[Bacula-users] SD crashing when cancelling a job?

2005-12-20 Thread Wolfgang Denk
info available. #0 0x in ?? () No symbol table info available. #0 0x in ?? () No symbol table info available. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL

Re: [Bacula-users] Restore Issue with 1.36

2005-12-28 Thread Wolfgang Denk
is actually stored on your backup media? (What was the FD/SD Bytes Written message when you performed the backup? What does list volumes etc. give?) Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80

Re: [Bacula-users] Bacula 1.38.3 BETA mtx-changer script question

2005-12-29 Thread Wolfgang Denk
-1 [Note: both patches are mutually exclusive.] Hope this helps. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Those who will be able to conquer software

[Bacula-users] SD crashing when AutomaticMount is set?

2006-01-02 Thread Wolfgang Denk
08783000-087a4000 rw-p 08783000 00:00 0 [heap] b7f95000-b7f96000 rw-p b7f95000 00:00 0 b7fb2000-b7fbb000 rw-p b7fb2000 00:00 0 bfea5000-bfebb000 rw-p bfea5000 00:00 0 [stack] Aborted (core dumped) Any ideas what might go wrong? Best regards, Wolfgang Denk -- Software

Re: [Bacula-users] SD crashing when AutomaticMount is set?

2006-01-03 Thread Wolfgang Denk
to look for? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Is a computer language with goto's totally Wirth-less

Re: [Bacula-users] SD crashing when AutomaticMount is set?

2006-01-03 Thread Wolfgang Denk
()? DEVICE::rewind()? Let's see... Right. A 'mt -f ... rewind' hangs, too. so this is in fact a kernel (driver) problem, and not bacula's fault. Thanks. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142

Re: [Bacula-users] archive

2006-01-04 Thread Wolfgang Denk
), refers to the Maximum Volumes and Maximum Volume jobs directives. Yes, but please note the spelling. The last letter is a 'm', not a 'n'. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email

Re: [Bacula-users] Experience summaries

2006-01-04 Thread Wolfgang Denk
possible at all? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Conceptual integrity in turn dictates that the design must proceed from one mind, or from

Re: [Bacula-users] Installing on Fedora Core 4 with Gnome

2006-01-17 Thread Wolfgang Denk
-host=XXX - make That's all. OM, on second thought I think the critical RPM that is needed must be gnome-libs-devel, because this imports a lot of vital header files. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142

Re: [Bacula-users] different questions and feature requests...

2006-01-19 Thread Wolfgang Denk
for cleaning tape with a special LED, also manufacurer tells you only to use cleaning tape when asked for it Or (some) autoloaders can be configured to run cleaning cycles automagically when they need it. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime

Re: [Bacula-users] Having a job use volumes from 2 autochangers

2006-01-26 Thread Wolfgang Denk
backaups in a single magazine which I replace each Monday morning - works fine for me. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Karl's version of Parkinson's

Re: [Bacula-users] running out of space question about adding 2nd hdd

2006-02-03 Thread Wolfgang Denk
In message [EMAIL PROTECTED] you wrote: Why not add a large enough hd, move ALL the data to it and then softlink the entire directory to the new drive. Why not using LVM so this problem just does not happen at all? Best regards, Wolfgang Denk -- Software Engineering: Embedded

Re: [Bacula-users] Simulate/Test Scheduler?

2006-02-09 Thread Wolfgang Denk
in place with all relevant data is IMHO a very, very serious error. For me it's close to being a killing point :-( Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Why

Re: [Bacula-users] Skip a day in Date-time-specification ?

2006-02-09 Thread Wolfgang Denk
. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Life, loathe it or ignore it, you can't like it. - Marvin the paranoid android

Re: [Bacula-users] Spooling can slow Bacula

2006-02-20 Thread Wolfgang Denk
it tuirned on for differential and incremental ones. I didn't find out yet how to do this. Any pointers? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] The speed

Re: [Bacula-users] Spooling can slow Bacula

2006-02-21 Thread Wolfgang Denk
will a restore be much faster compared to a tape where all A data are consecutive, followed by all B and then all C data? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL

Re: [Bacula-users] Spooling can slow Bacula

2006-02-22 Thread Wolfgang Denk
because data transfer from the FDs is simultaneous. Thanks for the confirmation! Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Madness has no purpose. Or reason

Re: [Bacula-users] tape labeling error

2006-03-02 Thread Wolfgang Denk
. Everything is fine. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] I will also, for an appropriate fee, certify that your keyboard is object-oriented

[Bacula-users] Strange SCSI problems

2006-03-13 Thread Wolfgang Denk
at bacula, or at least at the bacula tape access pattern. Has anybody else ever seen something like this? Any ideas what to look for? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email

Re: [Bacula-users] Strange SCSI problems

2006-03-13 Thread Wolfgang Denk
and is not available and does not compile for current kernel versions. Lesson learned.] Thanks anyway. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] [Doctors

[Bacula-users] (no subject)

2006-03-14 Thread Wolfgang Denk
DDS-3 Ummm... bacula can access the media just fine for backup, so why does it complain on restore? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] 365 Days

[Bacula-users] Could not hard link .. errors?

2006-03-15 Thread Wolfgang Denk
=No such file or directory ... I have no hardlink related settings in any of my config files, i. e. I expect that the default setting of hardlinks=yes takes effect. What might have caused the above problem, and how can it be avoided? Best regards, Wolfgang Denk -- Software Engineering

Re: [Bacula-users] Too early End Of Medium

2006-03-17 Thread Wolfgang Denk
; mt -f /dev/nst0 stoptions 0 after mounting a tape; if this is an autoloader device, add these commands to your mtx-changer script after loading a tape. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49

Re: [Bacula-users] tape writing error in bacula

2006-03-17 Thread Wolfgang Denk
message Strange SCSI problems of March 13 on this list. Check your system logs if you see any error messages there; look especially for messages like these: sense key Unit Attention, Additional sense: Power on, reset, or bus device reset occurred. Best regards, Wolfgang Denk -- Software

Re: [Bacula-users] Potential concerns about Bacula

2006-03-22 Thread Wolfgang Denk
relative or absolute path names. I've been told at that time that one must not use --one-file-system and --listed-incremental in one call, which makes this unusable for any bigger systems with mounted partitions. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime

Re: [Bacula-users] Disabling Client

2006-03-22 Thread Wolfgang Denk
-hostname.conf) which we include in bacula-dir.conf; with such a setup it is easy judt to comment out the include statement. And it makes the config file much more readable... Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10

[Bacula-users] End-of-Volume errors

2006-03-23 Thread Wolfgang Denk
good, or must I fear to lose data when trying to restore from this archive? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Knowledge, sir, should be free to all

Re: [Bacula-users] End-of-Volume errors

2006-03-23 Thread Wolfgang Denk
during my full backups, so it's easily reproducible for me. So let's remember that fact, too. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Open the pod bay doors

[Bacula-users] Problems with 1.38.6 under Fedora Core 5 ?

2006-04-04 Thread Wolfgang Denk
run my backups manually, but the next scheduled run will fail with the same errors. Any ideas? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] The universe

Re: [Bacula-users] Problems with 1.38.6 under Fedora Core 5 ?

2006-04-05 Thread Wolfgang Denk
idle? Why cannot we close and reopen when needed? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Do not underestimate the value of print statements for debugging

Re: [Bacula-users] Preventing mysql server has gone away problem.

2006-04-06 Thread Wolfgang Denk
and then type a list volumes or any other command accessing the database in the console. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] If I had to live my life again, I'd

Re: [Bacula-users] When is a tape Full?

2006-04-09 Thread Wolfgang Denk
data: 6st0: Current: sense key: Unit Attention Additional sense: Power on, reset, or bus device reset occurred ??? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL

Re: [Bacula-users] When is a tape Full?

