Den 2019-05-10 kl. 00:42, skrev Shadi Fuladi:
Hi,
I'm trying to test molecular oxygen diffusion in electrolytes using OPLS
force field. Is there any O2 parameters tested with OPLS AA forcefield?
Thanks,
SF
There is a model described here
Hub, J. S.; de Groot, B. L. Proc. Natl. Acad. Sci.
Yup, your assessment agrees with our guess. Our HPC guru will be taking his
findings, along with your quote, to the admins.
Thank you,
Alex
On Thu, May 9, 2019 at 2:51 PM Szilárd Páll wrote:
> On Thu, May 9, 2019 at 10:01 PM Alex wrote:
>
> > Okay, we're positively unable to run a Gromacs
Hi,
I'm trying to test molecular oxygen diffusion in electrolytes using OPLS
force field. Is there any O2 parameters tested with OPLS AA forcefield?
Thanks,
SF
--
Gromacs Users mailing list
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
On Thu, May 9, 2019 at 10:01 PM Alex wrote:
> Okay, we're positively unable to run a Gromacs (2019.1) test on Power9. The
> test procedure is simple, using slurm:
> 1. Request an interactive session: > srun -N 1 -n 20 --pty
> --partition=debug --time=1:00:00 --gres=gpu:1 bash
> 2. Load CUDA
Okay, we're positively unable to run a Gromacs (2019.1) test on Power9. The
test procedure is simple, using slurm:
1. Request an interactive session: > srun -N 1 -n 20 --pty
--partition=debug --time=1:00:00 --gres=gpu:1 bash
2. Load CUDA library: module load cuda
3. Run test batch. This starts
Dear Users,
In using:
gmx density -f lipid.nvt.trr -s octanoate.nvt3.tpr -dens charge -center -symm
-sl 100 -b 4 -e 4.5
it appears that the average charge density of all frames and the total box size
is used in the calculation. Is there a way to
1) specify multiple ranges to output say, every
hello all,I am running an md simulation using gromacs 2019 with RDC restraints
added in all steps, now in my log file i get something like this Orientation
experiment 1:
order parameter: -0.00156791
eig: 1.000 -0.085 0.037 0.996
eig: -0.636 -0.144 0.988 -0.049
eig: -0.364
Dr. Shirts,
Thank you for the swift reply.
> If you have "unprotected" electrostatic sites (i.e. with nonzero repulsive
> terms directly on top of the charge), then there will always be some
> configurations with essentially infinitely negative energy.
That makes sense. Definitely something to
If you have "unprotected" electrostatic sites (i.e. with nonzero repulsive
terms directly on top of the charge), then there will always be some
configurations with essentially infinitely negative energy. For vanilla
MD, these are essentially impossible to reach kinetically at any reasonable
Hi all,
I have a rather strange question that I hope someone can shed some light on.
Before I begin, I want to note that I am pioneering some new developments
of the Adaptive Resolution Simulation technique
(https://doi.org/10.1002/adts.201900014), so the simulations/techniques I
am
Dear Users,
It is known that electric dipole moment of a water monomer is
experimentally 1.85 D and using the TIP3P model it's supposed to be 2.35D.
I am using the TIP3P model for a water-based simulation in Gromacs 5.1.5.
After applying sinusoidal electric fields in the Y axis, the norm of the
This will do it (if need particular water model change with cs switch
options, and assumes ligand.gro has the correct final box size)
gmx solvate - cp ligand.gro -cs -o complex.gro
Unless you have a particular number of waters required, then use.:
gmx solvate - cp ligand.gro -cs -o complex.gro
Hi Users.
I want to simulate ligand in the water box. I prepared a water molecule and
started with pdb2gmx and then planned to follow protein-ligand tutorial.
Unfortunately ended up with an error in gro file format. Have check every
possibility but still couldn't find any solution.
My initial pdb
Make index of water mediated hydrogens and DNA bases so that DNA bases are
in separate group and water mediated hydrogens in separate group in drop
down menu
On Thu, May 9, 2019, 11:54 AM wrote:
> Dear all
> I want to determine the water mediated hydrogen between DNA bases and
> small molecule.
Hi,
I think it will still work if you use the "gau": script found here:
http://wwwuser.gwdg.de/~ggroenh/qmmm.html#gaussian
best,
Gerrit
On 5/7/19 9:59 PM, ??? wrote:
> Dear Gromacs support,
> I want to install Gromacs 2018.5 with gaussian09 software support in Centos
> system, I try to
Dear all
I want to determine the water mediated hydrogen between DNA bases and
small molecule. What extra flag should I use in gmx hbond command? Is
there any other option to capture the water mediated Hbonds? Please
suggest something.
Sunipa Sarkar
--
Gromacs Users mailing list
* Please
Den 2019-05-08 kl. 16:21, skrev Akash Banerjee:
Dear Gromacs Developer,
I want to use the implicit solvent (gbsa algorithm) along with User-defined
tabulated potentials. Apparently, the implicit solvent option is not
compatible with the vdw-type=USer option. Can I please get some advice on
17 matches
Mail list logo