Andre,
Do you have any power control? To check set the power to about 50 watts
and do a TUNE. Measure the actual power output with an in-line
wattmeter and a 50 ohm dummy load.
If it still goes to 160 watts, you do not have any power control. The
usual reason is the diodes D16 and D17
Hi, Andre -
I wonder if it's a problem with blown D16 and D17 in the KPA100.
If you follow this forum on-line at nabble.com, you can do a search for
"D16" and
see many postings on the topic.
Good luck.
- Bruce K1FFX
-
Bruce Rosen
K1FFX
K2/100 6982 KSB2 KAT100-1 KAF2 KIO2
--
Sent from:
Dear All,
I gave a new home to a K2 + (KPA100+KAT100 in EC 2), ser#>5000. The K2
on its own is runnung fine.
When I connect to the KPA+KAT I get HiCur warning (on initiating TX) on
all bands with POW>10W. This also happens when I transmit into a dummy
load. I measured the output from the
3 matches
Mail list logo