SE2D U1477 Abend
On executing an IMS conversation I'm getting this abend: SE2DCompiler noted E-level error in program. Any idea what it means? Thanks. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
z/OS messages libraries ?
Hi all, I'd like to have access to z/OS messages libraries in order to get a message using its code then display both in case of abend (I trap the abend and the OS does not display anything). Where and how do I get those messages ? thanks. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
z/OS messages libraries - continued
Actually I found SYS1.MSGENU library which seems to contain all OS messages, only I don't know how to get the message code from a program. Anybody help me? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: z/OS messages libraries - continued
thanks Lizette. Actually I use CEE callable service to handle abends and it gives me a code 32xx so I'd like to get the corresponding message. example : 3209 Fixed-point divide exception -- this message ?? refer to page 228 in z/OS V1R9.0 Language Environment Programming Reference On Tue, 4 Mar 2008 10:02:01 -0500, Lizette Koehler [EMAIL PROTECTED] wrote: Francois, That is an ISPF Message Skeleton Library. Therefore you would have amp;vars that would not be resolved. I am not sure that is exactly what you need. The library is setup with message prefixes but not all messages are in this library. Lizette Actually I found SYS1.MSGENU library which seems to contain all OS messages, only I don't know how to get the message code from a program. Anybody help me? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: z/OS messages libraries - continued
Thanks much, I'll try that and let you know. On Tue, 4 Mar 2008 15:41:16 -, Flint, Mike [EMAIL PROTECTED] wrote: For LE messages, can't you use CEEMGET to convert a condition token to text (although not all messages are trapped in this way...)? -Original Message- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Francois Guillez Sent: 04 March 2008 15:29 To: IBM-MAIN@BAMA.UA.EDU Subject: Re: z/OS messages libraries - continued thanks Lizette. Actually I use CEE callable service to handle abends and it gives me a code 32xx so I'd like to get the corresponding message. example : 3209 Fixed-point divide exception -- this message ?? refer to page 228 in z/OS V1R9.0 Language Environment Programming Reference On Tue, 4 Mar 2008 10:02:01 -0500, Lizette Koehler [EMAIL PROTECTED] wrote: Francois, That is an ISPF Message Skeleton Library. Therefore you would have amp;vars that would not be resolved. I am not sure that is exactly what you need. The library is setup with message prefixes but not all messages are in this library. Lizette Actually I found SYS1.MSGENU library which seems to contain all OS messages, only I don't know how to get the message code from a program. Anybody help me? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This e-mail has come from Experian, the only business to have been twice named the UK's 'Business of the Yearâ Have you read our new resource on Affinity Marketing 'Everybody is Somebody's Customer' where we share our experience of managing successful affinity campaigns? Download from www.experianim.com/affinitymarketing (simply paste the URL into your web browser) == Information in this e-mail and any attachments is confidential, and may not be copied or used by anyone other than the addressee, nor disclosed to any third party without our permission. There is no intention to create any legally binding contract or other binding commitment through the use of this electronic communication unless it is issued in accordance with the Experian Limited standard terms and conditions of purchase or other express written agreement between Experian Limited and the recipient. Although Experian has taken reasonable steps to ensure that this communication and any attachments are free from computer virus, you are advised to take your own steps to ensure that they are actually virus free. Companies Act information: Registered name: Experian Limited Registered office: Talbot House, Talbot Street, Nottingham NG80 1TH Place of registration: England and Wales Registered number: 653331 -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: z/OS messages libraries - continued
It's been hard but it worked eventually, I got the message :) Thanks to all who replied, I have another question about CEE callable service to handle abends: besides a message number, it gives me an 'offset', does anybody know what offset it is, and from what address? On Tue, 4 Mar 2008 15:41:16 -, Flint, Mike [EMAIL PROTECTED] wrote: For LE messages, can't you use CEEMGET to convert a condition token to text (although not all messages are trapped in this way...)? -Original Message- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Francois Guillez Sent: 04 March 2008 15:29 To: IBM-MAIN@BAMA.UA.EDU Subject: Re: z/OS messages libraries - continued thanks Lizette. Actually I use CEE callable service to handle abends and it gives me a code 32xx so I'd like to get the corresponding message. example : 3209 Fixed-point divide exception -- this message ?? refer to page 228 in z/OS V1R9.0 Language Environment Programming Reference On Tue, 4 Mar 2008 10:02:01 -0500, Lizette Koehler [EMAIL PROTECTED] wrote: Francois, That is an ISPF Message Skeleton Library. Therefore you would have amp;vars that would not be resolved. I am not sure that is exactly what you need. The library is setup with message prefixes but not all messages are in this library. Lizette Actually I found SYS1.MSGENU library which seems to contain all OS messages, only I don't know how to get the message code from a program. Anybody help me? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This e-mail has come from Experian, the only business to have been twice named the UK's 'Business of the Yearâ Have you read our new resource on Affinity Marketing 'Everybody is Somebody's Customer' where we share our experience of managing successful affinity campaigns? Download from www.experianim.com/affinitymarketing (simply paste the URL into your web browser) = = Information in this e-mail and any attachments is confidential, and may not be copied or used by anyone other than the addressee, nor disclosed to any third party without our permission. There is no intention to create any legally binding contract or other binding commitment through the use of this electronic communication unless it is issued in accordance with the Experian Limited standard terms and conditions of purchase or other express written agreement between Experian Limited and the recipient. Although Experian has taken reasonable steps to ensure that this communication and any attachments are free from computer virus, you are advised to take your own steps to ensure that they are actually virus free. Companies Act information: Registered name: Experian Limited Registered office: Talbot House, Talbot Street, Nottingham NG80 1TH Place of registration: England and Wales Registered number: 653331 -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html