Hi folks:
Just finished a 4-band k1, and thought I had low power out on all bands.
Turns out the cable from rig to meter was open on the ground side (a
cable Xperts cord). At 5 W requested, I now get 5 w on 20, 30, and 40
meters, and about 4-4.5 on 15. A 7 watts requested (the maximum on the
Ted,
That is about normal for a good K1. 5 watts or more on all bands is to
be expected - most will do more.
73,
Don W3FPR
Ted Holland wrote:
Hi folks:
Just finished a 4-band k1, and thought I had low power out on all
bands. Turns out the cable from rig to meter was open on the ground
I will echo what was already mentioned. Your measurements are about the same
as what I get on my K1. 15 meters has always been a bit lower than the
other bands.
One other thing I have noticed is that the power readout on the K1 is not
linear across the bands. I checked mine with a fairly
:[EMAIL PROTECTED] On Behalf Of WA6L
Sent: Monday, January 28, 2008 1:06 PM
To: elecraft@mailman.qth.net
Subject: Re: [Elecraft] K1 power output question
I will echo what was already mentioned. Your measurements are about the
same
as what I get on my K1. 15 meters has always been a bit lower than
4 matches
Mail list logo