Re: [PSES] Impact on NRTL Certification - Refurbished/Remanufactured Products

2012-07-09 Thread Knudsen, Patricia
My company sells a lot of refurbished products. They all go through the factory, are built using the approved components in the safety report, and get production line tests before they go out the door. Our NRTL knows we do this and they have the option of inspecting the refurbished products

[PSES] Fwd: Sr Compliance/Safety Engineer position, laser equipment company, Portland area

2012-07-09 Thread Doug Nix
Fellow EMC-PSTC listers: Below is a job opening I heard about through the grapevine that you may be interested in. I have nothing to do with the employer or any recruiters, asn I ask that you cpntact Gerry Mohr, +1 (503) 226-3777, ge...@lightsourceconsulting.co,

[PSES] Original Signed Reports Versus Digital Scanned Reports for EMC Technical Files

2012-07-09 Thread Monrad Monsen
We have EMC lab currently files and saves the original signature documents for every test report. However, we retain the electronic scan copy version of the reports which are backed up and have disaster recovery procedures in place for off-site storage. We would like to stop saving the paper

Re: [PSES] Original Signed Reports Versus Digital Scanned Reports for EMC Technical Files

2012-07-09 Thread Doug Powell
Monrad, I am not aware of any need to save hard copy reports, especially after enough time has elapsed. Document retention in the EU for liability directive is still 10 years (you might double check that). Otherwise, I have been doing electronic submittals (of safety reports) to my