...@scripty.com]
Sent: 06 December 2009 00:15
To: Sony Scaria
Cc: cisco-nsp@puck.nether.net
Subject: Re: [c-nsp] Rmon checksum failed on WS-C4006
I have seen this problem many times on Catalyst 5000 and 6500 boxes.
The cause is NVRAM corruption which can often be resolved by rebooting
the Supervisor
Thanks Clinton. My Cisco TAC rep also recommends the same.
Sony.
-Original Message-
From: Clinton Work [mailto:clin...@scripty.com]
Sent: 06 December 2009 00:15
To: Sony Scaria
Cc: cisco-nsp@puck.nether.net
Subject: Re: [c-nsp] Rmon checksum failed on WS-C4006
I have seen this problem
Hi All,
I've observed Rmon checksum failed when I run sh ver on one of my catos
switch. The system is stable for a long time and I did not observe any
related logs. I had done some research , but couldn't gather any info on
Rmon checksum.
cat4013 (enable) sh ver
WS-C4006 Software,
I have seen this problem many times on Catalyst 5000 and 6500 boxes.
The cause is NVRAM corruption which can often be resolved by rebooting
the Supervisor in order to clear the issue. During reboot some of the
NVRAM configuration can be lost so make sure you have a proper backup to
compare