Re: [Bacula-users] upgrade bacula 7 to 9 error

2021-10-21 Thread Phil Stracchino
On 10/21/21 7:00 AM, Agiofws Holylight wrote:
> 
> okay I sold itI ran the update mysqltables script with out the dpkg
> option i rav it as alinux binary and it updated the table version and
> now director works thank you


OK, you should be all set then.


-- 
  Phil Stracchino
  Babylon Communications
  ph...@caerllewys.net
  p...@co.ordinate.org
  Landline: +1.603.293.8485
  Mobile:   +1.603.998.6958


___
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users


[Bacula-users] Lookup of symbol "BaculaSDdriver"

2021-10-21 Thread SO Giuseppe - COMAE via Bacula-users
Hello, fellowes 

I am using Bacula 11.0.5 on Debian 10. After installation, including 
bacula-aligned package, everything is running well! 
After procedures to install ZFS and implement Optimized Volumes ( [ 
https://www.bacula.lat/block-level-deduplication-with-aligned-volumes-tutorial-bacula-7-9-9-0-and-above/?lang=en
 | 
https://www.bacula.lat/block-level-deduplication-with-aligned-volumes-tutorial-bacula-7-9-9-0-and-above/?lang=en
 ] ) an error rises when I start a job: 
bacula-sd JobId 384: Error: [SE0003] Lookup of symbol "BaculaSDdriver" in 
driver FileStorage for device 
/opt/bacula/plugins/bacula-sd-aligned-driver-11.0.5.so failed: 
ERR=/opt/bacula/plugins/bacula-sd-aligned-driver-11.0.5.so: undefined symbol: 
BaculaSDdriver
bacula-sd JobId 384: Warning: 
 Device "FileStorage" requested by DIR could not be opened or does not 
exist. 

Please, see attached the setup files. I still using Bacula for tests and it is 
not in production yet. 

I would like some help to solve this issue. I don't know if it is possible to 
use ZFS drive as a "Device Type = File" or I must to setup as "Device Type = 
Aligned" (look into bacula-sd.conf). 

Best regards. 

GIUSEPPE VALITUTTI NETTO 
Brasília/DF - Brasil 


--

[PT] Texto confidencial para uso exclusivo do destinat�rio. N�o o divulgue e 
apague-o imediatamente se o recebeu por engano.

[EN] This is a confidential text to be exclusively used by the recipient. Do 
not disclose it to anybody and delete it immediately if you received it by 
mistake.

[ES] Texto confidencial para uso exclusivo del destinatario. Si usted lo 
recibi� por error no lo divulgue y excl�yalo inmediatamente.




bacula-fd.conf
Description: Binary data


bacula-sd.conf
Description: Binary data


bconsole.conf
Description: Binary data


bacula-dir.conf
Description: Binary data
___
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users


Re: [Bacula-users] Slow transfer rate - MS Win 2019

2021-10-21 Thread Josh Fisher

On 10/16/21 17:37, Andras Horvai wrote:

Dear List,

Recently I faced to the following problem what I cannot solve:

I would like to backup a file server. It is a physical machine with 
Windows 2019 operating system.
This bacula sd is on the same vlan as this server (sd and dir is on 
the same server).

The issue is that we have very very low transfer rate.
The windows file server and bacula has 1 Gb/s interface, and despite 
this we have:
9452.2 KB/s rate which is about 74 Mb/s transfer rate. We are using 
9.4.4 as director and sd.

The file daemon version is:
9.4.4 (28May19) Microsoft Standard Edition (build 9200), 
64-bit,Cross-compile,Win64
I tried to set up the "Maximum Network Buffer Size = 32768" on fd and 
sd but did not help.



Both compression and encryption of data occur on the client. Try a job 
with no compression and no encryption. It is possible that the 
compression and/or encryption is slowing the Windows machine.


If you are writing to tape, then make sure that data spooling is 
enabled. Otherwise, if the data rate from the Windows server isn't fast 
enough, then the tape drive will be constantly rewinding to position its 
read/write head. Tape drives require a certain data rate to prevent 
this, and spooling will fix it.


If the storage device for the backup volumes is not directly attached to 
the server that bacula sd runs on and is on the same physical lan as sd 
and client, then data spooling should be enabled to reduce network 
contention..





