Den 2018-09-05 kl. 13:01, skrev Gmx QA:
Hi all,
I am running a series of umbrella sampling simulations of a drug across a
membrane, with the final aim to determine permeability using the local
diffusion model.
I have come across papers where the (necessary) autocorrelation times of
the
On 9/5/18 9:25 AM, milad bagheri wrote:
I'm going to examine the interaction between the two proteins using
molecular dynamics simulation by gromacs, so I downloaded pdb code 5op1
from the rcsb , which has two protein(Complex). I want to create a gap
between two protein, and then with the
On 9/5/18 1:50 AM, Rakesh Mishra wrote:
So that means
It is may be due to the difference in the type of interaction.
and I can not understand your this statement "you have to contend with
forces principally acting perpendicular to the direction of the bias"
Well, what interactions act
It's not the first time you're posting this message and there's a reason
noone is replying.
1. What are the inter-axis angles of that orthorhombic box? Why not a
rectangular box?
2. Why are you using LINCS with graphene, which should _not_ be simulated
with constraints?
3. Why are you restraining
Dear all,
Can simulation for orthorhombic structure be done in gromacs?
Actually I am working with 2-D graphene sheets which are like a
parallelogram.
In my system, there is a graphene sheet (restrained)and water.
After the energy minimization, energy is coming positive (order of 10^8)
On
Hi all,
I would like to use Gromacs (2018 versions on GPUs) to compute solvation free
energies using expanded ensemble simulations. I have no problems in the NVT
ensemble, but when I try and implement pressure control I run into errors.
Specifically, if I want to use expanded ensemble, I must
Dear all,
The compilation of the Gromacs.2018.2 on a cluster terminated with error in
below step, would you please let me know how I can overcome the issue? I
use gcc/7.3.0.
[ 0%] Building C object
src/gromacs/CMakeFiles/tng_io_zlib.dir/__/external/tng_io/external/zlib/crc32.c.o
cd
Hi Olga,
The authors of:
https://github.com/bio-phys/MDBenchmark/tree/version-1.3.2
https://zenodo.org/record/1318123
May be helpful. If your data is not confidential, you may consider
running Gromacs remotely on a cloud high performance computing resource,
or benchmarking remotely and then
Hi Supid,
Got the point. Thanks a lot.
On Wed, Sep 5, 2018 at 2:05 AM, Sudip Das wrote:
> Hi Andrew,
> Follow the below link. Hope that helps.
>
> http://www.gromacs.org/Documentation/How-tos/Tool_Changes_for_5.0 (follow
> the 'g_sas' section)
>
> Regards,
> Sudip
>
> On Wed, Sep 5, 2018 at
I'm going to examine the interaction between the two proteins using
molecular dynamics simulation by gromacs, so I downloaded pdb code 5op1
from the rcsb , which has two protein(Complex). I want to create a gap
between two protein, and then with the same coordinate Put these two
proteins in a box
Hi all,
I am running a series of umbrella sampling simulations of a drug across a
membrane, with the final aim to determine permeability using the local
diffusion model.
I have come across papers where the (necessary) autocorrelation times of
the mean-squared fluctuation of the coordinates are
Hi Andrew,
Follow the below link. Hope that helps.
http://www.gromacs.org/Documentation/How-tos/Tool_Changes_for_5.0 (follow
the 'g_sas' section)
Regards,
Sudip
On Wed, Sep 5, 2018 at 9:56 AM Andrew Srimalka Wijesekera <
2014s14...@stu.cmb.ac.lk> wrote:
> Dear all,
>
> I'm currently studying
Hello,
I need help in choice of the workstation for MD simulations using GROMACS.
It is supposed to study systems consisting from 30-50k atoms, in
particular, lipid bilayer models. Since the last generation of Intel and
Ryzen CPU has made a big leap in performance, available workstation can’t
be
13 matches