Re: Yahoo

2011-02-28 Thread Darren Evans-Young
The Listserv discussion list IBM-MAIN has nothing to do with yahoo.com. Someone else setup a yahoo group called IBM-MAIN-OT. I have no privileges to change anything about that group. According to yahoo, someone needs to contact: ibm-main-ot-ow...@yahoogroups.com and have them alter the settings.

ZCIOWAIT message

2011-02-28 Thread Eric JL
When I run a CICS trans, it is use for DB2 select update, found it spend a lot of time on ZCIOWAIT. Is this a problem? How can I optimize it. The trans dump DATE TIME JOBNAME TRANID TASK# TERMID RESP CPU PAGING ILEIO 02/24 00:00:01 CICSA TR68 85748111.097 0.2186 0

Re: MFNetDisk tape emulation code and request code

2011-02-28 Thread Richard Pinion
I like the way you manage the code and the request form! Richard, Vickie, and Randy Pinion --- shai.h...@gmail.com wrote: From: Shai Hess shai.h...@gmail.com To: IBM-MAIN@bama.ua.edu Subject: MFNetDisk tape emulation code and request code Date: Sun, 27 Feb 2011 13:01:48 -0600 HI, I

Re: Moving from XCF-local to single-system sysplex environment

2011-02-28 Thread Staller, Allan
Yup! I read the OP too fast! Al Staller | Z Systems Programmer | KBM Group | (Tel) 972 664 3565 | allan.stal...@kbmg.com -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Stan Weyman Sent: Friday, February 25, 2011 4:29 PM To:

Re: ZCIOWAIT message

2011-02-28 Thread Thomas Dunlap
Eric, ZCIOWAIT indicates VTAM terminal control wait. My first guess is that you are function shipping to another CICS region using VTAM connections between the regions and you are looking at the front-end transaction. In this case this is a normal situation. As for optimizing, it is

Re: Yahoo

2011-02-28 Thread Shmuel Metz (Seymour J.)
In 250107.47615...@web161408.mail.bf1.yahoo.com, on 02/27/2011 at 11:29 PM, Ed Gould ps2...@yahoo.com said: I do not know how often you visit the yahoo site for the group. This is not a group; it is a mailing list. Messages from this group are gated to a news group called

Re: ALPHACON Macro for EZYTRIEVE

2011-02-28 Thread Paul Peplinski
On Sun, 27 Feb 2011 18:22:54 -0600, Anthony Fletcher flet...@nz1.ibm.com wrote: Has anyone on the list heard of a macro called ALPHACON? It is apparently something that can be used either with EZYTRIEVE itself or with the IBM replacement for EZYTRIEVE. It is to convert a character representation

Re: Yahoo

2011-02-28 Thread Ken Porowski
Don't know if this was the beginning of it or not Newsgroups: bit.listserv.ibm-main From: broi...@ibm-main.gti.net (Jeffrey R. Broido) Date: 7 Mar 2004 05:14:41 -0800 Local: Sun, Mar 7 2004 8:14 am Subject: Re: [forbidden word for peons]: Off topic posts Print | Individual message | Show

Re: Removing BINS from RMM

2011-02-28 Thread David G. Schlecht
Thanks for the response and the suggestion. Yes, RMM knows of the changes. Are there any other ideas out there? This really must be a pretty common exercise. I can't imagine no one else has done this. Is there something more I need to change in RMM so I can remove the bins? David G. Schlecht

Re: Removing BINS from RMM

2011-02-28 Thread Pinnacle
- Original Message - From: David G. Schlecht dschle...@doit.nv.gov Newsgroups: bit.listserv.ibm-main Sent: Monday, February 28, 2011 10:37 AM Subject: Re: Removing BINS from RMM Thanks for the response and the suggestion. Yes, RMM knows of the changes. Are there any other ideas out

