Anyone know if the frequency counter mode of the MFJ-259B is accurate
enough to do the 4 MHz Oscillator Calibration of the K2?
Thanks
--
JT Croteau, N1ESE - Manchester, NH
___
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a
JT,
No way! Wait until you have completed the K2 and use the method
described on the Elecraft website to accurately set the 4 MHz reference
using 10 MHz WWV or other accurately known frequency standard station -
follow that with a CAL PLL and CAL FIL to produce accurate dial
calibration on
JT Croteau wrote:
Anyone know if the frequency counter mode of the MFJ-259B is accurate
enough to do the 4 MHz Oscillator Calibration of the K2?
No.
Use the N6KR method, described on the Elecraft Website.
http://www.elecraft.com/Apps/K2%20C22%20Adjust%20App%20Note.pdf
--
73,
Vic, K2VCO
Fresno
3 matches
Mail list logo