Hello,
I'm trying to solve a problem that when I start/stop my flowgraph to
reconfigure recording to file, a fatal error regarding missing tag length
is posted by the tagged stream to pdu block. This block follows a stream
to tagged stream block.
It's the problem that this person was having in
Hello,
I'm encountering an error in my flowgraph that involves tag propagation
when stopping/starting. The flowgraph has a USRP connected to file meta
sinks. The USRP can be switched by the user to stream to a null sink when
recording of data is not required. When this happens, the file sinks
hello
i write a grc,i use the virtual sink and virtual source,the grc woked well
when i replace the virtual sin and source with usrp sink and source,there is a
problem occured
the message is:
gr::log :FATAL: repack_bits_bb0 - Missing a required length tag on port 0 at