Re: [PSES] Transient and Surge Test per ISO7637-2

2012-02-15 Thread Steve O'Steen
John/all, In the process of my research on this topic I've uncovered several references and links to a Commission Recommendation http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2008:098:0024 :0027:EN:PDF This recommendation addresses Mobile Communication Services on Aircraft

[PSES] Transient and Surge Test per ISO7637-2

2012-02-14 Thread Steve O'Steen
All, I was reviewing Table 2, Immunity Requirements for a DC Powered Device intended for use in commercial Aircraft. This would integrated into the DC power system of the aircraft and not meant to be carried on and off the aircraft. I assume that an aircraft meets the definition of a vehicle so

Re: [PSES] Transient and Surge Test per ISO7637-2

2012-02-14 Thread Ron Pickard
-160 Environmental Conditions and Test Procedures for Airborne Equipment. IHTH. Best regards, Ron From: Steve O'Steen [mailto:steve.ost...@acstestlab.com] Sent: Tuesday, February 14, 2012 7:03 AM To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: [PSES] Transient and Surge Test per ISO7637-2 All, I

Re: [PSES] Transient and Surge Test per ISO7637-2

2012-02-14 Thread John Woodgate
In message 1e8310e20735fa4bb42f127880b293e601902...@acsmail.acs.local, dated Tue, 14 Feb 2012, Steve O'Steen steve.ost...@acstestlab.com writes: .  I assume that an aircraft meets the definition of a vehicle so I started down the path of applying the immunity requirements for Radio and