At 4:22 PM -0500 12/18/98, Doug Frazee wrote: >I would like to compile thoughts and techniques that members of this group >use to perform "in situ" tests on large industrial apparatus. The basic protection requirements of the EMC directive state in effect that the apparatus shall not cause undue i

RE: EMC Directive Field Testing of Large Equipments

1998-12-19 Thread Brumbaugh, David
8 1:22 PM > To: 'emc-p...@majordomo.ieee.org' > Subject: EMC Directive Field Testing of Large Equipments > > I would like to compile thoughts and techniques that members of this group > use to perform "in situ" tests on large industrial apparatus. > Consi

EMC Directive Field Testing of Large Equipments

1998-12-18 Thread Doug Frazee
I would like to compile thoughts and techniques that members of this group use to perform "in situ" tests on large industrial apparatus. Considerations I have typically encountered include: Current draw in excess of available LISN capacity. Use CISPR voltage probe Current draw in excess of av