On 10/2/23 03:00, Stuart Henderson wrote:
It doesn't directly help you, but the boot loader doesn't have any
NIC-specific code, it calls into EFI to make network connections.
That certainly does help clarify things.
the 1-line info for
the latest firmware for VP4650 says "CSM UEFI Network fix"
On 2023/10/02 18:24, Alexander Bluhm wrote:
> On Sun, Oct 01, 2023 at 06:25:41PM -0700, Ian R. wrote:
> > ?? The 'bsd' file it's looking for definitely does exist on my pxeboot
> > server, in the tftpd root dirirectory where it's supposed to be. I've
>
> It is supposed to be in an IP
On Sun, Oct 01, 2023 at 06:25:41PM -0700, Ian R. wrote:
> ?? The 'bsd' file it's looking for definitely does exist on my pxeboot
> server, in the tftpd root dirirectory where it's supposed to be. I've
It is supposed to be in an IP address subdirectory. At least that's
how my setup looks
On 2023/10/01 18:25, Ian R. wrote:
> My best guess is that OpenBSD's BOOTX64.EFI is lacking
> support for the 'igc' Intel I225-V 2.5Gbps NICs
It doesn't directly help you, but the boot loader doesn't have any
NIC-specific code, it calls into EFI to make network connections.
> Here are
> Synopsis: PXE install of OpenBSD 7.3 (amd64) fails on Protectli
VP4650 & VP2420, with 'igc' Intel I225-V 2.5Gbps NICs
> Category: Network
> Environment:
System : OpenBSD 7.3
Details : OpenBSD 7.3 (GENERIC.MP) #3: Tue Jul 25 08:20:26 MDT 2023
Architecture: OpenBSD.amd64