scripts. These jobs terminated correctly using the
same GJ8634L5 LTO-5 tape, so I believe is not a problem with the tape.
Have you ever seen a similar prbolem?
Thanks in adavance for attention and sorry for my poor english.
Simone Martina
--
01010011 01011001 01010011
Skylogic a EutelSat Com
Hi at all,
I'm trying to monitor our old HP MSL6030 (rebranded Overland 6000)
tapelibrary. Due to these libraries are quite old, we cannot find the
Mib specs.
Can someone help us?
Thanks in advance.
Simone
--
01010011 01011001 01010011
Skylogic a EutelSat Company
--
---
AM: this server runs
bacula-dir, mysql and nothing else.
Where's my mistake? Could you suggest me some optimization.
Thanks in advance.
Simone Martina
--
01010011 01011001 01010011
Skylogic a EutelSat Company
--
This message contains confidential information and is intended only for the
indi
Hi at all,
since two weeks I got problem with my HP MSL4048, a two reader library
connected by SAS to my Centos 5 (32bit) Bacula server.
Randomly the s.o. is not able to see the library, but this one return no
error (on the web managemente): the only signs of problem could be seen
into dmesg output
> -- Messaggio originale ---
> Storage:"LTO4Driver" (From Job resource)
> [...]
> Rate: 6816.5 KB/s
Aren't you using a TAPE to store your backup?
IMHO, probably the speed is bottlenecked by the TAPE
trasmission rate.
Simone
-
Hi at all,
my boss give me a budget of 20.000$ to buy a new tape library for our
Bacula 5 server. I've tried to cross informations between MTX HCL
(http://mtx.opensource-sw.net/compatibility.php?sorttype=1&start=1&count=0)
and HP, our main supplier.
From HP I've selected these libraries:
http:
Hi at all,
someone of my colleagues tends to save non-work files (like large avi
file) in shared directory and so my bacula backup Job take a lot of time
due to save these unuseful rubbish... I would like to find full path of
something file name contaings avi or AVI, has bconsole a sort of comma
Thanks for your suggestions, I propose a query made with help of a
friend of mine:
SELECT CONCAT(Path.Path,Filename.Name) FROM Filename Inner Join File ON
Filename.FilenameId = File.FilenameId Inner Join Path ON File.PathId =
Path.PathId where (Filename.Name LIKE "%avi") OR (Filename.Name LIKE
Hi at all,
my Bacula 5 system is still running since the beginning of February and
now I've seen that the size of my mysql instance is grown to 30GB.
My scheduled backups are so divided:
- a full backup on Thursday, recycled every 4 weeks
- a month full backup on the last Thursday of the month, ne
On 06/18/2010 04:38 PM, John Drescher wrote:
> run dbcheck
> John
>
Thanks, I've just cleaned many orphaned entries, but I got just another
problem: the Log tables (in mysql) is quite 30GB! :O
dbcheck does not get a function to clear this data.
Should I purge them manually?
Simone
--
On 06/18/2010 05:41 PM, John Drescher wrote:
> You are talking about mysql binary logs?
> There is a command to purge these in mysql.
>
> John
>
>
Yes, I've found a radical solution with mysql: truncate Log
I would hope there were a inside Bacula way... doesn't matter, many
thanks for your hel
On 07/23/2010 06:45 PM, Jeremiah D. Jester wrote:
I have a volume that I am recycling back into the pool before the
volume expiration date. How do I simply wipe this tape or start the
write position to the beginning of the tape to overwrite the old data?
When I've to force recycling a tape,
Hi at all,
at the end of this year probably I will have to solve a trouble: my boss
would like to have an adjunctive bacula director (and sd, tape-reader
and so on) due to respect redundancy asset policy. Now, my Bacula
contacts every db server to remotely dump mysql tables to make a backup
of
Hi at all,
I got a trouble: a server of our server farm runs some perl scripts that
are bad influenced by Bacula backup.
Until our developers will return from holiday (damn), I need to limit
bacula speed.