2006-04-09 Thread Wolfgang Denk
: Wolfgang Denk [EMAIL PROTECTED] Date: Mon, 13 Mar 2006 13:00:57 +0100 and Subject: [Bacula-users] tape writing error in bacula From: david robert [EMAIL PROTECTED] Date: Fri, 17 Mar 2006 09:30:52 + (GMT) No, I didn't find any of these messages. However, at the time

Re: [Bacula-users] Bacula marking tapes Full with only a few GB written

2006-04-12 Thread Wolfgang Denk
issue in the SCSI tape driver layer. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Plan to throw one away. You will anyway. - Fred

Re: [Bacula-users] Bacula marking tapes Full with only a few GB written

2006-04-12 Thread Wolfgang Denk
In message [EMAIL PROTECTED] you wrote: I am more and more convinced that this is a subtel timing issue in the SCSI tape driver layer. Do you think it could be an overrun situation? Overrun of what? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime

Re: [Bacula-users] Bacula marking tapes Full with only a few GB written

2006-04-16 Thread Wolfgang Denk
different systems with different cables, terminators, drives, etc. And only with bacula, when writing without spooling. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED

Re: [Bacula-users] Bacula marking tapes Full with only a few GB written

2006-04-16 Thread Wolfgang Denk
), or it overran the SCSI command queue. I will try to run some tests... Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] ...this does not mean that some of us should

Re: [Bacula-users] Incremental job changes to Full (Storage does not change)

2006-04-25 Thread Wolfgang Denk
regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] I can call spirits from the vasty deep. Why so can I, or so can any man; but will they come when you do call for them

Re: [Bacula-users] Incremental job changes to Full (Storage doesnot change)

2006-04-25 Thread Wolfgang Denk
, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] What's the sound a name makes when it's dropped? --- Using Tomcat but need to do more

Re: [Bacula-users] tape drive recommendation

2006-04-29 Thread Wolfgang Denk
. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Today is the yesterday you worried about tomorrow. --- Using

Re: [Bacula-users] Re: How much available space on the tape?

2006-05-21 Thread Wolfgang Denk
not be able to put this information to use. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] What the scientists have in their briefcases is terrifying. - Nikita

Re: [Bacula-users] Problem with the list???

2006-05-24 Thread Wolfgang Denk
. The SF people hope that the new version might fix all the mailing list problems they have, and had - again and again. We've seen lng delays on several mailing lists. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142

[Bacula-users] Interesting failure mode

2006-07-03 Thread Wolfgang Denk
in the future? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] I express preference for a chronological sequence of events which precludes a violence. - Terry

Re: [Bacula-users] Interesting failure mode

2006-07-04 Thread Wolfgang Denk
to Munich this summer? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] If there was anything that depressed him more than his own cynicism, it was that quite often it still

Re: [Bacula-users] Interesting failure mode

2006-07-04 Thread Wolfgang Denk
in the same direcotry where the volumes are stored result in the expected no space left errors. May I re-ask: BTW: are you still planning for a trip to Munich this summer? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49

Re: [Bacula-users] Last chance before I [EMAIL PROTECTED] tapedrivethrough the window ...

2006-07-16 Thread Wolfgang Denk
options to the given value, 0. So stsetoptions will leave any options set to 1 unchanged, while stoptions will reset thtese to zero. Small difference in typing, big difference in effect. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux

Re: [Bacula-users] Advantages with spooling.

2006-07-27 Thread Wolfgang Denk
data while the first one is blocked while spooled data is written to tape. The number of jobs you need obviously depends on how quickly you can collect and spool data, and on the speed of your tape drive. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems

Re: [Bacula-users] Advantages with spooling.

2006-07-27 Thread Wolfgang Denk
the shoe shining. It's not only the network speed which plays a role, but also the speed of the bacula client collecting the data. Especially when running incremental backups on large partitions with little changes, data can trickle pretty slowly. Best regards, Wolfgang Denk -- Software

Re: [Bacula-users] ERR=Device or resource busy

2006-08-18 Thread Wolfgang Denk
regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] When the ax entered the forest, the trees said, The handle is one of us! -- Turkish

Re: [Bacula-users] setting tape options before each access

2007-01-01 Thread Wolfgang Denk
regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] ...all the good computer designs are bootlegged; the formally planned products, if they are built at all, are dogs

[Bacula-users] Bacula plugins for munin?

2007-01-03 Thread Wolfgang Denk
Hi, has anybody any plugins available for monitoring bacula status under munin? Thanks in advance. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] For every

Re: [Bacula-users] speeding up bacula?