If you have any ideas pls. share with me.

Thanks,

Andras


___
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users___
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users


Re: [Bacula-users] upgrade bacula 7 to 9 error

2021-10-21 Thread Agiofws Holylight
okay I sold it I ran the update mysqltables script with out the dpkg option
i rav it as alinux binary and it updated the table version and now director
works thank you


On Thu, 21 Oct 2021 at 13:31, Agiofws Holylight  wrote:

> apt-cache policy bacula
> bacula:
>   Installed: 9.4.2-2+deb10u1
>   Candidate: 9.4.2-2+deb10u1
>
> i think i had version 7
>
> systemctl status bacula-director
> ● bacula-director.service - Bacula Director Daemon service
>Loaded: loaded (/lib/systemd/system/bacula-director.service; enabled;
> vendor preset: enabled)
>Active: inactive (dead) (Result: exit-code) since Tue 2021-10-19
> 14:42:23 EEST; 1 day 21h ago
>  Docs: man:bacula-dir(8)
>   Process: 5488 ExecStartPre=/usr/sbin/bacula-dir -t -c $CONFIG
> (code=exited, status=1/FAILURE)
>
> Oct 19 14:42:23 law1 systemd[1]: bacula-director.service: Service
> RestartSec=1min expired, schedulin
> Oct 19 14:42:23 law1 systemd[1]: bacula-director.service: Scheduled
> restart job, restart counter is
> Oct 19 14:42:23 law1 systemd[1]: Stopped Bacula Director Daemon service.
>
> journalctl -xe
>
> http://codepad.org/su613hum
>
> - The job identifier is 2237.
> Oct 21 12:24:02 law1 bacula-dir[30956]: bacula-dir: dird.c:1229-0 Could
> not open Catalog "MyCatalog", database "bacula".
> Oct 21 12:24:02 law1 bacula-dir[30956]: bacula-dir: dird.c:1234-0 Version
> error for database "bacula". Wanted 16, got 15
>
>
>
>
>
>
>
>
>
>
>
>
>
> *SHOW DATABASES-> ;++| Database
> |++| bacula || information_schema || mysql
>  || performance_schema |++4 rows in set
> (0.011 sec)*
>
>
>
>
>
>
>
>
> *MariaDB [bacula]> select * from Version-> ;+---+| VersionId
> |+---+|15 |+---+1 row in set (0.000 sec)*
>
>
>
>

-- 
Χ.Μασούρας
___
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users


[Bacula-users] upgrade bacula 7 to 9 error

2021-10-21 Thread Agiofws Holylight
apt-cache policy bacula
bacula:
  Installed: 9.4.2-2+deb10u1
  Candidate: 9.4.2-2+deb10u1

i think i had version 7

systemctl status bacula-director
● bacula-director.service - Bacula Director Daemon service
   Loaded: loaded (/lib/systemd/system/bacula-director.service; enabled;
vendor preset: enabled)
   Active: inactive (dead) (Result: exit-code) since Tue 2021-10-19
14:42:23 EEST; 1 day 21h ago
 Docs: man:bacula-dir(8)
  Process: 5488 ExecStartPre=/usr/sbin/bacula-dir -t -c $CONFIG
(code=exited, status=1/FAILURE)

Oct 19 14:42:23 law1 systemd[1]: bacula-director.service: Service
RestartSec=1min expired, schedulin
Oct 19 14:42:23 law1 systemd[1]: bacula-director.service: Scheduled restart
job, restart counter is
Oct 19 14:42:23 law1 systemd[1]: Stopped Bacula Director Daemon service.

journalctl -xe

http://codepad.org/su613hum

- The job identifier is 2237.
Oct 21 12:24:02 law1 bacula-dir[30956]: bacula-dir: dird.c:1229-0 Could not
open Catalog "MyCatalog", database "bacula".
Oct 21 12:24:02 law1 bacula-dir[30956]: bacula-dir: dird.c:1234-0 Version
error for database "bacula". Wanted 16, got 15













*SHOW DATABASES-> ;++| Database
|++| bacula || information_schema || mysql
 || performance_schema |++4 rows in set
(0.011 sec)*








*MariaDB [bacula]> select * from Version-> ;+---+| VersionId
|+---+|15 |+---+1 row in set (0.000 sec)*