Hello:
Yesterday we've executed a ipl in our production lpar. It didn't work. Today
we open a PMR in IBM support.
Regards
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu
Hello group,
is it possible to determine with SMF-Records (14,41,42,..) if a
dataset-block was read from disk, lla (direcotory read), vlf (modules), or
PDS/E-caching. We want to optimize our I/O processing.
Any hint appreciated. With best regards
Monika
Hi,
Just a gentle reminder that we have the next meeting of the GSE Large Systems
Working Group on the 19th July 2011 at CA Ditton Park.
Agenda and registration details can be found at:
http://lsx.gse.org.uk/future.html
Regards,
_
Mark Wilson
Technical
Hi,
please excuse me for any lack of knowledge in this area,
I have a compenet running under USS which used the JDBC jars from DB2 8.10V
.
I needed to upgrade it to run under J6.0
*/Z110/usr/lpp/java/J6.0/bin: ./java -version *
*java version 1.6.0
*
*Java(TM) SE
You can start OAM with the command: S OAM
http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/dgt2o361/5.3
HOWEVER - OAM must be defined as a subsystem in the IEFSSNnn member of
PARMLIB before you can do it. So, most likely, you need up update
IEFSSNnn (and possibly create an IGDSMSnn
Well, as of today, Sizer is broken again. I get the MQ errors again. For the
health checker structure (which previously gave me a cflevel13 answer) I now
get the MQ error, too.
A hitmiss tool.
Barbara
--
For IBM-MAIN
Hi,
We’ve started using WLM managed initiators.
Using JES2 commands we can specify the maximum number of initiators per class,
and even per system.
The number of jobs per system is visible and changeable using the JC command.
Does anyone know of a utility that can display and change the values
Sorry, I think I messed up my last entry.
Any way, you should be able to convert your code to SYSREXX (System REXX).
Also, I hate to bring it up because of the controversy about marketing, but we
have automation products (SyzCMD/z and SyzMPF/z) which provide the type of
automation you are
this stuff below is from the stratosphere region of excellence -- ἀρετή , as
the ancient greeks would say. kudos to you, Mr Golob.
/s/ tuco bonno;
Graduate, College of Conflict Management;
University of SouthEast Asia;
I partied on the Ho Chi Minh Trail - tiến lên !!
-Original
On Fri, 8 Jul 2011 14:32:46 -0500, Chase, John jch...@ussco.com wrote:
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Starr, Alan
2) You have some code following the EXEC CICS ENQ to detect ENQBUSY
Actually, that's not necessary unless you want to enable the task
??? ?? ??? gad...@malam.com wrote in message
news:c11ded818b17214792b97fba28712bed04fa69c...@jer-email1.jer.ad.malam
.com...
Hi,
We've started using WLM managed initiators.
Using JES2 commands we can specify the maximum number of initiators
per class, and even per system.
The number of
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Matan Cohen
Hi,
please excuse me for any lack of knowledge in this area,
I have a compenet running under USS which used the JDBC jars from DB2 8.10V
.
I needed to upgrade it to run under J6.0
Thanks, but I'm looking for something that doesn't require command.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of
Vernooij, CP - SPLXM
Sent: Monday, July 11, 2011 2:43 PM
To: IBM-MAIN@bama.ua.edu
Subject: Re: Managing WLM manged
Using JES2 commands we can specify the maximum number of initiators per
class, and even per system.
The number of jobs per system is visible and changeable using the JC
command.
Does anyone know of a utility that can display and change the values per
system?
Thanks, but I'm looking for
I am looking for something I can show the operators.
CA-SYSVIEW doesn't have it.
Gadi
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of
Lizette Koehler
Sent: Monday, July 11, 2011 3:09 PM
To: IBM-MAIN@bama.ua.edu
Subject: Re: Managing WLM
I am looking for something I can show the operators.
CA-SYSVIEW doesn't have it.
Gadi
Using JES2 commands we can specify the maximum number of initiators
per
class, and even per system.
The number of jobs per system is visible and changeable using the JC
command.
Does anyone know
IIRC, this would be a bad thing for CICS.
CICS does not like OS waits which would be caused by ENQ/DEQ (CICS waits
are another thing).