2007-01-07 Thread Wolfgang Denk
, even using the same disk sizes, raid configuration and RAID controller. And I see the same thing, and I measured that we spend most time in iowait. See my previous posting. Also, I can confirm that other setups (no RAID, no 3ware controllers) behave differently. Best regards, Wolfgang Denk

Re: [Bacula-users] Bacula development voting

2007-01-15 Thread Wolfgang Denk
Priority Project Number = 11 23 36 4 25 5 18 Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80

Re: [Bacula-users] Concurrent jobs

2007-01-24 Thread Wolfgang Denk
In message [EMAIL PROTECTED] you wrote: Implementing a disk to disk to tape setup would be the other choice, now that 2.0 is out. Is there some example for such a configuration available somewhere? Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems

Re: [Bacula-users] Concurrent jobs

2007-01-24 Thread Wolfgang Denk
regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Doubt is a pain too lonely to know that faith is his twin brother. - Kahlil Gibran

Re: [Bacula-users] What to do when tape full?

2007-02-27 Thread Wolfgang Denk
=... Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, HRB 165235 Munich, CEO: Wolfgang Denk Office: Kirchenstr. 5, D-82194 Groebenzell,Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Put your Nose to the Grindstone

Re: [Bacula-users] bacula-users email list

2007-04-16 Thread Wolfgang Denk
are not web browsers. verified belief is that newbies presented with a choice of forum versus e-mail list will choose the forum. You are probably right. That's because they don't know it better. Most experts decide the other way. Best regards, Wolfgang Denk -- DENX Software Engineering

[Bacula-users] backup on 64 bit machine, restore on 32 bit machine = chaos?

2007-05-30 Thread Wolfgang Denk
.) about new features in 1.40.0, so can I assume that this problem has been fixed for the 2.x releases? Thanks in advance. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone

Re: [Bacula-users] backup on 64 bit machine, restore on 32 bit machine = chaos?

2007-05-31 Thread Wolfgang Denk
sure that you built your FD running on the 64 bit machine in 64bit mode? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80

Re: [Bacula-users] Autochanger questions

2007-09-02 Thread Wolfgang Denk
} (This assumes you use the pool names FULL, DIFF and INCR, resp.) Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL

Re: [Bacula-users] Critical Bacula Bug

2007-09-09 Thread Wolfgang Denk
the problem. Is my interpretation correct that only the SD is affected, i. e. there is no need to touch the DIR and FD? So most clients which just run the FD need no patching? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich

Re: [Bacula-users] Backing up to tape -- how many catalog backups to keep?

2007-09-22 Thread Wolfgang Denk
frequently find myself in the position that I need to restore some file which is not listed any more in the catalog. I am usually pretty happy then to be able to restore a N months old copy so I need only two steps. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang

Re: [Bacula-users] Insert bug?

2007-10-08 Thread Wolfgang Denk
Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: [EMAIL PROTECTED] Horses just naturally have mohawk haircuts

Re: [Bacula-users] iSCSI-Tape problems

2007-10-28 Thread Wolfgang Denk
the difference in how tar writes to tape versus how btape writes to tape. This is a misinterpretation. The physical *tape* block size or record size is a multiple of the 512 byte block size, as determined by the '-b' resp. '--blocking-factor' option. Best regards, Wolfgang Denk -- DENX Software

Re: [Bacula-users] Barcode Labels

2008-02-14 Thread Wolfgang Denk
to reference slot 4. Catalog record for Volume K-Q-9 updated to reference slot 5. Catalog record for Volume K-S-0 updated to reference slot 6. Catalog record for Volume K-S-1 updated to reference slot 7. Hope this helps... Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD

[Bacula-users] Enable/disable spooling when starting jobs with run ?

2008-11-02 Thread Wolfgang Denk
: disable it) in the Run statements in the schedule. However, how can I do the same when running a job manually using the run command on the console? It seems there is no option to enable or disable spooling then? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD

Re: [Bacula-users] Time for change

2008-12-09 Thread Wolfgang Denk
(that does not perform other services which would utilize the CPU) s/w RAID gives much better performance - at least in the usage szenarios we see (which means serving a *big* number of relatively small files). Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang

[Bacula-users] List last 20 Full Backups for a Client broken?

