Dear Expert,
I am trying to using TopupPreprocessingAll.sh on my own EPI data. I have looked
TopupPreprocessingAll.sh line 254
${FSLDIR}/bin/fslmaths ${WD}/TopupField -mul 6.283 ${WD}/TopupField
What is this 6.283, do I need make change according to my acquisition setting?
Thanks.
Jian Chen
It is the conversion factor from Hz to radians/sec: 2*pi = 6.283
You want to leave that as is.
cheers,
MH
--
Michael Harms, Ph.D.
---
Conte Center for the Neuroscience of Mental Disorders
Washington University School of Medicine
From: Stamatios Sotiropoulos stamatios.sotiropou...@ndcn.ox.ac.uk
Date: Thursday, June 4, 2015 at 10:36 AM
To: Matt Glasser glass...@wusm.wustl.edu
Subject: Re: [HCP-Users] Error Running Probtrackx
Hi
This is not released yet. If you call bedpostx or xfibres without any parameters
Thats a question for Stam, but if you want 3 fibers, you would need to run --nf=3.
Peace,
Matt.
From: Archer, Derek B arche...@ad.ufl.edu
Date: Thursday, June 4, 2015 at 9:30 AM
To: Matt Glasser glass...@wusm.wustl.edu, hcp-users@humanconnectome.org hcp-users@humanconnectome.org