Bug#511395: mii-tool: link parter capabilities wrong

2009-10-02 Thread Ben Hutchings
Yes, the 1000BASE-T capabilities are clearly the wrong way round. Patch: --- net-tools-1.60.orig/mii-tool.c +++ net-tools-1.60/mii-tool.c @@ -355,9 +355,9 @@ printf(remote fault, ); printf((bmsr MII_BMSR_LINK_VALID) ? link ok : no link); printf(\n capabilities:%s,

Bug#511395: mii-tool: link parter capabilities wrong

2009-01-23 Thread Bjørn Mork
Package: net-tools Version: 1.60-22 Followup-For: Bug #511395 -BEGIN PGP SIGNED MESSAGE- Hash: SHA1 Just some additional data points for this bug. This interface is connected to a 100baseTx switch port. mii-tool shows the correct negotiation result, but seems to mixup the advertised

Bug#511395: mii-tool: link parter capabilities wrong

2009-01-10 Thread Kurt Roeckx
Package: mii-tool Version: 1.60-22 Hi, When looking at mii-tool -v's output, I see: eth0: negotiated 100baseTx-FD flow-control, link ok product info: Yukon 88E1011 rev 5 basic mode: autonegotiation enabled basic status: autonegotiation complete, link ok capabilities: 1000baseT-HD