Re: multiple LTOs in the same library

2023-05-19 Thread Exuvo
You can probably skip the labelstr completly and only use autolabeling=no with manual labeling to assign tapes to each storage pool. Anton "exuvo" Olsson ex...@exuvo.se On 2023-05-19 13:36, ASV wrote: Wow, I'll go through it as soon as I can. Thank you very much for now exuvo, very

Re: multiple LTOs in the same library

2023-05-19 Thread ASV
Wow, I'll go through it as soon as I can. Thank you very much for now exuvo, very appreciated! On Thu, 2023-05-18 at 12:13 +0200, Exuvo wrote: > Here is the relevant part of my config with multiple separated tapes > (all LTO5 in my case) in the same MSL2024. > This relies on you having labeled

Re: multiple LTOs in the same library

2023-05-18 Thread Exuvo
Here is the relevant part of my config with multiple separated tapes (all LTO5 in my case) in the same MSL2024. This relies on you having labeled the tapes reasonably as it looks like labelstr can not match the LTO type. I do not use autolabeling, only manual labeling with a script i run when i

Re: multiple LTOs in the same library

2023-05-17 Thread ASV
That's correct, all drives are LTO8, but not all tapes. And no, there is no definition of any kind for slot positioning of the LTO7 right now. Thanks for your reply. On Tue, 2023-05-16 at 16:48 +0200, Stefan G. Weichinger wrote: > Am 16.05.23 um 16:34 schrieb ASV: > > Thanks exuvo, I'll try to

Re: multiple LTOs in the same library

2023-05-16 Thread Stefan G. Weichinger
Am 16.05.23 um 16:34 schrieb ASV: Thanks exuvo, I'll try to dig a bit in that direction even though I was expecting some built-in functionality for that. Are the LTO7-tapes always in defined slots? As far as I understand all *drives* are LTO8, but not all *tapes* ?

Re: multiple LTOs in the same library

2023-05-16 Thread ASV
Thanks exuvo, I'll try to dig a bit in that direction even though I was expecting some built-in functionality for that. On Tue, 2023-05-16 at 12:16 +0200, Exuvo wrote: > I think the settings you want are two different storage/pools > sections with a labelstr regex for matching valid tapes for

Re: multiple LTOs in the same library

2023-05-16 Thread Exuvo
I think the settings you want are two different storage/pools sections with a labelstr regex for matching valid tapes for it. I cant see my config from my phone but its something like that. On Tue, 16 May 2023, 11:17 ASV, wrote: > OK! I guess you have no hint for me but thanks anyway for

Re: multiple LTOs in the same library

2023-05-16 Thread ASV
OK! I guess you have no hint for me but thanks anyway for giving a sign. On Tue, 2023-05-16 at 11:01 +0200, Kees Meijs | Nefos wrote: > Yes. > > On 16-05-2023 10:40, ASV wrote: > > This mailing list seems dead. Is anybody actually still reading it? >

Re: multiple LTOs in the same library

2023-05-16 Thread Diego Zuccato
Someone is reading it. Maybe nobody knows the answer... Diego Il 16/05/2023 10:40, ASV ha scritto: This mailing list seems dead. Is anybody actually still reading it? ___ Hello everyone, I have an Amanda setup nicely working with a SpectraStack. The drives are LTO8 but I've just

multiple LTOs in the same library

2023-05-16 Thread ASV
This mailing list seems dead. Is anybody actually still reading it? ___ Hello everyone, I have an Amanda setup nicely working with a SpectraStack. The drives are LTO8 but I've just figured out that there are several LTO7 too in the library. Now I've both types defined in amanda.conf

multiple LTOs in the same library

2023-05-11 Thread ASV
Hello everyone, I have an Amanda setup nicely working with a SpectraStack. The drives are LTO8 but I've just figured out that there are several LTO7 too in the library. Now I've both types defined in amanda.conf however I cannot find a way to tell Amanda that tape labelled XXX or with the barcode