I don't think I will use NPT for production run. I'm trying to get NVE production run in the end. If I use NVT production run, I will try to account for the effect of the thermostat (I'm not sure I can do that very well). On Thu, Nov 6, 2014 at 10:47 AM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, Note that using the Berendsen thermostat in Gromacs adds defects for no gain, compared with the Bussi v-rescale thermostat. The latter *is* Berendsen, plus a stochastic term that produces the right energy and velocity distributions (unlike Berendsen). I'd give serious consideration to rejecting a paper that used Gromacs and the Berendsen thermostat, particularly if they did not discuss why the known defects of Berendsen were acceptable for their work. Mark On Thu, Nov 6, 2014 at 4:18 PM, Johnny Lu johnny.lu...@gmail.com wrote: That post in the amber mailing list was quite interesting. May be using a weak berendsen thermostat in NVT is fine for them. Thanks for sharing that. On Thu, Nov 6, 2014 at 6:39 AM, Johnny Lu johnny.lu...@gmail.com wrote: I was not offended by the suggestion. With a sufficiently large number of water molecules, the protein would behave in the same way, under all three ensembles. Barostat and thermostat are artificial in some way. At least, even the diffusion coefficient is different in a force field paper that used both NVE and NVT. Langevin thermostat destroys some momentum transfer. This is my first paper, and I don't know if the reviewer will be fine if I report that my simulation has an average pressure of 11 bar with error 0.5 bar. On Thu, Nov 6, 2014 at 5:34 AM, Téletchéa Stéphane stephane.teletc...@univ-nantes.fr wrote: Le 06/11/2014 06:16, Antonio Baptista a écrit : In particular, the virial-based instantaneous pressure (call it P') computed in simulations has its ensemble average equal to the thermodynamic pressure P (check any good book on molecular simulation). But, as others already pointed out, this P' is well-known to show extremelly large fluctuations, meaning that its average computed from the simulation has usually a very large statistical spread. In other words, although the ensemble average of P' is strictly equal to P, its simulation average is a random variable that often shows large deviations from P (especially for short simulations). To get an idea of what is an acceptable error for the average of P', you may look at its distribution histogram in the NPT simulation. Dear Antonio, Sorry if my message sound aggressive when I talked about totally irrevelevant, I will clarify my thoughts. From a theoretical point of view, you are right, each ensemble is accessible. From a biological point of view, though, the concept of fixing the volume is less reasonable: we live at constant pressure and temperature, and also at tighly controlled pH, and salt concentrations. The volume varies though, as you feel it when the weather is getting hot or cold. My point was exactly what your are telling in a more formal way than me: this P' is well-known to show extremely large fluctuations Well, digging a bit more on my feeling, I also found opposite arguments on the AMBER mailing list, like here: http://archive.ambermd.org/201103/0431.html So I'll got back again on my research and adjust my mind on the actual bleeding edge simulations taking into account all the recent code and force fields progresses. Best, Stéphane -- Team Protein Design In Silico UFIP, UMR 6286 CNRS, UFR Sciences et Techniques, 2, rue de la Houssinière, Bât. 25, 44322 Nantes cedex 03, France Tél : +33 251 125 636 Fax : +33 251 125 632 http://www.ufip.univ-nantes.fr/ - http://www.steletch.org -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un
Re: [gmx-users] Avg. Volume in NPT by Small Coupling Time
Assume sampling is sufficient in all stages of simulations. Will the berendsen barostat with this coupling constant give both the correct average volume and correct average pressure? (despite the distribution is not canonical) Will that average pressure change when I switch to NVT ensemble? Can I switch to NVT directly (without doing a NPT with PR barostat) for a while, and then finally go to NVE production run? (a nature communication paper did that, but didn't report the barostat coupling constant they used in the NPT simulation.) On Thu, Nov 6, 2014 at 10:51 AM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, I think that's fine for rapidly forcing the volume to be close to the right equilibrium value, with low fluctuations. Then switch to gentler NPT (or constant-volume) for making a proper observation of the pressure. Mark On Thu, Nov 6, 2014 at 4:44 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. How to get an accurate average volume for a system, such that the pressure will be at 1 bar in a subsequent NVT run using this average volume? Is it ok to use Berendsen barostat with a very small time constant (0.2 ps) ? (At first I picked 0.1ps, gromacs 4.6.7 told me to use at least 0.2 ps). I was hoping that a smaller time constant would allow the simulation to sample the volume more frequently and Berendsen barostat would help the system to converge to the correct average volume faster. What are the possible draw backs? So far (2 ns), I see that the pressure fluctuation is smaller than a PR barostat. It seems to be fine to use Berendsen barostat for this purpose ( [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2011-February/058453.html ] ) Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Pressure Question
If the problem of using a 11 bar simulation is as big as the problem of drawing conclusion from a single simulation, I guess I have to get a pressure closer to 1 bar. Thanks. On Thu, Nov 6, 2014 at 10:55 AM, Johnny Lu johnny.lu...@gmail.com wrote: I see. I'm using the V-rescaling thermostat in all simulations that I ran. I don't think I will use NPT for production run. I'm trying to get NVE production run in the end. If I use NVT production run, I will try to account for the effect of the thermostat (I'm not sure I can do that very well). On Thu, Nov 6, 2014 at 10:47 AM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, Note that using the Berendsen thermostat in Gromacs adds defects for no gain, compared with the Bussi v-rescale thermostat. The latter *is* Berendsen, plus a stochastic term that produces the right energy and velocity distributions (unlike Berendsen). I'd give serious consideration to rejecting a paper that used Gromacs and the Berendsen thermostat, particularly if they did not discuss why the known defects of Berendsen were acceptable for their work. Mark On Thu, Nov 6, 2014 at 4:18 PM, Johnny Lu johnny.lu...@gmail.com wrote: That post in the amber mailing list was quite interesting. May be using a weak berendsen thermostat in NVT is fine for them. Thanks for sharing that. On Thu, Nov 6, 2014 at 6:39 AM, Johnny Lu johnny.lu...@gmail.com wrote: I was not offended by the suggestion. With a sufficiently large number of water molecules, the protein would behave in the same way, under all three ensembles. Barostat and thermostat are artificial in some way. At least, even the diffusion coefficient is different in a force field paper that used both NVE and NVT. Langevin thermostat destroys some momentum transfer. This is my first paper, and I don't know if the reviewer will be fine if I report that my simulation has an average pressure of 11 bar with error 0.5 bar. On Thu, Nov 6, 2014 at 5:34 AM, Téletchéa Stéphane stephane.teletc...@univ-nantes.fr wrote: Le 06/11/2014 06:16, Antonio Baptista a écrit : In particular, the virial-based instantaneous pressure (call it P') computed in simulations has its ensemble average equal to the thermodynamic pressure P (check any good book on molecular simulation). But, as others already pointed out, this P' is well-known to show extremelly large fluctuations, meaning that its average computed from the simulation has usually a very large statistical spread. In other words, although the ensemble average of P' is strictly equal to P, its simulation average is a random variable that often shows large deviations from P (especially for short simulations). To get an idea of what is an acceptable error for the average of P', you may look at its distribution histogram in the NPT simulation. Dear Antonio, Sorry if my message sound aggressive when I talked about totally irrevelevant, I will clarify my thoughts. From a theoretical point of view, you are right, each ensemble is accessible. From a biological point of view, though, the concept of fixing the volume is less reasonable: we live at constant pressure and temperature, and also at tighly controlled pH, and salt concentrations. The volume varies though, as you feel it when the weather is getting hot or cold. My point was exactly what your are telling in a more formal way than me: this P' is well-known to show extremely large fluctuations Well, digging a bit more on my feeling, I also found opposite arguments on the AMBER mailing list, like here: http://archive.ambermd.org/201103/0431.html So I'll got back again on my research and adjust my mind on the actual bleeding edge simulations taking into account all the recent code and force fields progresses. Best, Stéphane -- Team Protein Design In Silico UFIP, UMR 6286 CNRS, UFR Sciences et Techniques, 2, rue de la Houssinière, Bât. 25, 44322 Nantes cedex 03, France Tél : +33 251 125 636 Fax : +33 251 125 632 http://www.ufip.univ-nantes.fr/ - http://www.steletch.org -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail
