[PSES] PoE IEEE 802.3AF

2013-09-10 Thread Kevin Newland
Hi Group,   Does anyone know what the maximum capacitor that is allowed in a design in order to be IEEE 802.3AF compliant? I don't know the limit.   thank you Kevin - This message is from the IEEE Product Safety Engineering Society

Harmonic limits

2000-12-21 Thread Kevin Newland
Hello All, I have been told that on EN61000-3-2 (harmonic standard)the class A limit is much easier than class D, but when I look at the two tables, they look almost identical. Could someone explain to me the difference between the two limits (A D) and also which of the two limit column in the

Re: Testing of product per en60825-1

2000-09-25 Thread Kevin Newland
Bharat, Nemko do this type of test. They have offices worldwide. Thanks Kevin --- bharat_s...@logitech.com wrote: Hello, Is there any independent laboratory who can conduct the test per EN60825-1 ? Thank you, Regards, Bharat Shah ---

Re: Argentina IRAM

2000-09-21 Thread Kevin Newland
George, Their web site is : www.iram.com.ar Thanks Kevin --- George Sparacino george.sparac...@bostonacoustics.com wrote: Hello All.. Does anyone have a URL for the IRAM homepage .. in English ?? Thanks, George __ Do You Yahoo!? Send

Re: Russian Certification of Products and other countries

2000-03-16 Thread Kevin Newland
can, I will change my Job immediately. Rene Charton Kevin Newland kevin_newl...@yahoo.com on 03/16/2000 06:59:11 AM Please respond to Kevin Newland kevin_newl...@yahoo.com To: Maxwell, Chris chr...@gnlp.com, 'EMC-PSTC Internet Forum' emc-p...@majordomo.ieee.org cc

Re: Russian Certification of Products

2000-03-15 Thread Kevin Newland
Chris, Just remember that with the exception of Western European countries,USA and Canada, the rest of the world (without being rude) have not really have a solid rule for anything. These countries rules and regulation changes daily (just like stock exchange) without any notice or explanation).

Re: CCTV CAMERA to LVD

2000-03-10 Thread Kevin Newland
Peter, I am afraid I disagree with Richard. The CCTV comes under the scope of IEC65 and not 950. Thanks Kevin --- Peter Merguerian pmerguer...@itl.co.il wrote: Hello Group, Can EN 60 950 be used to evaluate a CCTV camera to the LVD? Peter Merguerian Managing Director Product Testing

EMC for medical devices

2000-01-25 Thread Kevin Newland
Hello All, Could someone let me know the answer to the following questions please: 1-What are the immunity standards used in Europe for medical devices? 2-What EMC standards is used in US/Canada for medical devices? The product in question is approved for safety to IEC601-1. Thank you

RE: ITE Requirements for India?

2000-01-05 Thread Kevin Newland
Charles, Try the following web site: http://wwwdel.vsnl.net.in./bis.org/ This is the Bureau of Indian Standards Thanks Kevin __ Do You Yahoo!? Talk to your friends online with Yahoo! Messenger. http://im.yahoo.com - This message is

Re: ITE Requirements for India?

2000-01-05 Thread Kevin Newland
Scott, As far as I know, India requirements for ITE is IEC950 and CISPR22. However you can get the latest information directly from the government officials, details of which is listed below: Director ( Central Marks ) Bureau of Indian Standards Manak Bhavan 9 Bahadur Shah Zafar Marg New Delhi