[Emc-developers] TP_MIN_SEGMENT_CYCLES

2015-04-18 Thread biematic
In the Tp_types.h, it says like following:/* Minimum length of a segment in cycles (must be greater than 1 to ensure each * segment is hit at least once.) */ #define TP_MIN_SEGMENT_CYCLES 1.02 I cannot understand the description, what does the TP_MIN_SEGMENT_CYCLES represent, can anyone explain

Re: [Emc-developers] Fwd: Re: Reverse Run

2015-04-18 Thread TJoseph Powderly
Andy sorry didnt get this out earlier, had to go out of town for work (yay work :) but yes, there is no acceleration limit while edming ( for heidenhain sink eroders, i doubt you'll find as much internal info from other mfctrs ) some may say that ignoring acc is just wrong but thats not from

Re: [Emc-developers] Realtime scheduling

2015-04-18 Thread Gene Heskett
On Saturday 18 April 2015 01:56:37 Karlsson Wang wrote: I am running linxucnc via ethernet and have studied the CPU and network load. The minimum servo period seems to be around 200µs despite both CPU load and network load is low. I have not yet investigated if this is because network packets