hi,
I config the Service parameter for MVA , using partial match 7 digit .
However when I dial the RD using 7 digit ,it never works.
seem like UCM only take Full match. I heard this is bug,
Any suggestion for the work around if still want to use partial match ?
d
On Sun, Mar 17, 2013 at 9:58
hi guys,
call to users vm works just fine but when transfering to a vm extension it
drops. pls what could be the problem??
___
For more information regarding industry leading CCIE Lab training, please visit
www.ipexpert.com
Are you a CCNP or CCIE and
a CCNP or CCIE and looking for a job? Check out
www.PlatinumPlacement.com
-- next part --
An HTML attachment was scrubbed...
URL: /archives/ccie_voice/attachments/20130325/54e5c4f5/attachment.html
You can have the rd with 7 digits only and without the 9 for pstn access -
use either application dial rules (match 7 digits, prefix 9) or a
translation pattern to modify the rd to match your existing local route
pattern.
I'm not sure if there's an MVA bug in this version of cucm, but its pretty
hi William,
Thanks for your reply.
I have now added the following for step (b) and added (c) ,(d),(e)
-start
-accept
-play prompt ( welcome prompt)
-menu( triggering contact , operator.wav)
-option 1:-
a) call redirect to 4001
b) If successful terminate
c) if busy goto queueloop
d)
Hi Folks,
dialplan-pattern 1 902312... extension-length 4...
when it comes to voice translation rule is it mandatory to remove above
command.
Thanks,
Ravi.
___
For more information regarding industry leading CCIE Lab training, please visit
hi justin,
the full match, always work.
Just when we do partial , it never , and always ask for RD number after we
dial the MVA.
I did exactly you suggest below.
-
A real world (for nanp) example of MVA partial match would be using e164
address
Since no one responded, I guess I'll be the geek for now.
The difference between using network-side clocking and user-side clocking
is similar to the DCE / DTE difference. PRI and E1 are implementations of
the ISDN protocol over T1 à a point-to-point, synchronous circuit. Synchronous
circuits
Really good explanation from Tony.
As an addendum to him, you can use show controllers command to verify
that the controller is set to clock source line, which, as Tony already
mentioned, is hidden being default.
On Tue, Mar 26, 2013 at 8:26 AM, Tony Zunt tony.z...@gmail.com wrote:
Since no