Bug#930931: [pkg-bacula-devel] Bug#930931: /usr/sbin/btape: btape crashes on "fill" test

2020-11-08 Thread Sebastian Suchanek
Hi! For the avoidance of doubt: The bug I reported here and all the testing I did in 2019 around this bug report all took place on my Bacula production system. In the meantime, I did set up an independent test system in order to have more flexibility in testing and also to exclude hardware

Bug#930931: /usr/sbin/btape: btape crashes on "fill" test with kernel panic

2019-12-08 Thread Sebastian Suchanek
Update 2019-12-08: In the meantime, I've been able to source a second HP LTO5 drive. Unfortunately, also with the second drive, Bacula shows the exact same behaviour. In my opinion, with the error occuring also with a second drive, the possibility of a potential hardware problem is eliminated,

Bug#930931: /usr/sbin/btape: btape crashes on "fill" test with kernel panic

2019-06-22 Thread Sebastian Suchanek
-BEGIN PGP SIGNED MESSAGE- Hash: SHA1 Am 22.06.2019 um 22:20 schrieb Sven Hartge: > On 22.06.19 19:58, Sebastian Suchanek wrote: > >> - Put a cartridge in the drive - Run btape from console: "btape >> -c /etc/bacula/bacula-sd.con /dev/nst1" - Start "f

Bug#930931: /usr/sbin/btape: btape crashes on "fill" test with kernel panic

2019-06-22 Thread Sebastian Suchanek
Package: bacula-sd Version: 9.4.2-1~bpo9+1 Severity: normal File: /usr/sbin/btape Dear Maintainer, running a "fill" test in btape on a HP LTO-5 (type: BRSLA-0901-DC) results in a kernel panic. What I did: - Put a cartridge in the drive - Run btape from console: "btape -c