Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-28 Thread K Post
More notes and questions that might be of interest based on what I've witnessed: Yesterday, I improved my script to update an included IP list file ONLY when there is an IP change detected. I ran the script fresh, then restarted ASSP. No main thread stuck warnings for several hours. ASSP

Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-27 Thread K Post
> Apart from the fact that the MaintThread (1) does not store the file time correctly for 'Groups' included files (which will be fixed), Okay, at least that explains why it was trying to reload every 5 minutes. Hopefully the fix in the ASSP code combined with mine (see below) to stop my

Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-27 Thread Thomas Eckardt
Apart from the fact that the MaintThread (1) does not store the file time correctly for 'Groups' included files (which will be fixed), everything else you asked is answered in the GUI for an IT prof. Every security related content is encryped or not shown by assp. >I just saw this again in

Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-27 Thread K Post
Looking more at these include files in my groups definition. If I open them in the OS immediately after they're generated, it looks as expected. Something like: # # Generated by WriteFile-GetDomainIPSFromSPF.pl # 198.2.128.0/24 FROMSPF: spf.mandrillapp.com 198.2.132.0/22 FROMSPF:

Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-26 Thread K Post
That's helpful Thomas, thank you. I've clearly got more digging to do, and I will, but I could use more guidance on what I've found so far if you have the time. 1) *ConfigChangeTLSPorts->(TLStoProxyListenPorts,'',,Initializing)* I just saw this again in the statusassp gui 1 33 s call to

Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-26 Thread Thomas Eckardt
>I tried to see where SaveConfig() SaveConfig() is called in the Main_Thread (Worker_0) every time, anything in the assp configuration was changed. And under normal cirumstances, after that, all workers are told to check there configuration (and reload) in relation to the new one (lists, files,

Re: [Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-10-25 Thread K Post
We are lucky to have a new (to us) faster server donated since this original May posting on the "unable to transfer connection to any worker" error. However, with the new box with Windows 2019 installation, fully patched, MySQL latest community, and Strawberry perl 5.32 it's still happening in

[Assp-test] Main_Thread is unable to transfer connection to any worker - try again

2021-05-17 Thread K Post
I'm desperate for help. It seems that ASSP has thread problems frequently when it reloads the config. I see warnings that the Main_Thread is unable to transfer connection to any worker, often every 5 minutes for hours. May-17-21 20:40:35 Saving config May-17-21 20:40:35 Info: no configuration