Re: [gmx-users] Version problem
can look for all files with name mdrun by $ find / -name mdrun * mdrun_search and then $ cat mdrun_search On Thu, Nov 6, 2014 at 7:25 AM, Erik Marklund erik.markl...@chem.ox.ac.uk wrote: Hi, 'which mdrun' only tells you the location of the mdrun you're currently using and is no good here. How did you install 5.0.2? The CMake files should tell you where installation directory is. Kind regards, Erik On 6 Nov 2014, at 11:43, sa...@physics.iisc.ernet.in wrote: tried which mdrun showing the path /usr/bin/mdrun, which v4.6.5, however I have downloaded v5.0.2.tar.gz and used for installation. try to find mdrun program by typing this command on terminal: which mdrun will show path of mdrun program where it located. On Nov 6, 2014 4:01 PM, sa...@physics.iisc.ernet.in wrote: Dear Dr. Carsten Kutzner, I am unable to find the gmx5/bin/GMXRC in my machine, used 'locate' and 'find' to search the location. However I have source the following: source /usr/share/gromacs/shell-specific/GMXRC.bashrc Without this also mdrun is running. I am definitely missing something. Kindly help. With best regards, Satya On 06 Nov 2014, at 07:15, sa...@physics.iisc.ernet.in wrote: Dear all, I am new to GROMACS, just finish installation of v5.0.2, started reading online manual, as instructed executed the command: mdrun -version and the printout pasted below. It is printing GROMACS version 4.6.5, however I have installed version 5.0.2. What is the problem? Find the directory to where you have installed your GROMACS 5.0 executables and then do source /path/to/gmx5/bin/GMXRC which mdrun should now give you the 5.0 mdrun Carsten Regards, Satyabrata Das == Program: mdrun Gromacs version:VERSION 4.6.5 Precision: single Memory model: 64 bit MPI library:thread_mpi OpenMP support: enabled GPU support:disabled invsqrt routine:gmx_software_invsqrt(x) CPU acceleration: SSE4.1 FFT library:fftw-3.3.3-sse2-avx Large file support: enabled RDTSCP usage: enabled Built on: Sun Dec 15 04:01:11 UTC 2013 Built by: buildd@panlong [CMAKE] Build OS/arch: Linux 3.2.0-37-generic x86_64 Build CPU vendor: GenuineIntel Build CPU brand:Intel(R) Xeon(R) CPU E5620 @ 2.40GHz Build CPU family: 6 Model: 44 Stepping: 2 Build CPU features: aes apic clfsh cmov cx8 cx16 htt lahf_lm mmx msr nonstop_tsc pcid pclmuldq pdcm pdpe1gb popcnt pse rdtscp sse2 sse3 sse4.1 sse4.2 ssse3 C compiler: /usr/bin/x86_64-linux-gnu-gcc GNU gcc-4.8.real (Ubuntu/Linaro 4.8.2-10ubuntu1) 4.8.2 C compiler flags: -msse4.1-Wextra -Wno-missing-field-initializers -Wno-sign-compare -Wall -Wno-unused -Wunused-value -Wno-unused-parameter -Wno-array-bounds -Wno-maybe-uninitialized -Wno-strict-overflow -fomit-frame-pointer -funroll-all-loops -fexcess-precision=fast -O3 -DNDEBUG satyabrata@satyabrata-desktop:~$ -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Dr. Carsten Kutzner Max Planck Institute for Biophysical Chemistry Theoretical and Computational Biophysics Am Fassberg 11, 37077 Goettingen, Germany Tel. +49-551-2012313, Fax: +49-551-2012302 http://www.mpibpc.mpg.de/grubmueller/kutzner http://www.mpibpc.mpg.de/grubmueller/sppexa -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list *
Re: [gmx-users] Version problem
I typed an extra space that shouldn't be there. $ find / -name mdrun* mdrun_search On Thu, Nov 6, 2014 at 5:03 PM, Johnny Lu johnny.lu...@gmail.com wrote: can look for all files with name mdrun by $ find / -name mdrun * mdrun_search and then $ cat mdrun_search On Thu, Nov 6, 2014 at 7:25 AM, Erik Marklund erik.markl...@chem.ox.ac.uk wrote: Hi, 'which mdrun' only tells you the location of the mdrun you're currently using and is no good here. How did you install 5.0.2? The CMake files should tell you where installation directory is. Kind regards, Erik On 6 Nov 2014, at 11:43, sa...@physics.iisc.ernet.in wrote: tried which mdrun showing the path /usr/bin/mdrun, which v4.6.5, however I have downloaded v5.0.2.tar.gz and used for installation. try to find mdrun program by typing this command on terminal: which mdrun will show path of mdrun program where it located. On Nov 6, 2014 4:01 PM, sa...@physics.iisc.ernet.in wrote: Dear Dr. Carsten Kutzner, I am unable to find the gmx5/bin/GMXRC in my machine, used 'locate' and 'find' to search the location. However I have source the following: source /usr/share/gromacs/shell-specific/GMXRC.bashrc Without this also mdrun is running. I am definitely missing something. Kindly help. With best regards, Satya On 06 Nov 2014, at 07:15, sa...@physics.iisc.ernet.in wrote: Dear all, I am new to GROMACS, just finish installation of v5.0.2, started reading online manual, as instructed executed the command: mdrun -version and the printout pasted below. It is printing GROMACS version 4.6.5, however I have installed version 5.0.2. What is the problem? Find the directory to where you have installed your GROMACS 5.0 executables and then do source /path/to/gmx5/bin/GMXRC which mdrun should now give you the 5.0 mdrun Carsten Regards, Satyabrata Das == Program: mdrun Gromacs version:VERSION 4.6.5 Precision: single Memory model: 64 bit MPI library:thread_mpi OpenMP support: enabled GPU support:disabled invsqrt routine:gmx_software_invsqrt(x) CPU acceleration: SSE4.1 FFT library:fftw-3.3.3-sse2-avx Large file support: enabled RDTSCP usage: enabled Built on: Sun Dec 15 04:01:11 UTC 2013 Built by: buildd@panlong [CMAKE] Build OS/arch: Linux 3.2.0-37-generic x86_64 Build CPU vendor: GenuineIntel Build CPU brand:Intel(R) Xeon(R) CPU E5620 @ 2.40GHz Build CPU family: 6 Model: 44 Stepping: 2 Build CPU features: aes apic clfsh cmov cx8 cx16 htt lahf_lm mmx msr nonstop_tsc pcid pclmuldq pdcm pdpe1gb popcnt pse rdtscp sse2 sse3 sse4.1 sse4.2 ssse3 C compiler: /usr/bin/x86_64-linux-gnu-gcc GNU gcc-4.8.real (Ubuntu/Linaro 4.8.2-10ubuntu1) 4.8.2 C compiler flags: -msse4.1-Wextra -Wno-missing-field-initializers -Wno-sign-compare -Wall -Wno-unused -Wunused-value -Wno-unused-parameter -Wno-array-bounds -Wno-maybe-uninitialized -Wno-strict-overflow -fomit-frame-pointer -funroll-all-loops -fexcess-precision=fast -O3 -DNDEBUG satyabrata@satyabrata-desktop:~$ -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Dr. Carsten Kutzner Max Planck Institute for Biophysical Chemistry Theoretical and Computational Biophysics Am Fassberg 11, 37077 Goettingen, Germany Tel. +49-551-2012313, Fax: +49-551-2012302 http://www.mpibpc.mpg.de/grubmueller/kutzner http://www.mpibpc.mpg.de/grubmueller/sppexa -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests
[gmx-users] speed of 5.0.2 v.s 4.6
Hi. Do the two version of gromacs with mixed precision have similar speed? Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] speed of 5.0.2 v.s 4.6
Thanks. I guess I will keep version 4.6.7 for now. On Wed, Nov 5, 2014 at 11:40 AM, Mark Abraham mark.j.abra...@gmail.com wrote: Yes, in general. Mark On Wed, Nov 5, 2014 at 5:11 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. Do the two version of gromacs with mixed precision have similar speed? Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Pressure Question
