Hi Rich- I think the OP was asking more about how far apart two Mains
inlets could be while still being covered under the same "remove
all linecords" warning label (not electrical/breakdown spacing).
Robert: You are probably OK as long as there are no service positions from
which you can't see bot
Hi Robert:
The insulation, including spacings, between two mains inputs are functional
insulations, not safeguard insulations. IEC 60950-1 has some functional
insulation requirements. IEC 62368-1 has no functional insulation
requirements because functional insulation is not safeguard insul