Re: new interrupts not working for me

2003-11-11 Thread Richard Todd
John Baldwin wrote: On 06-Nov-2003 Peter Schultz wrote: John Baldwin wrote: On 05-Nov-2003 Peter Schultz wrote: I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my adaptec scsi controller, I get a whole bunch of output like this hand

Re: new interrupts not working for me

2003-11-06 Thread John Baldwin
On 06-Nov-2003 Peter Schultz wrote: John Baldwin wrote: On 05-Nov-2003 Peter Schultz wrote: I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my adaptec scsi controller, I get a whole bunch of output like this hand transcribed bit, it comes

Re: new interrupts not working for me

2003-11-06 Thread Peter Schultz
John Baldwin wrote: On 06-Nov-2003 Peter Schultz wrote: John Baldwin wrote: On 05-Nov-2003 Peter Schultz wrote: I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my adaptec scsi controller, I get a whole bunch of output like this hand

new interrupts not working for me

2003-11-05 Thread Peter Schultz
I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my adaptec scsi controller, I get a whole bunch of output like this hand transcribed bit, it comes after waiting 15 seconds for scsi devices to settle: ahc0 timeout SCB already complete interrupts

Re: new interrupts not working for me

2003-11-05 Thread Reko Turja
- Original Message - From: Peter Schultz [EMAIL PROTECTED] Newsgroups: mailing.freebsd.current Sent: Thursday, November 06, 2003 12:55 AM Subject: new interrupts not working for me I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my

RE: new interrupts not working for me

2003-11-05 Thread John Baldwin
On 05-Nov-2003 Peter Schultz wrote: I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my adaptec scsi controller, I get a whole bunch of output like this hand transcribed bit, it comes after waiting 15 seconds for scsi devices to settle:

Re: new interrupts not working for me

2003-11-05 Thread Peter Schultz
John Baldwin wrote: On 05-Nov-2003 Peter Schultz wrote: I have a Tyan S1832DL w/dual pii 350s and it's not able to boot. Seems to be having trouble with my adaptec scsi controller, I get a whole bunch of output like this hand transcribed bit, it comes after waiting 15 seconds for scsi devices