Re: [PSES] IEC 62368-1 compliance for Equipment w Two AC Entries

2017-11-15 Thread IBM Ken
Hi Rich- I think the OP was asking more about how far apart two Mains inlets could be while still being covered under the same "remove all linecords" warning label (not electrical/breakdown spacing). Robert: You are probably OK as long as there are no service positions from which you can't see bot

Re: [PSES] IEC 62368-1 compliance for Equipment w Two AC Entries

2017-11-15 Thread Richard Nute
Hi Robert: The insulation, including spacings, between two mains inputs are functional insulations, not safeguard insulations. IEC 60950-1 has some functional insulation requirements. IEC 62368-1 has no functional insulation requirements because functional insulation is not safeguard insul