Re: Temperature Controller goes off

2011-05-19 Thread Ira
At 06:29 PM 5/18/2011, you wrote: Could be the temperature sensor in the boiler, a cheap but difficult part to locate. Check the skinny black wire that runs from the back of the controller to the well in the brew boiler. The wire can crack in the heat and intermittently short out causing the

Re: Temperature Controller goes off

2011-05-19 Thread Fred
Hi Ira, Thank you for your quick response. I checked the black wire and actually it's cracked right in the border on the top of the boiler. How can I fixed that? Should I just pull the wire and tape it? I tried to pull the wire and feel some resistant. If I pull it out how can I reattached?

Re: Temperature Controller goes off

2011-05-19 Thread TWG
The sensor is located in the thermowell and the thermal compound probably has hardened. Wait for Ira's response but you should probably just tape with heat resistant electrical tape. On May 19, 9:36 am, Fred festr...@gmail.com wrote: Hi Ira, Thank you for your quick response. I checked the

Re: Temperature Controller goes off

2011-05-19 Thread Ira
At 06:36 AM 5/19/2011, you wrote: Thank you for your quick response. I checked the black wire and actually it's cracked right in the border on the top of the boiler. How can I fixed that? Should I just pull the wire and tape it? I tried to pull the wire and feel some resistant. If I pull it out

Re: Temperature Controller goes off

2011-05-19 Thread Fernando Estremadoyro
If replace it, Should I just have to pull the black wire from the thermowell? The crack is just in the border of the little hole, and it would be almost impossible to wrap the wire con tape. Sent from my BlackBerry® -Original Message- From: HERMAN badhabit...@yahoo.com Sender: