Hi Team,
I have been trying to set up multi-VM Clearwater set up for some time now.
Though the nodes seem to be running ok, the call is failing with 408
request time out. I can see the 408 time out on bono node.
(Was attaching the bono_current.txt file but got message from cleawaterlist
as the
, Aug 21, 2018 at 5:53 PM, Nishank Trivedi
wrote:
> Further investigation of bono_current. Txt shows some errors of not able
> to connect to 40.40.40.5 (sprout node) on port 5060. Using netstat - tulpn
> ред grep 5060 confirmed that nothing was running on 5060 on sprout.
>
> Fishy?
Hi Anne,
Thanks for replying.
Attaching the file for the relevant duration.
Thanks,
Nishank
On Tue, Aug 21, 2018 at 2:34 PM, Anne Boffey
wrote:
> Hi Nishank,
>
>
>
> A 408 Request Timeout could be coming from Clearwater (because its
> requests upstream are timing out) or from Zoiper (because
I can see 408 Request timeout in bono logs, as I mentioned in the initial
mail also.
What could be going wrong, here? Some zoiper setting? But, the request is
reaching Bono, so some clearwater setting,right.
Thanks,
Nishank
On Tuesday, August 21, 2018, Nishank Trivedi
wrote:
> Hi A
that
monit can restart. No change in error.
The next time, I also removed port 5060 from Outbound proxy setting on
zoiper. No change still.
Regards,
Nishank
On Tuesday, August 21, 2018, Nishank Trivedi
wrote:
> I can see 408 Request timeout in bono logs, as I mentioned in the initial
> mai
us research in this
complex area!
Thanks,
Nishank
On Tue, Aug 21, 2018 at 6:51 PM, Nishank Trivedi
wrote:
> Sorry for incessant posting, but I wish to update as I am making progress
> (?).
>
> I am attaching the bind DNS file for domain clearwater,opnfv and
> clearwater.loca