Reassembled XOs fail heat spreader test

2011-07-22 Thread Sridhar Dhanapalan
We are currently engaged in changing the motherboards in over a hundred XO-1.5s. In many cases, the XOs are failing the heat spreader test afterwards. However, we can get the test to pass if we press down on the lid, behind the screen. This suggests to me that the heat spreader is not in proper

Re: Reassembled XOs fail heat spreader test

2011-07-22 Thread John Watlington
Do your heat spreaders have four screws or three ? The final heat spreader for XO-1.5 production had four screws holding it down, to ensure a good fit.If your heat spreaders only have three, OLPCA should be able to get proper replacements from Quanta. Regards, wad On Jul 22, 2011, at 10:35

Re: Reassembled XOs fail heat spreader test

2011-07-22 Thread Samuel Greenfeld
The unused hole actually is filled by one of the screws which holds in the rear plastic panel. That's why the screw holes which only secure the heat spreader have arrows pointed at them. The fanciest (newest?) XO-1.5 heat spreader design I've seen adds a support bar up to the green screw hole

Re: Reassembled XOs fail heat spreader test

2011-07-22 Thread Sridhar Dhanapalan
Thanks Samuel. I'll be talking in more depth with OLPCA about this. Any suggestions on how to deal with this in the meanwhile are welcome :) I have found that it can help to bend the spreader near the screw points to make it slightly concave. However, I agree with you that this is not a good