Re: [PSES] Radiated Spurious Emission cause of new antenna

2017-10-18 Thread Charlie Blackham
ales, number 05466247 -Original Message- From: Amund Westin [mailto:am...@westin-emission.no] Sent: 18 October 2017 12:03 To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: [PSES] Radiated Spurious Emission cause of new antenna A radio module is tested and certified according to EN 300 328 and RED.

[PSES] Radiated Spurious Emission cause of new antenna

2017-10-18 Thread Amund Westin
A radio module is tested and certified according to EN 300 328 and RED. The module is then installed in an end-product, but with another antenna than was used under the module test and certification process. A notified body now asks for a new Radiated Spurious Emission test beacuse of the new