Our servers are connected by 100Mbps ethernet network, should I tune
Maximum Network Buff
On 08/13/2010 05:59 PM, Alex Chekholko wrote:
> If you are running Linux, you probably want to use the tc command to
> throttle traffic to the bacula port.
>
> Search Google for "linux tc throttle". Something like this:
> http://www.cyberciti.biz/faq/linux-traffic-shaping-using-tc-to-control-htt
On 08/13/2010 05:59 PM, Alex Chekholko wrote:
> On Fri, 13 Aug 2010 17:00:21 +0200
> Simone Martina wrote:
>
>>Hi at all,
>> I got a trouble: a server of our server farm runs some perl scripts that
>> are bad influenced by Bacula backup.
>> Until our de
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Hi at all,
I've noticed that our backup system keeps much time to finish servers'
backup. Monitoring our 100Mbps net, by cacti, I see that backup speed
run at 1MBps, at least, meanwhile on another 1000Mbps we could have a
10MBps backup. This condition
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
On 09/16/2010 04:43 PM, John Drescher wrote:
> No. Bacula does not throttle bandwidth. Are you using spooling? Do you
> have millions of small files? Are the source disks highly fragmented?
> Are we talking about full backups because any other level wi
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Hi,
I'm trying to backup some folders from a server. I could list them from
bash with this command:
ls /ftpdir/linkstar/rncc??/burst/*.gz
But I wasn't able to write the right file set, I've tried in this way:
Include {
Options {
signature
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Hi at all,
this (sad) morning I've tried to append a job to a used volume (a tape):
despite I've tried to update status, job retention and so on, Bacula
marks that tape like purgeable and begin to write the new data on the
beginning of the tape.
When I
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Hi at all,
yesterday I've added a second LTO-4 ULTRIUM 1640 tape reader into my HP
MSL6030 SCSI tape library. I'm using Bacula 5.0.2 on Centos 5 x64.
I've updated my config in this way:
## bacula-sd.conf
Autochanger {
Name = "Autochanger"
Device =
Hi at all,
since some weeks I got a new SCSI controller due to use a second tape
reader into the HP MSL6030 (a Overland NEO 2000 clone) tape library.
After some initially troubles and a some telephonic shout with HP
support, now I'm able to use both internal reader (nst0 and nst1) and to
control th
On 02/25/2011 12:41 PM, Mathieu BALCERAK wrote:
> Host: x86_64-unknown-linux-gnu -- debian wheezy/sid
Have you installed all needed dev and header packages?
Simone
--
Free Software Download: Index, Sea
On 03/09/2011 02:28 PM, Bartłomiej Syryjczyk wrote:
> Hi,
> Is it possible to install storage daemon only from sources and in
> this case is the MySQL is needed?
> I've got director and catalog on different machine without connection to
> tabe library, and want to install SD on another host.
Goodevening,
I got a little problem: I have a bacula director on a server with two
NIC interfaces, each of one got a different subnet: 172.20.60.0/24 and
172.20.61.0/24 and I could only use a single LTO-4 tape reader.
Now, the problem is howto configure storage section in director
configuration fil
Good morning,
I've to buy a new tape library and I've discovered that HP dismisses on
July the well known MSL6030 (analog to Overland NEO 2000e).
Our seller want's to sell us a HP MSL4048, but mtx-changer web site is
offline and I could not see compatibility list:
http://mtx.opensource-sw.net/compa
suffix -- unchanged
... and so on until
make: *** [install] Error 2
I could complete my installation voiding install: section into
manpages's Makefile, but it is just a dirty workaround.
There is something wrong into my system or is it a little bug?
Regards,
Simone Ma
Il 14/06/2012 16:29, Gandalf Corvotempesta ha scritto:
> How can I verify the copy? Can I list the contents of my tapes?
Maybe you can use bscan to scan the tape, the tool returns a DB
resultset normally used to retrive tape content due to recover a pruned job.
Simone
--