The statistics was calculated for 80 ns of NVT simulation, after a 80 ns NPT simulation. In papers, I saw people talked about using the average volume of a previous NPT simulation to choose the frame with the correct volume. And then, run NVT starting from the NPT frame. But they don't talk about the pressure that they get in the NVT simulation (even in a force field paper). I just want to know if the reviewer will be ok with my paper, if I mention the pressure that I get in the NVT simulation. On Wed, Nov 5, 2014 at 12:16 PM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, That's hard to say. You'd need to do multiple converged simulations at each set of conditions to know. First, make sure you've made a significant observation of the pressure. Mark On Tue, Nov 4, 2014 at 6:00 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. If my NVT simulation of a protein in 30k molecules of water has a pressure of 11 bar (error 0.5 bar from g_energy), will the dynamics (not distribution of conformations) change enough that the mechanism inferred from this simulation be significantly more unreliable than the mechanism inferred from a 1 bar simulation? (Will the reviewers cut my paper into ribbons?) Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Pressure Question
the protein has about 170 amino acid. On Wed, Nov 5, 2014 at 1:13 PM, Johnny Lu johnny.lu...@gmail.com wrote: The statistics was calculated for 80 ns of NVT simulation, after a 80 ns NPT simulation. In papers, I saw people talked about using the average volume of a previous NPT simulation to choose the frame with the correct volume. And then, run NVT starting from the NPT frame. But they don't talk about the pressure that they get in the NVT simulation (even in a force field paper). I just want to know if the reviewer will be ok with my paper, if I mention the pressure that I get in the NVT simulation. On Wed, Nov 5, 2014 at 12:16 PM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, That's hard to say. You'd need to do multiple converged simulations at each set of conditions to know. First, make sure you've made a significant observation of the pressure. Mark On Tue, Nov 4, 2014 at 6:00 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. If my NVT simulation of a protein in 30k molecules of water has a pressure of 11 bar (error 0.5 bar from g_energy), will the dynamics (not distribution of conformations) change enough that the mechanism inferred from this simulation be significantly more unreliable than the mechanism inferred from a 1 bar simulation? (Will the reviewers cut my paper into ribbons?) Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Pressure Question
Well... I finally have to accept that I really need NVE. Some forum posts suggested to run NPT, then NVT, and finally NVE. For ideal gas law, if we fix the number of molecules and the temperature, then fixing the volume at different value means changing the pressure. So, I guess pressure is still meaningful, if I have to decide the correct volume to run the NVT simulation. For a large number of ideal gas molecules, averages of all thermodynamic variables should be defined, regardless of which three of them is fixed or which ensemble do I choose to represent the state. For a small number of molecules, the distribution of the thermodynamic variables should still have a definition (so, the average and the distribution of pressure is still meaningful). For a protein simulation, it still has a partition function, and equation of state. I mainly want to know how much error in pressure (deviation from 1 bar) is acceptable. On Wed, Nov 5, 2014 at 2:35 PM, Téletchéa Stéphane stephane.teletc...@univ-nantes.fr wrote: Le 04/11/2014 18:00, Johnny Lu a écrit : Hi. If my NVT simulation of a protein in 30k molecules of water has a pressure of 11 bar (error 0.5 bar from g_energy), will the dynamics (not distribution of conformations) change enough that the mechanism inferred from this simulation be significantly more unreliable than the mechanism inferred from a 1 bar simulation? (Will the reviewers cut my paper into ribbons?) Thanks again. Hi, Considering only your NVT parameters for your simulation, I would consider it totally irrelevant to talk about pressure where your constrain the volume. This value or any other one has not really a meaning in this situation, and I seen many variations in the pressure value in this microcanonical ensemble without paying too much attention on it. In an NPT simulation, then you should be able to find back a normal 1 bar simulation I think. Do you have any reason to do first an NPT simulation, and then an NVT one? I would personally let the system equilibrate in NVT, then swith to the more natural NPT, provided actual code and force fields are now good enough in this ensemble. Best, Stéphane -- Team Protein Design In Silico UFIP, UMR 6286 CNRS, UFR Sciences et Techniques, 2, rue de la Houssinière, Bât. 25, 44322 Nantes cedex 03, France Tél : +33 251 125 636 Fax : +33 251 125 632 http://www.ufip.univ-nantes.fr/ - http://www.steletch.org -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pseudo-random algorithm
Thanks for answering my question. On Wed, Oct 29, 2014 at 6:36 PM, Roland Schulz rol...@utk.edu wrote: Hi, Gromacs 5.0 uses a Mersenne twister. See gmx_random.h. Starting with 5.0 it uses Random123 threefry2x64. Why do you think your results are affected by the PRNG? Roland On Wed, Oct 29, 2014 at 6:23 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. Before I start to feel optimistic about my alanine tripeptide simulation, can I know which pseudo-random number algorithm does my installation of gromacs 4.6.6 use? It was installed on linux centos 5 with kernel 2.6.32-220.7.1.el6.x86_64, and the machine has 12 intel cpu and no gpu. I was using the V-rescale thermostat. Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- ORNL/UT Center for Molecular Biophysics cmb.ornl.gov 865-241-1537, ORNL PO BOX 2008 MS6309 -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Pressure Question
Hi. If my NVT simulation of a protein in 30k molecules of water has a pressure of 11 bar (error 0.5 bar from g_energy), will the dynamics (not distribution of conformations) change enough that the mechanism inferred from this simulation be significantly more unreliable than the mechanism inferred from a 1 bar simulation? (Will the reviewers cut my paper into ribbons?) Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] problems with testing a new gromacs installation (myfirst) for correctness
Hi. did you try to download the regression tests manually? I don't know if the problem that I encountered was the same one: http://comments.gmane.org/gmane.science.biology.gromacs.user/71882 I had to turn regression test download off in addition to setting path to regression test. On Sat, Nov 1, 2014 at 12:45 PM, infoseca i...@seca-tech.de wrote: hello my name is hans, i am a master student in biophysics at the lmu munich. first thanks a lot to all spending time to engage with my problem. my machine is configured as follows. processor intel i5 2450M 2,5 Ghz OS windows 7 64 bit linux emulation with cygwin x86_64 version 1.7.32 gromacs version is 5.0.2 i installed cygwin with the following packages beside the defaults. devel (gdn, gdb, make, cmake, gcc 4.9.0.1), shels(tcsh), editors (vi), lib(libxml2-devel 2.9.2.1, libboost,libgcc1 4.9.0.1) i have uninstalled the default fftw3 package from cygwin as recommended in the gromacs instruction. i unpacked gromacs in my default cygwin user folder = /home/gl/ the configuration and compiling shell script i used was cd gromacs-5.0.2 mkdir build cd build cmake .. -DGMX_BUILD_OWN_FFTW=ON -DGMX_EXTERNAL_BLAS=OFF -DGMX_EXTERNAL_LAPACK=OFF -DGMX_SIMD=SSE2 -DREGRESSIONTEST_DOWNLOAD=ON make make check i tried it several times with different cmake options with and without DGMX_EXTERNAL_BLAS=OFF -DGMX_EXTERNAL_LAPACK=OFF, with and without -DGMX_BUILD_OWN_FFTW=ON (if i did without this option i install the newest fftw3 version (3.0.2) before. but the result was always the same the configuration and the compilation works without any warning. but the testing provides a lot of errors and always the same result as shown in the test logs. i attached them to this email. i hope someone can help me. thanks and best regards hans -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
One less thing to worry about then. I will try to fix this in another way. Thanks. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
