Re: Barcode support outside of chg-scsi

2001-02-02 Thread Jason Hollinden
Ok, I'm a few steps closer to adding barcode support to a modified chg-zd-mtx script. I have a two questions for some people in the know. chg-scsi has the following params: ./chg-scsi-slot ./chg-scsi-info ./chg-scsi-reset ./chg-scsi-eject ./chg-scsi

Re: Barcode support outside of chg-scsi

2001-02-02 Thread Doug Munsinger
Jason - Yes - [amanda@ford amanda]$ amtape daily slot 13 amtape: could not load slot 0: illegal request But with the change in code this now works. Much thanks for pointing this out. --doug At 08:04 AM 2/2/2001 -0500, you wrote: >On Fri, 02 Feb 2001, Doug Munsinger wrote: > > > I'm testing

Re: Barcode support outside of chg-scsi

2001-02-01 Thread Jason Hollinden
That's essentially the same things I had to do, the timeout and the changing of the wording returned from mtx. The only other thing I had to change was the case test at line that read: [$firstslot-$lastslot]) load=$1 ;; Because of the wording of the [test]), the highest

Re: Barcode support outside of chg-scsi

2001-02-01 Thread Doug Munsinger
Jason - having just been through "changer hell" I'm copying some mail I just sent to Joe Rhett re: chg-zd-mtx and barcodes - MAYBE it will help resolve what you are going through now. I fought with chg-scsi and chg-zd-mtx for about a week before dropping back and getting chg-manual to fully wo

Barcode support outside of chg-scsi

2001-02-01 Thread Jason Hollinden
After several days of searching, reading, and cussing, I am posting my woes in the hopes someone has some insight to using barcodes. Just for background, I have a Dell Poweredge-2400 with RedHat 6.2, running amanda-2.4.2p1. My tape library is an ADIC Scalar 100 hanging off a dedicated Adaptec