time to JUNK it.
On Sunday, September 5, 2021 at 1:12:39 PM UTC-7 Mike PDX wrote:
> Hi, my Brewtus III-R has has been a workhorse for the last 12
> years. There have been a few failures during that time period (PID,
> Pressure Stat, and Steam Pressure Gauge) but they really have been straight
Thanks for such a detailed answer Brian! I think my first step is to
replace the pressurestat since it's due (replaced the first one ~5 years
ago) and will see if that solves the problem before breaking out the
multimeter ;) Also, anyone have a source for the pressurestat pipe? Or
barring
Hey Mike,
The reason the steam boiler is effecting the ability of the brew boiler to
heat is because power to the brew boiler is routed through the
pressurestat. The pressurestat has 3 prongs, one is the common where the
power is fed in. One is normally closed which feeds power to the steam