The averaged volume of the 1bar pressure NPT simulation over 150ns was very clearly 298.5 nm^3. But now, when I set the volume of the NVT simulation to 298.7 nm^3 by starting from a NPT frame that has the volume, the average was 1.2 bar with error estimate 0.53, over 52 ns. The same tactic also didn't work for a 300 ns NPT simulation and subsequently 300 ns NVT simulation. This NVT simulation pressure was averaged to be around 4 bar. Why starting a NVT simulation from a NPT frame with the averaged NPT volume didn't give the target pressure of 1 bar? On Sun, Oct 19, 2014 at 2:20 AM, Tsjerk Wassenaar tsje...@gmail.com wrote: Hi Johnny, The density is M/V. The only parameter changing with pressure coupling is V, so the density and volume are fully correlated. No surprise there. Cheers, Tsjerk On Oct 19, 2014 2:27 AM, Johnny Lu johnny.lu...@gmail.com wrote: The frames with density closest to the average density also have volumes closest to the averaged volume. On Sat, Oct 18, 2014 at 8:18 PM, Johnny Lu johnny.lu...@gmail.com wrote: I searched the energy file made by g_energy, and found that NPT frames with very similar densities have very similar volume. So, I guess using density is same as using volume in this case. On Sat, Oct 18, 2014 at 9:09 AM, Johnny Lu johnny.lu...@gmail.com wrote: Would manually setting the box size make vacuum bubbles? On Sat, Oct 18, 2014 at 9:08 AM, Johnny Lu johnny.lu...@gmail.com wrote: my bad. that formula for density is wrong. But I till don't see why using the same averaged density (instead of volume) for the NVT and NPT simulations would give a different result. On Sat, Oct 18, 2014 at 8:52 AM, Johnny Lu johnny.lu...@gmail.com wrote: Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
I saved .cpt file every minute. And using the xvg file generated by g_energy, I picked the .cpt file with the volume that I want, and then run a NVT simulation, continuing from thee NPT .cpt file. The volume of the .cpt file of the NPT simulation should be same as the volume of the NVT file. Is it so? Or manually setting the volume makes some magical differences? On Sun, Oct 19, 2014 at 10:24 AM, Johnny Lu johnny.lu...@gmail.com wrote: Thanks for answering my questions too. On Sun, Oct 19, 2014 at 10:18 AM, Johnny Lu johnny.lu...@gmail.com wrote: The averaged volume of the 1bar pressure NPT simulation over 150ns was very clearly 298.5 nm^3. But now, when I set the volume of the NVT simulation to 298.7 nm^3 by starting from a NPT frame that has the volume, the average was 1.2 bar with error estimate 0.53, over 52 ns. The same tactic also didn't work for a 300 ns NPT simulation and subsequently 300 ns NVT simulation. This NVT simulation pressure was averaged to be around 4 bar. Why starting a NVT simulation from a NPT frame with the averaged NPT volume didn't give the target pressure of 1 bar? On Sun, Oct 19, 2014 at 2:20 AM, Tsjerk Wassenaar tsje...@gmail.com wrote: Hi Johnny, The density is M/V. The only parameter changing with pressure coupling is V, so the density and volume are fully correlated. No surprise there. Cheers, Tsjerk On Oct 19, 2014 2:27 AM, Johnny Lu johnny.lu...@gmail.com wrote: The frames with density closest to the average density also have volumes closest to the averaged volume. On Sat, Oct 18, 2014 at 8:18 PM, Johnny Lu johnny.lu...@gmail.com wrote: I searched the energy file made by g_energy, and found that NPT frames with very similar densities have very similar volume. So, I guess using density is same as using volume in this case. On Sat, Oct 18, 2014 at 9:09 AM, Johnny Lu johnny.lu...@gmail.com wrote: Would manually setting the box size make vacuum bubbles? On Sat, Oct 18, 2014 at 9:08 AM, Johnny Lu johnny.lu...@gmail.com wrote: my bad. that formula for density is wrong. But I till don't see why using the same averaged density (instead of volume) for the NVT and NPT simulations would give a different result. On Sat, Oct 18, 2014 at 8:52 AM, Johnny Lu johnny.lu...@gmail.com wrote: Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
how long were those simulations? Were there enough time for the new ensemble to equilibrate, if you changed ensemble from NVE to NVT? On Sun, Oct 19, 2014 at 11:34 AM, Wade wad...@foxmail.com wrote: Dear Mark and Lu, Thank you very much for your responses. Based on your suggestions, I performed some tests: 1) I considered the influence of the time-step (with LINCS constraint), thermostat, and simulation precision in NVT simulation (tip4p water box, 300K, after 2ns NVE simulation). Below are results: --- Time-step (fs) thermostat (V or N) precision (S or D) drift/ns = delt E/av E*100% 0.1 V D 0.3 1 V D 2 2 V D 5.8 0.1 V S 80 1 V S 1.5 2 V S 6.4 0.1 N D 0.3 1 N D 2.5 2 N D 20 0.1 N S 76 1 N S 1.7 2 N S 11.5 -- Above results shown that no matter the v-rescale or nose-hoover thermostat, the conserved Energy has nearly no drift (~0.3%/ns) when an very small time-step (0.1 fs) has been employed. But, even with 0.1fs step length, the integration can only be conserved in the double precision simulations. For a commonly used time-step, such as 2 fs (with LINCS constraint), the drifts of the conserved energy are about 6-7% per ns. Such a drift might be not very significant in a short simulation. But, its accumulation in a long-time (e.g. several ns) simulation should be huge. 2) I checked the time-dependency of auxiliary dynamics purely, and found that it was the origination of the constant-rate drift of conserved energy. I also noticed that the exact solution of Eq.7 in bussi’s paper (Eq. A7) has been realized in gromacs to get the rescaling factor. But, I don’t know what the origination of the integration error is, and How can we deal with it. As Lu said, does it comes from the summation of dK? If yes, how can we deal with the drift when we use an affordable time-step in a long-time simulation? With best wishes, Wade -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
my bad. that formula for density is wrong. But I till don't see why using the same averaged density (instead of volume) for the NVT and NPT simulations would give a different result. On Sat, Oct 18, 2014 at 8:52 AM, Johnny Lu johnny.lu...@gmail.com wrote: Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
Would manually setting the box size make vacuum bubbles? On Sat, Oct 18, 2014 at 9:08 AM, Johnny Lu johnny.lu...@gmail.com wrote: my bad. that formula for density is wrong. But I till don't see why using the same averaged density (instead of volume) for the NVT and NPT simulations would give a different result. On Sat, Oct 18, 2014 at 8:52 AM, Johnny Lu johnny.lu...@gmail.com wrote: Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Check for Vacuum Bubbles Density
Hi. The NPT simulation has 9K TIP3P water with 173 amino acid residues and uses Amber99SB-ILDN force field, and use Berendsen barostat and V-rescale thermostat. I plan to run NVT with the same pressure an temperature after this. The average density is 1015 kg/m^3 over 35ns. The density was near 1015 over more than 300 ns, in previous NPT simulations. Statistics over 34744941 steps [ 0. through 34744.9400 ps ], 5 data sets All statistics are over 6948989 points Energy Average Err.Est. RMSD Tot-Drift --- Total Energy-307197210 880.41 -1408.29 (kJ/mol) Temperature 299.993 0.00371.70813 0.0273197 (K) Pressure1.00317 0.009138.426 -0.0381886 (bar) Volume 298.567 0.049 0.371817 -0.314958 (nm^3) Density 1014.8 0.171.263771.07078 (kg/m^3) This is higher than the 982.3 value in the mail-list [ https://www.mail-archive.com/gmx-users@gromacs.org/msg29327.html]. Why the density is different? I used a 1.0 nm cut off, following the force-field paper: Improved side-chain torsion potentials for the Amber ff99SB protein force field [ http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2970904/], but I also added dispersion correction. Should I not use dispersion correction? I look at the trajectory in VMD with periodic images turn on. But there were many water that overlap each other, and I can not see any vacuum bubble clearly (if there is a vacuum bubble) [ http://archive.ambermd.org/201103/0431.html]. Is there a better way to check for vacuum bubbles? I didn't know a long NVT equilibration at 300 K, right after minimization, can make vacuum bubbles. The NVT equilibration was 300 ps. I also didn't know that I should run berendsen barostat before Parrinello-Rahman, so those 300+ ns NPT simulations before this one all uses Parrinello-Rahman barostat. If there is no vacuum bubbles, I think I was just lucky. Below is the mdp file I used for the NPT simulation: title = NPT production ; Run parameters integrator = md-vv ; leap-frog integrator nsteps = 3600 ; 1 ns dt = 0.001 ; 1 fs ; Output control nstenergy = 10 ; save energies every 1.0 ps nstlog = 5000 ; update log file every 0.2 ps ; Bond parameters continuation= yes ; Restarting after NVT constraint_algorithm = lincs; holonomic constraints constraints = H-bonds ; all bonds (even heavy atom-H bonds) constrained lincs_iter = 2 ; accuracy of LINCS lincs_order = 4 ; also related to accuracy ; Neighborsearching ns_type = grid ; search neighboring grid cells nstlist = 10; 10 fs rlist = 1.0 ; short-range neighborlist cutoff (in nm) rcoulomb= 1.0 ; short-range electrostatic cutoff (in nm) rvdw= 1.0 ; short-range van der Waals cutoff (in nm) ; Electrostatics coulombtype = PME ; Particle Mesh Ewald for long-range electrostatics pme_order = 4 ; cubic interpolation fourierspacing = 0.1 ; grid spacing for FFT ; Temperature coupling is on tcoupl = V-rescale ; modified Berendsen thermostat tc-grps = system; single thermostat tau_t = 1.0 ; time constant, in ps ref_t = 300 ; reference temperature, one for each group, in K ; Pressure coupling is on pcoupl = berendsen ; Pressure coupling on in NPT pcoupltype = isotropic ; uniform scaling of box vectors tau_p = 2.0 ; time constant, in ps ref_p = 1.0 ; reference pressure, in bar compressibility = 4.5e-5; isothermal compressibility of water, bar^-1 refcoord_scaling = com ; Periodic boundary conditions pbc = xyz ; 3-D PBC ; Dispersion correction DispCorr= EnerPres ; account for cut-off vdW scheme ; Velocity generation gen_vel = no; Velocity generation is off cutoff-scheme = Verlet Thank you again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
For V-rescale thermostat, the bussi paper seems to say the tilde H is the integral of the auxiliary dynamics. Not sure if this is same as the conserved energy in gromacs, which is also the integral of the auxiliary dynamics. I guess numerical error causes the system to lose/gain total energy in a linear way. Rise/drop of tilde H may reflect the extra energy that the thermostat has to put in to compensate for this numerical error. [just my guess] If the energy of the system is conserved without the thermostat, tilde H should be constant... I guess. The Bussi paper at [ marge.uochb.cas.cz/~roesel/teach/Clanky/paper5_Bussi_v_rescale.pdf] says tilde H is the conserved quantity. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
Oh, integrating with rectangles under the curve causes error. I guess larger time-steps can cause error in tilde H by this method of integration alone. On Sat, Oct 18, 2014 at 11:25 AM, Johnny Lu johnny.lu...@gmail.com wrote: For V-rescale thermostat, the bussi paper seems to say the tilde H is the integral of the auxiliary dynamics. Not sure if this is same as the conserved energy in gromacs, which is also the integral of the auxiliary dynamics. I guess numerical error causes the system to lose/gain total energy in a linear way. Rise/drop of tilde H may reflect the extra energy that the thermostat has to put in to compensate for this numerical error. [just my guess] If the energy of the system is conserved without the thermostat, tilde H should be constant... I guess. The Bussi paper at [ marge.uochb.cas.cz/~roesel/teach/Clanky/paper5_Bussi_v_rescale.pdf] says tilde H is the conserved quantity. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
Does double precision cause a less drop/rise in tilde H over time, when compared to a mixed precision run under same condition ? On Sat, Oct 18, 2014 at 11:28 AM, Johnny Lu johnny.lu...@gmail.com wrote: Oh, integrating with rectangles under the curve causes error. I guess larger time-steps can cause error in tilde H by this method of integration alone. On Sat, Oct 18, 2014 at 11:25 AM, Johnny Lu johnny.lu...@gmail.com wrote: For V-rescale thermostat, the bussi paper seems to say the tilde H is the integral of the auxiliary dynamics. Not sure if this is same as the conserved energy in gromacs, which is also the integral of the auxiliary dynamics. I guess numerical error causes the system to lose/gain total energy in a linear way. Rise/drop of tilde H may reflect the extra energy that the thermostat has to put in to compensate for this numerical error. [just my guess] If the energy of the system is conserved without the thermostat, tilde H should be constant... I guess. The Bussi paper at [ marge.uochb.cas.cz/~roesel/teach/Clanky/paper5_Bussi_v_rescale.pdf] says tilde H is the conserved quantity. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Use NVT to mimic NVE
The conserved energy from g_energy, which I saw someone say is tilde H, drop more crazily if I use 1s coupling constant. On Mon, Oct 13, 2014 at 5:52 PM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, What is your target observable? What got worse? Mark On Mon, Oct 13, 2014 at 11:17 PM, Johnny Lu johnny.lu...@gmail.com wrote: The simulation get worse in a new way. I see that thermostat scales velocity and may not fix numerical error in potential energy. On Mon, Oct 13, 2014 at 2:07 PM, Johnny Lu johnny.lu...@gmail.com wrote: I just want something that will patch up the energy lost due to numerical error of NVE simulation of the system ran by mixed precision gromacs, instead of a thermostat. I hope the velocity rescaling is sufficiently uncorrelated with the motion of the protein. So far, the simulations ran 2.5 ns, and the fluctuation of total energy seems to be within 1% of total energy, with a 100ps or 1ns coupling constant. May be I should try a 10 ns coupling constant, just to see if the simulation would go belly up. On Mon, Oct 13, 2014 at 11:02 AM, Michael Shirts mrshi...@gmail.com wrote: I guess, if I pick a coupling constant that is just small enough to keep the energy conserved, I would get a NVT simulation that is as close as a NVE simulation as possible. Is this correct? Yes, but then at that point the thermostat isn't actually thermostatting. The Bussi comment is merely to show that his thermostat correctly reduces to Newton's law in the limit, not that it would be useful to run it in that limit. On Mon, Oct 13, 2014 at 10:28 AM, Johnny Lu johnny.lu...@gmail.com wrote: On page 014101-3, the Bussi paper ( http://dx.doi.org/10.1063/1.2408420) mentioned: On the other hand, for coupling constant approaching infinity,the Hamiltonian dynamics is recovered. Does that means that for a large enough coupling constant, the velocities are nearly not rescaled, and the dynamics (like rate of motion) would be same as that of NVE? A larger coupling constant, means a smaller diffusion coefficient in the axillary dynamics by equation 6. While the effects of the velocity rescaling at each step will accumulate, a larger coupling constant means the thermostat perturb less of the dynamics, and the resulting dynamics is closer to a NVE simulation. There is no worry that the thermostat would suddenly rescale the dynamics every x step, because in the procedure of the thermostat, the velocities are rescaled every step, regardless of the coupling constant. I guess, if I pick a coupling constant that is just small enough to keep the energy conserved, I would get a NVT simulation that is as close as a NVE simulation as possible. Is this correct? -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Use NVT to mimic NVE
