Thanks to all who responded. Checked and realigned all connectors, no
apparent errors, all male pins in place, connectors firmly seated.
Removed KRX3 and SUBIN/OUT module, reinstalled and reconnected. Similar
advice received both from group and from Elecraft support.
Still same problem, main rx
...@mailman.qth.net] On Behalf Of Matt
Zilmer
Sent: Thursday, May 4, 2017 11:44 AM
To: elecraft@mailman.qth.net
Subject: Re: [Elecraft] K3 with subrx - intermittent main RX problem and pwr out
Sorry to be thick Is a dry joint same as a cold joint?
Thanks and 73,
matt W6NIA
On 5/4/2017 9:12 AM
>
> -Original Message- From: Victor Rosenthal 4X6GP
> Sent: Thursday, May 4, 2017 3:07 PM
> To: elecraft@mailman.qth.net
> Subject: Re: [Elecraft] K3 with subrx - intermittent main RX problem
> and pwr out
>
> Well, I had a relay fail on my KAT3 board. I d
Solder lug/solder tag/tag washer all the same thing. :-)
Perhaps instead of dry joint I should have said "broken joint". The bond
between the solder lug and the connecting wire had become broken,
resulting in the effect of a dry joint. This could have been caused by
someone being over
17 5:43 PM
To: elecraft@mailman.qth.net
Subject: Re: [Elecraft] K3 with subrx - intermittent main RX problem and pwr
out
Sorry to be thick Is a dry joint same as a cold joint?
Thanks and 73,
matt W6NIA
__
Elecraft mailing list
"Two countries separated by a common language." I believe "tag washer"
is a "solder lug" on our side of the Atlantic. I think Alan might mean
the screw connection on that lug becoming intermittent due to oxidation
and/or inadequate tightening. Generally speaking, cold solder joints
are
I had this happen with the 2M module, too. What I do now with these is try to
support the little teflon insulator in the socket from the rear with a small
flat-blade screwdriver — at least the ones I get to that way.
Took a while to figure out what the problem was, since everything looks
] On Behalf Of la3rk
Sent: Thursday, May 4, 2017 12:32 AM
To: elecraft@mailman.qth.net
Subject: [Elecraft] K3 with subrx - intermittent main RX problem and pwr out
I have a K3 approx 8 years old. Fully equipped with subrx, 100W PA, antenna
tuner and in/out module.
When I connect the subrx, the main
: [Elecraft] K3 with subrx - intermittent main RX problem
and pwr out
Well, I had a relay fail on my KAT3 board. I don't remember which one.
Elecraft sent me a replacement. It wasn't hard to replace, but it
happens.
73,
Victor, 4X6GP
Rehovot, Israel
Formerly K2VCO
http://www.qsl.net/k2vco/
On 4 May
under test.
73,
Alan. G4GNX
-Original Message-
From: Victor Rosenthal 4X6GP
Sent: Thursday, May 4, 2017 3:07 PM
To: elecraft@mailman.qth.net
Subject: Re: [Elecraft] K3 with subrx - intermittent main RX problem and pwr
out
Well, I had a relay fail on my KAT3 board. I don't remember which
Also make sure TMP connectors to and from synthesizer/KREF/Subrx boards
are secure.
Brian/K3KO
On 5/4/2017 13:46 PM, Don Wilhelm wrote:
Olaf,
The relays used by Elecraft are quite reliable, so I suspect that is not
a reasonable source of the problem. In more than 12 years of repairing
the
Well, I had a relay fail on my KAT3 board. I don't remember which one.
Elecraft sent me a replacement. It wasn't hard to replace, but it happens.
73,
Victor, 4X6GP
Rehovot, Israel
Formerly K2VCO
http://www.qsl.net/k2vco/
On 4 May 2017 16:46, Don Wilhelm wrote:
Olaf,
The relays used by
Must underscore what Don said. Busted BNC connector/coax wiring is so
very common. If they were hand-done with soldering iron and NOT RG400
coax (teflon, won't melt) or were not crimped with specific tool
required for the specific connector and specific coax, they are more
likely to go bad over
Olaf,
The relays used by Elecraft are quite reliable, so I suspect that is not
a reasonable source of the problem. In more than 12 years of repairing
the Elecraft legacy gear (more than 1200 repairs), I have had to replace
only a small handful of relays due to failure. I have replaced
I have a K3 approx 8 years old. Fully equipped with subrx, 100W PA, antenna
tuner and in/out module.
When I connect the subrx, the main rx sometimes loses signal and at the same
time power out goes to zero.
Looking at the diagrams, I suspect there is an intermittent contact problem
in relay K1
15 matches
Mail list logo