I am not a CICS person, but I would think that there are EXEC CICS
equivalents to ENQ/DEQ that would be
better for this purpose.
snip
Now we are trying the
Please ignore the ratbag and keep posting here.
OK - can we stop with the name calling personal attacks get back to
business?
It's been awhile since I read the original post that started this whole
chain,
but IIRC, that person gave us an opinion -which you may or may not agree
with.
I
I think we will. Thank you all for commenting.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of
R.S.
Sent: Sunday, July 10, 2011 11:29 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: DS8XXX Syslog Mirroring Question
W dniu 2011-07-08 23:22,
For program load I think you want SMF 42 Subtype 6(?). Possibly with the
use of an LLA exit.
AFAIK, there is no native method to determine this information.
Several of the 3rd-party products that existed before LLA provide
statistical and loadlib information for a specific module out of the
box.
TRT is just one of a handful of instructions that modify all (or in the
case of TRT) some of R2.
===
Wayne Driscoll
OMEGAMON DB2 L3 Support/Development
wdrisco(AT)us.ibm.com
===
From:
Mike Schwab
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Staller, Allan
IIRC, this would be a bad thing for CICS.
CICS does not like OS waits which would be caused by ENQ/DEQ (CICS
waits
are another thing).
I am not a CICS person, but I would think that there are
Bravo, Sam.
Great post and thank you for contributing and maintaining the CBTTAPE all these
years.
Greg Dorner
CONFIDENTIALITY NOTICE: This e-mail, including any attachments, may contain
confidential, privileged and/or proprietary information which is solely for the
use of the intended
On Sat, 9 Jul 2011 11:50:19 -0700, Edward Jaffe wrote:
While I'll readily admit there might others, this is the first and only
one I've heard of that does this.
I looked. I find 30 macros in SYS1.MACLIB that issue USING. 5 of them
use PUSH/POP. A few of them leave the USING in effect when
On Sun, 10 Jul 2011 23:46:07 -0500, Greg Dini dini_g...@emc.com wrote:
Is an IPL required to bring OAM up for the first time?
No, but you do need to at least dynamically define the subsystem (SETSSI ADD)
if you did not already define it for the current IPL. You should also have your
library
On Mon, 11 Jul 2011 12:44:09 +0300, #1490;#1491;#1497; #1489;#1503;
#1488;#1489;#1497; gad...@malam.com wrote:
Hi,
Weve started using WLM managed initiators.
Using JES2 commands we can specify the maximum number of initiators per class,
and even per system.
The number of jobs per system is
Two weeks left before the VM Workshop at OSU. The grid is now pretty much
complete. You can view it at _www.vmworkshop.org_
(http://www.vmworkshop.org) ..
General Sessions include:
John Franciscovich (IBM) will open the workshop with an update on the VM
Platform.
Bill Carico will be
thanks ,
I ordered the required service although I don't believe it will fix it .
On Mon, Jul 11, 2011 at 3:02 PM, Chase, John jch...@ussco.com wrote:
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Matan Cohen
Hi,
please excuse me for any lack of knowledge
On Mon, 11 Jul 2011 08:53:31 -0500, Tom Marchant wrote:
I looked. I find 30 macros in SYS1.MACLIB that issue USING. 5 of them
use PUSH/POP. A few of them leave the USING in effect when they end.
The problem that occurs because of the lack of PUSH/POP is an assembly
error. IMO this is far
* OK'd by Darren
With HTML 5 getting near to becoming a standard, I
have updated my courses that relate to developing
Web applications on z/OS. These courses do not require
using any server other than the free HTTP servers that
come with z/OS; they do not require CICS.
Classic z/OS
Sergio
We have here a lot of EXEC's that is used from VM OPERATOR to display,
activate, deactivate lines from VTAM.
Ed Gould has opened up the possibility that you might consider changing your
operational environment and changing the REXX Clists you use in order to
achieve what you really
At 7/10/2011 03:47 PM, Justin R. Bendich wrote:
I agree with Scott and Walter that it must be above the bar if it's
not addressable in AMODE 31. Understand that that's below GAGALAND,
but, yeah, i guess you need another name.
What?? That didn't catch on either
Hello Alan, and all others.
Thanks very much for your help.
Run fine, very good.
But, for give VTAM commands under ZOS, need insert ADDRESS VTAM ?