I mean here seems to say conserved energy is tilde H [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 6:44 PM, Johnny Lu johnny.lu...@gmail.com wrote: The conserved energy from g_energy, which I saw someone say is tilde H, drop more crazily if I use 1s coupling constant. On Mon, Oct 13, 2014 at 5:52 PM, Mark Abraham mark.j.abra...@gmail.com wrote: Hi, What is your target observable? What got worse? Mark On Mon, Oct 13, 2014 at 11:17 PM, Johnny Lu johnny.lu...@gmail.com wrote: The simulation get worse in a new way. I see that thermostat scales velocity and may not fix numerical error in potential energy. On Mon, Oct 13, 2014 at 2:07 PM, Johnny Lu johnny.lu...@gmail.com wrote: I just want something that will patch up the energy lost due to numerical error of NVE simulation of the system ran by mixed precision gromacs, instead of a thermostat. I hope the velocity rescaling is sufficiently uncorrelated with the motion of the protein. So far, the simulations ran 2.5 ns, and the fluctuation of total energy seems to be within 1% of total energy, with a 100ps or 1ns coupling constant. May be I should try a 10 ns coupling constant, just to see if the simulation would go belly up. On Mon, Oct 13, 2014 at 11:02 AM, Michael Shirts mrshi...@gmail.com wrote: I guess, if I pick a coupling constant that is just small enough to keep the energy conserved, I would get a NVT simulation that is as close as a NVE simulation as possible. Is this correct? Yes, but then at that point the thermostat isn't actually thermostatting. The Bussi comment is merely to show that his thermostat correctly reduces to Newton's law in the limit, not that it would be useful to run it in that limit. On Mon, Oct 13, 2014 at 10:28 AM, Johnny Lu johnny.lu...@gmail.com wrote: On page 014101-3, the Bussi paper ( http://dx.doi.org/10.1063/1.2408420) mentioned: On the other hand, for coupling constant approaching infinity,the Hamiltonian dynamics is recovered. Does that means that for a large enough coupling constant, the velocities are nearly not rescaled, and the dynamics (like rate of motion) would be same as that of NVE? A larger coupling constant, means a smaller diffusion coefficient in the axillary dynamics by equation 6. While the effects of the velocity rescaling at each step will accumulate, a larger coupling constant means the thermostat perturb less of the dynamics, and the resulting dynamics is closer to a NVE simulation. There is no worry that the thermostat would suddenly rescale the dynamics every x step, because in the procedure of the thermostat, the velocities are rescaled every step, regardless of the coupling constant. I guess, if I pick a coupling constant that is just small enough to keep the energy conserved, I would get a NVT simulation that is as close as a NVE simulation as possible. Is this correct? -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
Does this old maillist post say tilde H is conserved energy? [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 12:46 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Sat, Oct 18, 2014 at 4:32 PM, Wade wad...@foxmail.com wrote: Dear Mark, Thank your very much for your reply. However, I still confused because results showed that the conserved En. was time dependent (with small fluctuation); but, the total energy in the ener file has small drift with high fluctuations. Both these things vary doesn't mean anything. Numbers, or it didn't happen ;-) Further, I rechecked the code (gmx-4.5.5) ?in these days, and I noticed a part of code might be useful (enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);). It will be actived when the leap-frog integrator is employed. To assure the the conserved En. is either H or H-tilde, I changed the code as this: enerd-term[F_ECONSERVED] = enerd-term[F_ETOT];. Result shown that the total energy and conserved En. are same now in the output of ener file?. Great. A = A... Dose it means that the conserved En. in ener file is H-tilde? ...which doesn't say what B is... The question is whether there's an intrinsic time dependence on the value returned by compute_conserved_from_auxiliary. You can only do that by removing the *other* term. ? If yes, why does the conserved En. drifted with a constant rate in a 10 ns ?simulation for a pure water box (216 tip4p water)? Because it's characteristic of the drift of your setup or of the implementation of what is reported as the conserved quantity. I suggested a diagnostic procedure. Did you try it? If not, why not? Mark With best wishes, Wade (part of the code please see below, I hope I have got the key point). ? ~ /* # BEGIN PREPARING EDR OUTPUT ### */ /* sum up the foreign energy and dhdl terms */ sum_dhdl(enerd,state-lambda,ir); /* use the directly determined last velocity, not actually the averaged half steps */if (bTrotter ir-eI==eiVV) {enerd-term[F_EKIN] = last_ekin; }enerd-term[F_ETOT] = enerd-term[F_EPOT] + enerd-term[F_EKIN];if (bVV){ enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + saved_conserved_quantity;}else { enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);? ~~ That could well be true. I did look carefully at the code earlier this year, and decided it was correct and wrote output of sensible things. However I don't remember whether the conserved quantity reported is H or H-tilde, and don't have time now to go back. But IIRC because one of them has a time dependence, you can run double-precision GROMACS in a conservative NVE setup and observe no drift, then add this thermostat, and from that run you will know which of H and H-tilde is reported as the conserved quantity. Mark Is that right? I really need your help. Any suggestion is valuable. Wade? -- -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
Figure 2 of the Bussi paper has a diagram with constant tilde H for NVT simulation with 2fs time step, and another one with rising tilde H for NVT simulation with 40fs timestep, and say: for tilde H in the NVT calculation. We notice that, while in the NVE calculation the system explodes at some point, the NVT calculation is always stable, thanks to the thermostat. However, in spite of the stability, the drift in tilde H indicates that thesampling is inaccurate under these conditions. So, tilde H should be constant even in a NVT simulation, and I don't exactly agree with the old mail-list post at [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 6:51 PM, Johnny Lu johnny.lu...@gmail.com wrote: Does this old maillist post say tilde H is conserved energy? [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 12:46 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Sat, Oct 18, 2014 at 4:32 PM, Wade wad...@foxmail.com wrote: Dear Mark, Thank your very much for your reply. However, I still confused because results showed that the conserved En. was time dependent (with small fluctuation); but, the total energy in the ener file has small drift with high fluctuations. Both these things vary doesn't mean anything. Numbers, or it didn't happen ;-) Further, I rechecked the code (gmx-4.5.5) ?in these days, and I noticed a part of code might be useful (enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);). It will be actived when the leap-frog integrator is employed. To assure the the conserved En. is either H or H-tilde, I changed the code as this: enerd-term[F_ECONSERVED] = enerd-term[F_ETOT];. Result shown that the total energy and conserved En. are same now in the output of ener file?. Great. A = A... Dose it means that the conserved En. in ener file is H-tilde? ...which doesn't say what B is... The question is whether there's an intrinsic time dependence on the value returned by compute_conserved_from_auxiliary. You can only do that by removing the *other* term. ? If yes, why does the conserved En. drifted with a constant rate in a 10 ns ?simulation for a pure water box (216 tip4p water)? Because it's characteristic of the drift of your setup or of the implementation of what is reported as the conserved quantity. I suggested a diagnostic procedure. Did you try it? If not, why not? Mark With best wishes, Wade (part of the code please see below, I hope I have got the key point). ? ~ /* # BEGIN PREPARING EDR OUTPUT ### */ /* sum up the foreign energy and dhdl terms */ sum_dhdl(enerd,state-lambda,ir); /* use the directly determined last velocity, not actually the averaged half steps */if (bTrotter ir-eI==eiVV) {enerd-term[F_EKIN] = last_ekin; }enerd-term[F_ETOT] = enerd-term[F_EPOT] + enerd-term[F_EKIN];if (bVV){ enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + saved_conserved_quantity;}else { enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);? ~~ That could well be true. I did look carefully at the code earlier this year, and decided it was correct and wrote output of sensible things. However I don't remember whether the conserved quantity reported is H or H-tilde, and don't have time now to go back. But IIRC because one of them has a time dependence, you can run double-precision GROMACS in a conservative NVE setup and observe no drift, then add this thermostat, and from that run you will know which of H and H-tilde is reported as the conserved quantity. Mark Is that right? I really need your help. Any suggestion is valuable. Wade? -- -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