TRX Replacement

2011-02-28 Thread Dennis Schaffer
Hi, We're running TRX from OES Inc., and we're looking for alternatives. TRX provides allocation and i/o services for the TSO/ISPF environment. TRX allows us to avoid maintaining logon procs with hard-coded dataset names or clists/execs to dynamically allocate TSO/ISPF datasets, by providing

Re: TRX Replacement

2011-02-28 Thread Pommier, Rex R.
Dyna-step from Tone Software? www.tonesoft.com. I haven't used the product, but in a former life I worked with some of their other software and had no problems with them. Rex -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Dennis

Re: TRX Replacement

2011-02-28 Thread Stocker, Herman
Have you looked into: Thomas Conley of Pinnacle Consulting Group, Inc Dynamic ISPF Starter Set (DISS) Regards, Herman Stocker It is impossible to make anything foolproof, because fools are so ingenious. -- Robert Heinlein -Original Message- From: IBM Mainframe Discussion List

Re: TRX Replacement

2011-02-28 Thread Pinnacle
- Original Message - From: Dennis Schaffer dennis.schaf...@gmail.com Newsgroups: bit.listserv.ibm-main Sent: Monday, February 28, 2011 12:57 PM Subject: TRX Replacement Hi, We're running TRX from OES Inc., and we're looking for alternatives. TRX provides allocation and i/o services

BPXWDYN

2011-02-28 Thread Scott Ford
I am trying to to the following in A LE Cobol 4.1 program, a Hi all: I am trying to to the following in A LE Cobol 4.1 program, a STC . I have specified a Select for the file  SELECT FILEOUT   ASSIGN   TO FILEOUT   ORGANIZATION IS SEQUENTIAL  

Re: BPXWDYN

2011-02-28 Thread Pinnacle
- Original Message - From: Scott Ford scott_j_f...@yahoo.com Newsgroups: bit.listserv.ibm-main Sent: Monday, February 28, 2011 3:59 PM Subject: BPXWDYN I am trying to to the following in A LE Cobol 4.1 program, a Hi all: 01 DYNSYSOUT-TEMP. 10 FILLER PIC X(18) VALUE ' ALLOC

Re: BPXWDYN

2011-02-28 Thread Barkow, Eileen
Try adding unalloc keyword: 'FREE FILE DD(FILEOUT) UNALLOC' -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Scott Ford Sent: Monday, February 28, 2011 3:57 PM To: IBM-MAIN@bama.ua.edu Subject: BPXWDYN I am trying to to the following in

Connection locked

2011-02-28 Thread HELIO
All list, I have the following situation: A conection was locked and could not drop it, we have to stop the tcpip profile. A connection is terminal the CICS, D TCPIP,TN3270U,TELNET,CONN,PORT=23,IPA=172.18.35.2 EZZ6064I TELNET CONNECTION DISPLAY 812 EN

Re: Connection locked

2011-02-28 Thread Rabbe, Luke
What happens if you try V TCPIP,tcpip_procname,DROP,CONN=000EECA5? Luke -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of HELIO Sent: Monday, February 28, 2011 3:09 PM To: IBM-MAIN@bama.ua.edu Subject: Connection locked All list, I have

Re: BPXWDYN

2011-02-28 Thread Scott Ford
Tried the ALLOC DD(FILEOUT) SYSOUT(X) MSG(WTP ,   still same Tom: Tried the ALLOC DD(FILEOUT) SYSOUT(X) MSG(WTP ,   still same issue. Eileen: I tried the 'FREE FILE DD(FILEOUT) UNALLOC' same issue. I wonder if I hit a bug ...   Scott J Ford   From: Barkow,

Re: s0c4 in INIT TCBCMP field not related to any known problem

2011-02-28 Thread Joe D'Alessandro
Hello: BMC identified PTF BPG6106 as the fix for this issue. regards, Joe D'Alessandro -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO

Re: BPXWDYN

2011-02-28 Thread McKown, John
You might want to try adding the parameter SPIN(UNALLOC) to the ALLOC parameters. Just a guess. -- John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets® 9151 Boulevard 26 . N. Richland Hills . TX 76010 (817) 255-3225 phone . john.mck...@healthmarkets.com .

