RE: Query on dealing with BSMI for EMC

2008-07-09 Thread Knighten, Jim L
Alain, Thanks for the help. Jim James L. Knighten, Ph.D. EMC Engineer Teradata Corporation 17095 Via Del Campo San Diego, CA 92127 858-485-2537 – phone 213-337-5432 – fax From: alain.samlai (岑國綸) [mailto:alain.sam...@gigabyte.com.tw] Sent:

Re: Query on dealing with BSMI for EMC

2008-07-08 Thread reheller
Jim, Go to: ts.nist.gov/standards/conformity/mra/mra.cfm Select: APEC Tel MRA Select: How to apply for CAB designation under the APEC Tel MRA Bob Heller 3M EMC Laboratory, 76-1-01 St. Paul, MN 55107-1208 Tel: 651- 778-6336 Fax: 651-778-6252

Re: Query on dealing with BSMI for EMC

2008-07-08 Thread Grace Lin
Jim, You don't need a number if you follow the instruction Bob provided (to have NVLAP include the CNS 13438 scope). BSMI does conduct laboratory assessment for labs located outside of Taiwan. There is no benefit to go through this route if your lab is NVLAP/A2LA accredited. For Taiwan's

RE: Query on dealing with BSMI for EMC

2008-07-07 Thread alain.samlai (岑國綸)
Dear Jim, As far as I understand BSMI, BSMI only regulates standards (the S) and inspections (the I). For laboratory accreditation, you may need to contact the Taiwan Accreditation Foundation (TAF) or ILAC for MRA. Hope this may be of some help. Alain