Re: Oils for the 950 Hot Flaming Oil Test

2001-07-26 Thread Andrew Carson
True, sound scientific reasoning. But this is UL and the next question to ask is do you have the correct specification Cheese Cloth and Pine Wood board. This is a serious question one asked by a visiting Engineer ! Robert Johnson wrote: If you are looking for a specification for the oil, the

Re: Oils for the 950 Hot Flaming Oil Test

2001-07-26 Thread Robert Johnson
If you are looking for a specification for the oil, the MSDS is not necessarily the appropriate place to look. The MSDS is for the purpose of defining toxicity and similar risks and is often the same for a range of materials. As we were writing the standards we found it difficult to come up

RE: Oils for the 950 Hot Flaming Oil Test

2001-07-26 Thread Dick Grobner
for the 950 Hot Flaming Oil Test Dear All, Does anyone have the MSDS for Kerosene # 1? This is the oil used by UL to conduct the Hot Flaming Oil Test in the UL60950/EN 60 950 ITE standards when the bottom openings do not comply with some of the bottom cfonstructions specified in the standard. I

RE: Oils for the 950 Hot Flaming Oil Test

2001-07-26 Thread David_Sterner
, July 26, 2001 3:19 AM To: EMC-PSTC (E-mail) Subject: Oils for the 950 Hot Flaming Oil Test Dear All, Does anyone have the MSDS for Kerosene # 1? This is the oil used by UL to conduct the Hot Flaming Oil Test in the UL60950/EN 60 950 ITE standards when the bottom openings do not comply

RE: Oils for the 950 Hot Flaming Oil Test

2001-07-26 Thread Roman, Dan
?searchdata=P339int=false Dan -Original Message- From: Peter Merguerian [mailto:pmerguer...@itl.co.il] Sent: Thursday, July 26, 2001 3:19 AM To: EMC-PSTC (E-mail) Subject: Oils for the 950 Hot Flaming Oil Test Dear All, Does anyone have the MSDS for Kerosene # 1? This is the oil used

Oils for the 950 Hot Flaming Oil Test

2001-07-26 Thread Peter Merguerian
Dear All, Does anyone have the MSDS for Kerosene # 1? This is the oil used by UL to conduct the Hot Flaming Oil Test in the UL60950/EN 60 950 ITE standards when the bottom openings do not comply with some of the bottom cfonstructions specified in the standard. I am also trying to determine