2009-01-03 Thread Wolfgang Denk
? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de Prediction is very difficult, especially of the future

[Bacula-users] Enable/disable spooling when starting jobs with run ?

2009-01-03 Thread Wolfgang Denk
: disable it) in the Run statements in the schedule. However, how can I do the same when running a job manually using the run command on the console? It seems there is no option to enable or disable spooling then? Or am I missing something? Best regards, Wolfgang Denk -- DENX Software

Re: [Bacula-users] Program killed by Bacula watchdog (timeout) errors

2009-01-11 Thread Wolfgang Denk
-changer completes normally, but I will test this. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de Vulcans

Re: [Bacula-users] Anyway to do multi-core compression?

2009-01-22 Thread Wolfgang Denk
that value). getconf _NPROCESSORS_ONLN (respective the equivalent C code) might be a good start. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax

[Bacula-users] Feature request: Enable/disable spooling when using run

2009-02-08 Thread Wolfgang Denk
Item 1: Enable/disable spooling when starting jobs with run Date: Mon Feb 9 00:41:01 CET 2009 Origin: Wolfgang Denk w...@denx.de Status: What: I would like to be able to override the spooling settings of a job when manually starting it using run. Why:Normally we

Re: [Bacula-users] Feature request: Enable/disable spooling when using run

2009-02-09 Thread Wolfgang Denk
; it thus is part in the most recent 2.5 beta releases and will be part of the upcoming 3.0 release. Ah, cool. Thanks for the information. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194

Re: [Bacula-users] Spanish Bacula email list

2009-04-15 Thread Wolfgang Denk
, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de A person with one watch knows what time it is; a person

Re: [Bacula-users] Label Barcodes delete data?

2009-09-21 Thread Wolfgang Denk
-001 ABV102 I-002 ABV103 I-003 ABV104 I-004 ABV105 I-005 ABV106 I-006 ... Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989

Re: [Bacula-users] New autochanger adds L3 after tape barcode

2009-10-19 Thread Wolfgang Denk
? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de READ THIS BEFORE OPENING PACKAGE: According to Certain

Re: [Bacula-users] Using Bittorrent as Backup Technology

2010-02-07 Thread Wolfgang Denk
efficient. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de There is a time in the tides of men, Which

Re: [Bacula-users] Problem with install on Linux.

2010-05-27 Thread Wolfgang Denk
-password=bacula23 \ --with-mon-fd-password=bacula23 \ --with-mon-sd-password=bacula23 \ --with-db-name=bacula \ --with-db-user=bacula \ You want to use MySQL, so you should add (at least) --with-mysql Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev

Re: [Bacula-users] wanted: DLT barcode labels

2010-05-31 Thread Wolfgang Denk
autoloaders are extremely picky and require a special high-reflective material (all my attempts to use self-printed labels failed so far), but in this case this looks not so difficult. You know GNU Barcode ? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev

Re: [Bacula-users] change tape status while backups are running

2010-06-02 Thread Wolfgang Denk
hand, I don't want to job to stall until Monday when the tape finally fills up. If it was possible to signal a tape full condition, I could enforce the insertion of a new magazine. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235

Re: [Bacula-users] Bacula stalls after 2.5 TB

2010-12-01 Thread Wolfgang Denk
/firewall/mysql/archive/sdw_netflow/netflow_20100430.tar on that system show? Is there any chance that this is a sparse file with (big) holes (eventually even unintentionally, like after some error in a RAID)? Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk

Re: [Bacula-users] Bacula stalls after 2.5 TB

2010-12-03 Thread Wolfgang Denk
that this might be a sparse file (eventually unintentionally, like after disk errors) and you consume the time compressing a zillion of null bytes or similar. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194

Re: [Bacula-users] Cancel Multiple Jobs

2011-06-14 Thread Wolfgang Denk
, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de Emotions are alien to me. I'm a scientist. -- Spock, This Side

Re: [Bacula-users] st: from_buffer offset overflow. - I/O Error

2011-06-15 Thread Wolfgang Denk
will write in 63 KiB blocks, so you should never need that much. What does your /etc/stinit.def look like? [Or where else do you configure your tape driver to use such buffers?] Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich

Re: [Bacula-users] Linux: backup and restore of file capabilities ?

