Re: [Bacula-users] Tapes(Volumes) put into ERROR status

2007-11-08 Thread Arno Lehmann
Hi, 08.11.2007 15:17,, Win Htin wrote:: Hi folks, Just as I thought I have fixed my problems, I am again stumped with Volumes being put into Error with /*Error: Unable to position to end of data on device*/ messages. As previously mentioned in my other post, all the tapes were erased

[Bacula-users] Tapes(Volumes) put into ERROR status

2007-11-08 Thread Win Htin
Hi folks, Just as I thought I have fixed my problems, I am again stumped with Volumes being put into Error with *Error: Unable to position to end of data on device* messages. As previously mentioned in my other post, all the tapes were erased once over to make sure everything starts cleanly.

Re: [Bacula-users] Tapes(Volumes) put into ERROR status

2007-11-08 Thread Win Htin
Hi Arno, Added Two EOF = Yes and re-ran the btape test and the problem disappeared. Thanks again!! Win Hi, 08.11.2007 15:17,, Win Htin wrote:: Hi folks, Just as I thought I have fixed my problems, I am again stumped with Volumes being put into Error with /*Error: Unable to