The bussi paper is at [ marge.uochb.cas.cz/~roesel/teach/Clanky/paper5_Bussi_v_rescale.pdf http://marge.uochb.cas.cz/%7Eroesel/teach/Clanky/paper5_Bussi_v_rescale.pdf ]. I seem to vaguely remember someone wrote if tilde H drop linearly, it means the energy is conserved. But I'm not sure now. On Sat, Oct 18, 2014 at 6:58 PM, Johnny Lu johnny.lu...@gmail.com wrote: Figure 2 of the Bussi paper has a diagram with constant tilde H for NVT simulation with 2fs time step, and another one with rising tilde H for NVT simulation with 40fs timestep, and say: for tilde H in the NVT calculation. We notice that, while in the NVE calculation the system explodes at some point, the NVT calculation is always stable, thanks to the thermostat. However, in spite of the stability, the drift in tilde H indicates that thesampling is inaccurate under these conditions. So, tilde H should be constant even in a NVT simulation, and I don't exactly agree with the old mail-list post at [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 6:51 PM, Johnny Lu johnny.lu...@gmail.com wrote: Does this old maillist post say tilde H is conserved energy? [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 12:46 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Sat, Oct 18, 2014 at 4:32 PM, Wade wad...@foxmail.com wrote: Dear Mark, Thank your very much for your reply. However, I still confused because results showed that the conserved En. was time dependent (with small fluctuation); but, the total energy in the ener file has small drift with high fluctuations. Both these things vary doesn't mean anything. Numbers, or it didn't happen ;-) Further, I rechecked the code (gmx-4.5.5) ?in these days, and I noticed a part of code might be useful (enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);). It will be actived when the leap-frog integrator is employed. To assure the the conserved En. is either H or H-tilde, I changed the code as this: enerd-term[F_ECONSERVED] = enerd-term[F_ETOT];. Result shown that the total energy and conserved En. are same now in the output of ener file?. Great. A = A... Dose it means that the conserved En. in ener file is H-tilde? ...which doesn't say what B is... The question is whether there's an intrinsic time dependence on the value returned by compute_conserved_from_auxiliary. You can only do that by removing the *other* term. ? If yes, why does the conserved En. drifted with a constant rate in a 10 ns ?simulation for a pure water box (216 tip4p water)? Because it's characteristic of the drift of your setup or of the implementation of what is reported as the conserved quantity. I suggested a diagnostic procedure. Did you try it? If not, why not? Mark With best wishes, Wade (part of the code please see below, I hope I have got the key point). ? ~ /* # BEGIN PREPARING EDR OUTPUT ### */ /* sum up the foreign energy and dhdl terms */ sum_dhdl(enerd,state-lambda,ir); /* use the directly determined last velocity, not actually the averaged half steps */if (bTrotter ir-eI==eiVV) {enerd-term[F_EKIN] = last_ekin; }enerd-term[F_ETOT] = enerd-term[F_EPOT] + enerd-term[F_EKIN];if (bVV){ enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + saved_conserved_quantity;}else { enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);? ~~ That could well be true. I did look carefully at the code earlier this year, and decided it was correct and wrote output of sensible things. However I don't remember whether the conserved quantity reported is H or H-tilde, and don't have time now to go back. But IIRC because one of them has a time dependence, you can run double-precision GROMACS in a conservative NVE setup and observe no drift, then add this thermostat, and from that run you will know which of H and H-tilde is reported as the conserved quantity. Mark Is that right? I really need your help. Any suggestion is valuable. Wade? -- -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please
Re: [gmx-users] Conserved energy (Conserved En.) in NVT simulation (Wade)
From Bussi paper: If we use this analysis and go to the limit of an infinitesimal time step, we find [Equation 15] where the last two terms come from the integration of Eq. 7 along the trajectory. Note that a similar integration along the path is present in H_{Nosé}. However, in our scheme a stochastic integration is also necessary. In the continuum limit the changes in energy induced by the rescaling compensate exactly the fluctuations in H. For a finite time step this compensation is only approximate and the conservation of tilde{H} provides a measure on the accuracy of the integration. This accuracy has to be interpreted in the sense of the ability of generating configurations representative of the ensemble. The physical meaning of Eq. 15 is that the fluxes of energy between the system and the thermostat are exactly balanced. Does that mean even with a finite timestep, if the conformations in the trajectory are all correctly sampled from the intended ensemble without any biases, tilde H should still be constant? It is a bit unfortunate that they didn't say how the drift rate of tilde H related to deviation of distribution of conformations from the intended ensemble. On Sat, Oct 18, 2014 at 7:02 PM, Johnny Lu johnny.lu...@gmail.com wrote: The bussi paper is at [ marge.uochb.cas.cz/~roesel/teach/Clanky/paper5_Bussi_v_rescale.pdf http://marge.uochb.cas.cz/%7Eroesel/teach/Clanky/paper5_Bussi_v_rescale.pdf ]. I seem to vaguely remember someone wrote if tilde H drop linearly, it means the energy is conserved. But I'm not sure now. On Sat, Oct 18, 2014 at 6:58 PM, Johnny Lu johnny.lu...@gmail.com wrote: Figure 2 of the Bussi paper has a diagram with constant tilde H for NVT simulation with 2fs time step, and another one with rising tilde H for NVT simulation with 40fs timestep, and say: for tilde H in the NVT calculation. We notice that, while in the NVE calculation the system explodes at some point, the NVT calculation is always stable, thanks to the thermostat. However, in spite of the stability, the drift in tilde H indicates that thesampling is inaccurate under these conditions. So, tilde H should be constant even in a NVT simulation, and I don't exactly agree with the old mail-list post at [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 6:51 PM, Johnny Lu johnny.lu...@gmail.com wrote: Does this old maillist post say tilde H is conserved energy? [ https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083330.html ] On Sat, Oct 18, 2014 at 12:46 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Sat, Oct 18, 2014 at 4:32 PM, Wade wad...@foxmail.com wrote: Dear Mark, Thank your very much for your reply. However, I still confused because results showed that the conserved En. was time dependent (with small fluctuation); but, the total energy in the ener file has small drift with high fluctuations. Both these things vary doesn't mean anything. Numbers, or it didn't happen ;-) Further, I rechecked the code (gmx-4.5.5) ?in these days, and I noticed a part of code might be useful (enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + compute_conserved_from_auxiliary(ir,state,MassQ);). It will be actived when the leap-frog integrator is employed. To assure the the conserved En. is either H or H-tilde, I changed the code as this: enerd-term[F_ECONSERVED] = enerd-term[F_ETOT];. Result shown that the total energy and conserved En. are same now in the output of ener file?. Great. A = A... Dose it means that the conserved En. in ener file is H-tilde? ...which doesn't say what B is... The question is whether there's an intrinsic time dependence on the value returned by compute_conserved_from_auxiliary. You can only do that by removing the *other* term. ? If yes, why does the conserved En. drifted with a constant rate in a 10 ns ?simulation for a pure water box (216 tip4p water)? Because it's characteristic of the drift of your setup or of the implementation of what is reported as the conserved quantity. I suggested a diagnostic procedure. Did you try it? If not, why not? Mark With best wishes, Wade (part of the code please see below, I hope I have got the key point). ? ~ /* # BEGIN PREPARING EDR OUTPUT ### */ /* sum up the foreign energy and dhdl terms */ sum_dhdl(enerd,state-lambda,ir); /* use the directly determined last velocity, not actually the averaged half steps */if (bTrotter ir-eI==eiVV) {enerd-term[F_EKIN] = last_ekin; }enerd-term[F_ETOT] = enerd-term[F_EPOT] + enerd-term[F_EKIN];if (bVV){ enerd-term[F_ECONSERVED] = enerd-term[F_ETOT] + saved_conserved_quantity;}else
Re: [gmx-users] pressure dependence on volume.
