Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Jaime Solorza
osguyswirel...@gmail.com> > *To: *"Animal Farm" <af@afmug.com> > *Sent: *Thursday, January 25, 2018 9:19:18 PM > *Subject: *Re: [AFMUG] First Heat Map captures > > They are recommending UAP-LR in documentation but the icon is that in-wall > version in their dr

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Faisal Imtiaz
l.com> > To: "Animal Farm" <af@afmug.com> > Sent: Thursday, January 25, 2018 9:19:18 PM > Subject: Re: [AFMUG] First Heat Map captures > They are recommending UAP-LR in documentation but the icon is that in-wall > version in their drawing...I will verify with my cont

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Faisal Imtiaz
desk: (305)663-5518 Option 2 or Email: supp...@snappytelecom.net > From: "Jaime Solorza" <losguyswirel...@gmail.com> > To: "Animal Farm" <af@afmug.com> > Sent: Thursday, January 25, 2018 9:11:44 PM > Subject: Re: [AFMUG] First Heat Map captures > Th

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Jaime Solorza
They are recommending UAP-LR in documentation but the icon is that in-wall version in their drawing...I will verify with my contact tomorrow. The UAP versions have worked out great for me in schools and offices. Thanks for heads up. . Jaime Solorza On Jan 25, 2018 7:11 PM, "Jaime Solorza"

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Jaime Solorza
That's not not what they looked like in picture i saw on proposal...let me double check... thanks Jaime Solorza On Jan 25, 2018 7:07 PM, "Josh Reynolds" wrote: > Because In-WALLs go in outlet boxes. They're made for hotel rooms, > covering teeny tiny spaces. Because

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Josh Reynolds
I'm not here to argue with you Jaime :) You do what you find works! Enjoy your tecate. On Thu, Jan 25, 2018 at 8:07 PM, Josh Reynolds wrote: > Because In-WALLs go in outlet boxes. They're made for hotel rooms, > covering teeny tiny spaces. Because of this, they have very

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Josh Reynolds
Because In-WALLs go in outlet boxes. They're made for hotel rooms, covering teeny tiny spaces. Because of this, they have very poor antenna characteristics. Good for a small/short room, not good for a warehouse. ​ On Thu, Jan 25, 2018 at 7:59 PM, Jaime Solorza

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Josh Reynolds
Wall APs? I hope they're not trying to do this with the UniFi IN-WALL On Thu, Jan 25, 2018 at 7:21 PM, Jaime Solorza wrote: > I understand your point...I am told they will use UniFi Wall APsI am > going to buy one and learn it inside out...my bid includes fine

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Jaime Solorza
I understand your point...I am told they will use UniFi Wall APsI am going to buy one and learn it inside out...my bid includes fine tuning what the installation team deploys. Jaime Solorza On Jan 25, 2018 6:08 PM, "Josh Reynolds" wrote: > "used three APs > Ruckus,

Re: [AFMUG] First Heat Map captures

2018-01-25 Thread Josh Reynolds
"used three APs Ruckus, Ubiquiti in 2.4 and 5Ghz set to 20dBm..." I'm not worried about what the mobile device sees, I'm worried about what the AP sees from the mobile device. If it's set to 20dBm, you need to think about considering adjusting for antenna antenna gain and how that's going to

Re: [AFMUG] First Heat Map captures

2018-01-24 Thread Josh Reynolds
Power waaay too high. On Jan 24, 2018 1:31 PM, "Jaime Solorza" wrote: > Spent three hours...that's my son under tripod...used three APs > Ruckus, Ubiquiti in 2.4 and 5Ghz set to 20dBm... > > Jaime Solorza >