Re: [BackupPC-users] Call timed out: server did not respond after 20000 ms

2010-12-21 Thread Gerald Brandt
Hi, I just got one of those as well. It looks like it may be a recursive link in the file system, though I'm not 100% sure. It may also be heavily nested directories. Gerald - Original Message - From: Jln backuppc-fo...@backupcentral.com To: backuppc-users@lists.sourceforge.net

Re: [BackupPC-users] Call timed out: server did not respond after 20000 ms

2010-12-21 Thread Pedro M. S. Oliveira
sorry wrote 10s but its 20 On Dec 22, 2010 12:39 AM, Pedro M. S. Oliveira pmsolive...@gmail.com wrote: i has this problem sometime ago it was due to the av on the windows server. it took just to much time to scan large files and smb client has a fixed timeout of 10secs. if u want to change it

Re: [BackupPC-users] Call Timed Out

2009-08-05 Thread Chris Baker
This problem doesn't necessarily mean open files. It could simply mean that it is having trouble reading a directory listing. I get this error quite a bit on some two older laptops. And it's almost always on the same directory. Rsync did not solve the problem either. It ended up abandoning

Re: [BackupPC-users] Call Timed Out

2009-08-05 Thread Les Mikesell
Tim Hall wrote: I'm using xfer method SMB to backup a server the whole job fails with this error Call timed out: server did not respond after 2 milliseconds opening remote file This is probably a symptom of on-access virus scanning. -- Les Mikesell lesmikes...@gmail.com

Re: [BackupPC-users] Call timed out: server did not respond after 20000, milliseconds

2007-05-21 Thread Craig Barratt
Regis writes: Backup stop with the message: Error reading file \Local Settings\Temp\Cover picture.tiff : Call timed out: server did not respond after 2 milliseconds If you look at the mail lists you will see that this error is typically due to anti-virus software running on the client

Re: [BackupPC-users] Call timed out: server did not respond after 20000, milliseconds

2007-05-21 Thread Regis Gras
Craig Barratt wrote: Regis writes: Backup stop with the message: Error reading file \Local Settings\Temp\Cover picture.tiff : Call timed out: server did not respond after 2 milliseconds If you look at the mail lists you will see that this error is typically due to anti-virus

Re: [BackupPC-users] Call timed out: server did not respond after 20000 milliseconds

2007-05-16 Thread Les Stott
Regis Gras wrote: I have still problems with backuppc-3.0.0. Backup stop with the message Error reading file \Local Settings\Temp\Cover picture.tiff : Call timed out: server did not respond after 2 milliseconds I am using samba-client-3.0.10-1.4E.11 for smbclient