Re: [c-nsp] 6509 problem

2010-01-25 Thread James Greig
Hi Pete, Thanks for your response, I think you've confirmed our suspicions. We'll source another chassis:) James G -Original Message- From: Pete Templin [mailto:peteli...@templin.org] Sent: 24 January 2010 19:00 To: James Greig Cc: cisco-nsp@puck.nether.net Subject: Re: [c-nsp] 6509

Re: [c-nsp] 6509 problem

2010-01-24 Thread James Greig
' Cc: cisco-nsp@puck.nether.net Subject: Re: [c-nsp] 6509 problem Hi, Thanks for the response. I've pasted below the most prominent errors in the event log. Again, any ideas or anything to try are appreciated. 2/28 22:44:29.919 E [1]check_ether_packet [1/48]: newpak is NULL! 02/28 22:44

Re: [c-nsp] 6509 problem

2010-01-24 Thread Pete Templin
James Greig wrote: Anyone else have any other thoughts on this? Could it be a bug or a faulty backplane on the 6500 chassis? It looks similar to what I got when I toasted a chassis in November. I didn't capture the console output, but basically the primary Sup was OK but the rest were all

[c-nsp] 6509 problem

2010-01-22 Thread James Greig
Hi, Recently bought a standard 6509 + highspeed fan along with a WS-SUP32-GE-3B and 2x WS-X6148A-RJ-45. The 6500 boots up fine with the sup32, however, when it runs a diagnostic on the two switch modules (WS-X6148A-RJ-45) it fails stating: *Feb 28 22:29:29.055: %DIAG-SP-3-MAJOR: Module 1:

Re: [c-nsp] 6509 problem

2010-01-22 Thread Alan Buxey
Hi, *Feb 28 22:29:29.055: %DIAG-SP-3-MAJOR: Module 1: Online Diagnostics detected a Major Error. Please use 'show diagnostic result target' to see test results. what did the ouput of that command ('show diagnostic result target') give? *Feb 28 22:29:29.987: %OIR-SP-3-LC_FAILURE: Module 1

Re: [c-nsp] 6509 problem

2010-01-22 Thread James Greig
[mailto:a.l.m.bu...@lboro.ac.uk] Sent: 22 January 2010 21:03 To: James Greig Cc: cisco-nsp@puck.nether.net Subject: Re: [c-nsp] 6509 problem Hi, *Feb 28 22:29:29.055: %DIAG-SP-3-MAJOR: Module 1: Online Diagnostics detected a Major Error. Please use 'show diagnostic result target' to see test results. what