Re: [Emc-users] parameter SCALE

2010-01-18 Thread Chris Radek
On Mon, Jan 18, 2010 at 06:05:56PM +0300, ??? ? wrote: Hello guys As I understand from manual SCALE defines number of pulses that corresponds to a move of one machine unit. Right. It must be integer, but not float, because it is not possible to generate 1,5 pulses.

Re: [Emc-users] parameter SCALE

2010-01-18 Thread Jeff Epler
SCALE is not restricted to whole numbers. Make sure to use . as the decimal point, not ,: [AXIS_0] SCALE = 166.667 Jeff -- Throughout its 18-year history, RSA Conference consistently attracts the world's best and

Re: [Emc-users] parameter SCALE

2010-01-18 Thread Евгений Александрович
Oh guys, my mistake, thanks This is wrong. It does not need to be an integer. Well, but I have problem this case. I have axis A with 166,667 pulses for one grad. I could to set SCALE to 167, but this case I will have error about 0,5 grad for whole turn. How can i solve this