2012-01-02 Thread Wolfgang Denk
-common-5.0.3-13.fc16.x86_64 bacula-storage-mysql-5.0.3-13.fc16.x86_64 Anything ales I could look for? Thanks in advance. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell

Re: [Bacula-users] Linux: backup and restore of file capabilities ?

2012-01-02 Thread Wolfgang Denk
that, but I could not see any. The log file is available here: ftp://ftp.denx.de/pub/tmp/log.gz Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10

Re: [Bacula-users] Linux: backup and restore of file capabilities ?

2012-01-03 Thread Wolfgang Denk
to solve that. I understand the problem is located, and no further testing on my side is needed? Thanks. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989

[Bacula-users] Problems with Jumbo packets?

2012-01-06 Thread Wolfgang Denk
regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de This restaurant was advertising breakfast any time. So I

Re: [Bacula-users] Problems with Jumbo packets?

2012-01-06 Thread Wolfgang Denk
on the impacted hosts Yes, I do have some of these, too. But these are easy to spot as they don't accept larger MTU's: # ifconfig eth0 mtu 9000 SIOCSIFMTU: Invalid argument # ifconfig eth0 mtu 7200 # Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel

Re: [Bacula-users] Problems with Jumbo packets?

2012-01-06 Thread Wolfgang Denk
Dear Frank Sweetser, In message 4f0722a4.5090...@wpi.edu you wrote: Are all of the machines on the same subnet? If not, you'll also have to check the MTU on all of your local router interfaces. Yes, they are all in the same net, and all on the same switch. Best regards, Wolfgang Denk

Re: [Bacula-users] Problems with Jumbo packets?

2012-01-06 Thread Wolfgang Denk
the advice. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de An expert is a person who avoids the small

[Bacula-users] parallelizing jobs

2012-04-05 Thread Wolfgang Denk
is something that involves the DIR and the SD only, so it should not block the client from starting the next backup job. Seems I'm missing something here. Any ideas are highly welcome. Thanks in advance. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev

Re: [Bacula-users] parallelizing jobs

2012-04-05 Thread Wolfgang Denk
Dear John Drescher, In message CAEhu1-7L0Q=jNQqBf_d_5VPaRHxsNKN-Szh7Zh_h=nk8op-...@mail.gmail.com you wrote: Do you have any restrictions on how many jobs go per volume? No. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235

Re: [Bacula-users] parallelizing jobs

2012-04-05 Thread Wolfgang Denk
that? All these jobs use the same pool, so both jobs and thus both clients will use the same volume. There are other jobs running in parallel, too (but not as many as to run into the max job limit). Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev

Re: [Bacula-users] parallelizing jobs

2012-04-05 Thread Wolfgang Denk
and DIR are still processing this job. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de An open mind has

[Bacula-users] Tweak SCSI negotiation settings

2012-10-18 Thread Wolfgang Denk
a limitation. [Yes, I am aware that the Adaptec 2940 is not exactly new. But I should get more than 8.8 MB/s out of it, should I not?] Any help welcome. Thanks in advance. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office

Re: [Bacula-users] Tweak SCSI negotiation settings

2012-10-18 Thread Wolfgang Denk
my suspicion that I should start by replacing the SCSI adapter. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w

Re: [Bacula-users] Summary - Tweak SCSI negotiation settings

2012-10-21 Thread Wolfgang Denk
that this should be chosenin the 1024 ... 2048 KiB range. With this setup I get now sustained data rates of 55...59 MiB/sec for uncompressible data, and data rates varying between 80...140 MiB/sec for compressible data. Thanks! Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk

[Bacula-users] Tape-to-tape copy job?

2012-11-05 Thread Wolfgang Denk
on the console command line? Any help welcome, thanks in advance. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w

Re: [Bacula-users] wanted on DEVICE-0, is in use by device DEVICE-1

2012-11-09 Thread Wolfgang Denk
' # Spool Data to disk before writing to tape Spool Directory = /backup/spool Maximum Spool Size = 5120GB Maximum Job Spool Size = 5120GB } Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194

  1   2   >