I searched the energy file made by g_energy, and found that NPT frames with very similar densities have very similar volume. So, I guess using density is same as using volume in this case. On Sat, Oct 18, 2014 at 9:09 AM, Johnny Lu johnny.lu...@gmail.com wrote: Would manually setting the box size make vacuum bubbles? On Sat, Oct 18, 2014 at 9:08 AM, Johnny Lu johnny.lu...@gmail.com wrote: my bad. that formula for density is wrong. But I till don't see why using the same averaged density (instead of volume) for the NVT and NPT simulations would give a different result. On Sat, Oct 18, 2014 at 8:52 AM, Johnny Lu johnny.lu...@gmail.com wrote: Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
The frames with density closest to the average density also have volumes closest to the averaged volume. On Sat, Oct 18, 2014 at 8:18 PM, Johnny Lu johnny.lu...@gmail.com wrote: I searched the energy file made by g_energy, and found that NPT frames with very similar densities have very similar volume. So, I guess using density is same as using volume in this case. On Sat, Oct 18, 2014 at 9:09 AM, Johnny Lu johnny.lu...@gmail.com wrote: Would manually setting the box size make vacuum bubbles? On Sat, Oct 18, 2014 at 9:08 AM, Johnny Lu johnny.lu...@gmail.com wrote: my bad. that formula for density is wrong. But I till don't see why using the same averaged density (instead of volume) for the NVT and NPT simulations would give a different result. On Sat, Oct 18, 2014 at 8:52 AM, Johnny Lu johnny.lu...@gmail.com wrote: Was the density calculated by # particles / volume ? If so, using volume (as I did), and using density would give the same wrong pressure, upon transitioning from NPT to NVT. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Not achieving any speedup using Open MPI
i heard that mixing mpi and open mp together is bad idea (run more slow), unless the simulation has large number of atoms, and use many cpu. May be comparing gromacs running on a single computer, with and without openmp will show a difference in speed. On Fri, Oct 17, 2014 at 10:05 AM, Da-Wei Li lida...@gmail.com wrote: For a system with only ~20K atoms and you are using normal LAN, I feel your result is not unexpected. dawei On Fri, Oct 17, 2014 at 9:20 AM, Rytis Slatkevičius ryti...@gmail.com wrote: Hello, first of all: I am not a scientist, but rather an IT person trying to set up Gromacs for fellow scientists. My goal is to set up Gromacs on several local computers (connected with 1gbps LAN) and achieve some speedup of our runs using MPI. I have installed Gromacs 5.0.2 from Debian repository (package gromacs-openmpi). I can run Gromacs over multiple computers, I see processes being spooled up, so MPI itself is working. However, I am not seeing any speedup at all - in fact, I get a significant slowdown. When running on a rather old dualcore laptop, I can finish a d.lzm run from http://www.gromacs.org/About_Gromacs/Benchmarks within 109s or so. If I add a quadcore machine into the mix, I would expect the computation to be much faster - but instead I finish everything within 139 seconds! The quadcore can finish the job in 45 seconds when running on its own without Open MPI. I can't wrap my head around what I am doing wrong. My command line is: mpirun --display-map --hostfile hosts mdrun_mpi -v -deffnm d.lzm -dlb yes Any help would be appreciated. -- Pagarbiai / Sincerely Rytis Slatkevičius +370 670 7 -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] pressure dependence on volume.
Hi. Mainly TIP3P water, 300K. The pressure is near 1 bar. A less than 1% error in volume would cause how much error in average pressure? From three npt simulations of 72 ns with Berendsen barostat, I get the average volume is 298.5 nm^3. Continuing from a frame with volume very close to 298.5 nm^3 (~0.01 deviation from this volume), I run NVT simulation that at first gives a system that doesn't seem to be at equilibrium. Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
At least for real water, a 0.2% error in volume can mean the pressure is ~30 bar when the target pressure is 1 bar. http://docs.engineeringtoolbox.com/documents/309/water-density-temperature-pressure_2.png On Fri, Oct 17, 2014 at 10:49 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. Mainly TIP3P water, 300K. The pressure is near 1 bar. A less than 1% error in volume would cause how much error in average pressure? From three npt simulations of 72 ns with Berendsen barostat, I get the average volume is 298.5 nm^3. Continuing from a frame with volume very close to 298.5 nm^3 (~0.01 deviation from this volume), I run NVT simulation that at first gives a system that doesn't seem to be at equilibrium. Thanks again. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure dependence on volume.
I am trying to transit from NPT to NVT. Using the averaged volume of NPT for NVT somehow didn't give me the 1 bar pressure in NVT. I don't know why that happened. Was it the difference between constant pressure and constant volume heat capacity? But then, the thermostat should take care of that quite quickly. After that, N, V, and T would be same for NPT simulation and the NVT simulation... which means the pressure should be the same. Both the NVT and NPT uses the V-rescale thermostat, and the NPT uses Berendsen barostat. Right now I'm selecting NPT frames with different volumes, and see if the NVT simulations continuing from those frames would give me the 1 bar pressure. On Fri, Oct 17, 2014 at 3:53 PM, Justin Lemkul jalem...@vt.edu wrote: On 10/17/14 11:49 AM, Johnny Lu wrote: At least for real water, a 0.2% error in volume can mean the pressure is ~30 bar when the target pressure is 1 bar. http://docs.engineeringtoolbox.com/documents/309/water-density- temperature-pressure_2.png On Fri, Oct 17, 2014 at 10:49 AM, Johnny Lu johnny.lu...@gmail.com wrote: Hi. Mainly TIP3P water, 300K. The pressure is near 1 bar. A less than 1% error in volume would cause how much error in average pressure? From three npt simulations of 72 ns with Berendsen barostat, I get the average volume is 298.5 nm^3. Continuing from a frame with volume very close to 298.5 nm^3 (~0.01 deviation from this volume), I run NVT simulation that at first gives a system that doesn't seem to be at equilibrium. Does that time point correspond to the desired pressure? The pressure tensor is calculated from the virial and the kinetic energy, so those are the quantities you should be looking at for instantaneous pressures. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 629 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Understanding comments in pdb2gmx output
Does the pdb file have alternative conformations for some side chains or atoms? Like a side chain may have 50% chance to be rotated left, and 50% chance to be rotated right. The crystallographer recognized these two possibilities, and give each possibility a 0.5 occupancy. It may look like LYSA LYSB with A for one conformation, and B for another conformation. On Fri, Oct 17, 2014 at 6:08 PM, Agnivo Gosai agnivogromac...@gmail.com wrote: Dear Gromacs Users I am working with a complex of Human Thrombin - DNA aptamer ( pdb id 1HAO ) . I am using GROMACS 4.5.7 having the force field AMBER99SB-ParmBSC0 ported into it. I had cleaned the PDB file off crystal waters and a small chemical ligand ( which I dont require ) before passing it through pdb2gmx. The topology has been successfully generated. However I am concerned with the following comments in the output of pdb2gmx , I am copy pasting 3 blocks from the output :- # There are 3 chains and 0 blocks of water and 247 residues with 2590 atoms chain #res #atoms 1 'D'15315 2 'L'27222 3 'H' 253 2053 WARNING: there were 0 atoms with zero occupancy and 9 atoms with occupancy unequal to one (out of 2590 atoms). Check your pdb file. # Processing chain 3 'H' (2053 atoms, 253 residues) Analysing hydrogen-bonding network for automated assignment of histidine protonation. 395 donors and 366 acceptors were found. There are 535 hydrogen bonds Will use HISE for residue 57 Will use HISE for residue 71 Will use HISE for residue 91 Will use HISE for residue 119 Will use HISE for residue 230 Now there are 253 residues with 4078 atoms Chain time... Making bonds... Warning: Long Bond (2429-2431 = 0.805851 nm) Number of bonds was 4137, now 4136 ##3 I would like to know the meaning of these messages. Also I am reading the GROMACS manual for further info. Best , Agnivo Iowa State , USA -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] How to add iron parameter?
Pure md doesn't deal with complex orbitals well, I guess. Hydrogen bonds in pure md is not directional, as it should be. can molecular dynamics (md) simulate heavy metals, like iron, which have d oribtals? I heard that even calcium is a bit troublesome in md. On Wed, Oct 15, 2014 at 1:22 PM, Guangyu Zhu g...@hwi.buffalo.edu wrote: Hi, I’m a beginner of gromacs. I want to do simulation for a protein with protein with ferrous or ferric. But there is no iron in force field. What is easiest way to do it? Can I just add a few lines to aminocids.rtp, like this? [FE] [ atoms] FE FE3.0 [ bonds] [ angles ] [ impropers ] [ dihedrals ] Thanks! Guangyu -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.