Re: BPXWDYN

2011-02-28 Thread Sam Siegel
snip I am trying to to the following in A LE Cobol 4.1 program, a STC . I have specified a Select for the file SELECT FILEOUT ASSIGN TO FILEOUT ORGANIZATION IS SEQUENTIAL FILE STATUS IS FILEOUT-STATUS. I build the

Source of the JCLim column on the SDSF 'JC' Panel

2011-02-28 Thread Mark Yuhas
I cannot find any reference as to the source of the JCLim column on the SDSF 'JC' Panel. I have tried several searches, but, to no avail. The only reference is the SDSF manual defining the column. I could not find any reference to the source of the data. The ISF.SISFSRC data set provided no

Re: TRX Replacement

2011-02-28 Thread Ted MacNEIL
You can also cache the directories for the ISPF libraries in LLA (although IBM is now saying it's only for LINKLIST loadlibs). When did that change back, and where is it documented? I remember when IBM changed LLA from LinkList Look Aside to Library Look Aside. I did NOT get that memo! - Ted

Re: Source of the JCLim column on the SDSF 'JC' Panel

2011-02-28 Thread Mark Zelden
On Mon, 28 Feb 2011 14:30:18 -0800, Mark Yuhas mark.yu...@paccar.com wrote: I cannot find any reference as to the source of the JCLim column on the SDSF 'JC' Panel. I have tried several searches, but, to no avail. The only reference is the SDSF manual defining the column. I could not find any

Re: Source of the JCLim column on the SDSF 'JC' Panel

2011-02-28 Thread Mark Zelden
On Mon, 28 Feb 2011 17:21:21 -0600, Mark Zelden mzel...@flash.net wrote: On Mon, 28 Feb 2011 14:30:18 -0800, Mark Yuhas mark.yu...@paccar.com wrote: I cannot find any reference as to the source of the JCLim column on the SDSF 'JC' Panel. I have tried several searches, but, to no avail. The only

Re: BPXWDYN

2011-02-28 Thread Scott Ford
I added it missing ')' the allocate is working fine, the free comes back with a 0 return code and the 'DD' is still allocated I am missing something, muse be my old age memory   Scott J Ford   From: Sam Siegel s...@pscsi.net To: IBM-MAIN@bama.ua.edu Sent:

Re: BPXWDYN

2011-02-28 Thread Sam Siegel
Look at the output descriptor. http://publib.boulder.ibm.com/infocenter/zos/v1r9/index.jsp?topic=/com.ibm.zos.r9.bpxb600/wdyn.htm http://publib.boulder.ibm.com/infocenter/zos/v1r9/index.jsp?topic=/com.ibm.zos.r9.bpxb600/wdyn.htmLooks like this might be needed for freeing a DD SYSOUT= allocation.

Re: Connection locked

2011-02-28 Thread Chris Mason
Hélio In case you didn't see precisely what Luke was asking you to do - and I'll admit it was only when I noticed that the TELNET flavour of the VARY command did *not* include the CONN option - he is saying that it was incorrect of you to be using the TN3270E program address space name but

Re: BPXWDYN

2011-02-28 Thread Scott Ford
Yeah Sam, I see said the 'blind man' let me give it a try, ty , I appreciate it   Scott J Ford   From: Sam Siegel s...@pscsi.net To: IBM-MAIN@bama.ua.edu Sent: Mon, February 28, 2011 7:03:04 PM Subject: Re: BPXWDYN Look at the output descriptor.

Re: BPXWDYN

2011-02-28 Thread Scott Ford
A I found ti guys/gals, thanks for the help the allocate was correct : ALLOC DD(xx) SYSOUT(X) MSG(WTP) and Eileen was right , I misunderstood, FREE DD(xx) SYSOUT(Y) SPIN(UNALLOC) what i missed was the spin out class ..once I chanegd the class it is working like a champ.. Once