Look below please:
Under Z/VM :
3 *-* set secuser vtam *
set secuser vtam *
4 *-* cp sleep 2 sec
cp sleep 2 sec
Sérgio,
You have to use AXRCMD API to issue z/OS commands, and AXRWTO to WTO.
Here are some samples used in our sysprog Lpar:
/**/
/* Verifica os Subsistemas Ativos */
/**/
Sysid = MVSVAR('SYSNAME')
In 3636987791660692.wa.paulgboulderaim@bama.ua.edu, on
07/11/2011
at 09:40 AM, Paul Gilmartin paulgboul...@aim.com said:
Again, it depends on what programmers are accustomed to. If,
magically overnight, the relevant DROP were added to every macro in
SYS1.MACLIB that alters a register,
In 0B22DBD9E9454E45BEDB27BC0798FD92@graham, on 07/10/2011
at 05:13 PM, Graham Hobbs gho...@cdpwise.net said:
Thereafter zero plans to use this list again - given the posting's
brevity I didn't even plan to ask Darren!
I would consider it abusive to post to a mailing list with the intent
of
In 4e1a90cc.1040...@cbttape.org, on 07/11/2011
at 01:57 AM, Sam Golob sbgo...@cbttape.org said:
We must not forget what this wonderful forum is for. It is for
bringing up problems in the MVS (z/OS) area,
And the other IBM mainframe platforms as well.
P.S. Shai, you don't have to
In 49o317tmgaeo59mfmbt0qgppgivustu...@4ax.com, on 07/04/2011
at 06:52 PM, Binyamin Dissen bdis...@dissensoftware.com said:
It is possible via a SAF exit.
No.
Every module LOAD goes thru there
Only if by LOAD you mean the LOAD macro or at least the standard Fetch
routine. It is not true for
In p06240800ca3eb2ceae91@[192.168.1.11], on 07/09/2011
at 10:04 PM, Robert A. Rosenberg hal9...@panix.com said:
If the macro takes it upon itself to issue a USING on one of the 4
linkage registers [instead of just using the usual
Value-DSECT(Register) displacement addressing] it should clean
On Mon, 11 Jul 2011 14:46:48 -0400 Shmuel Metz (Seymour J.)
shmuel+ibm-m...@patriot.net wrote:
:In 49o317tmgaeo59mfmbt0qgppgivustu...@4ax.com, on 07/04/2011
: at 06:52 PM, Binyamin Dissen bdis...@dissensoftware.com said:
:It is possible via a SAF exit.
:No.
Yes it is. And I have done it.
On Mon, 4 Jul 2011 18:52:15 +0300, Binyamin Dissen bdis...@dissensoftware.com
wrote:
On Mon, 4 Jul 2011 11:40:05 -0400 Gerhard Postpischil gerh...@valley.net
wrote:
:On 7/4/2011 7:42 AM, Hilary Hurwitz wrote:
: I really miss one function - provided by FAQS/ASO.
: At the end of every batch job,
Why not continue using the java you have been using that worked?
Rob Schramm
Senior Systems Consultant
Imperium Group
On Mon, Jul 11, 2011 at 10:39 AM, Matan Cohen matancohen...@gmail.com wrote:
thanks ,
I ordered the required service although I don't believe it will fix it .
On Mon, Jul
On Sat, 9 Jul 2011 21:03:09 -0400, Shmuel Metz (Seymour J.)
shmuel+ibm-m...@patriot.net wrote:
In
of2db99b4a.0442f6f1-on882578c7.0057dc8d-882578c7.0058d...@sce.com,
on 07/08/2011
at 09:10 AM, Skip Robinson jo.skip.robin...@sce.com said:
But we're talking about customer generated usermods
On Sun, 10 Jul 2011 23:48:57 -0500, Barbara Nitz wrote:
The graphic things are a quotation mark, but it seems hard to figure that
out initially.
+1
It was more intuitive than anything IBM throws at their customers (see SR)
:-). I know you're not responsible for SR, Walt!
Maybe it's getting
hi all,
on an IBM educational ppt presentation we googled, including sound, he
talked about mapping macros for websphere smf record 120.
does anybody know about these assembler mapping macros, and where to find them?
best
stephen
---
Dr. Stephen Fedtke
Enterprise-IT-Security.com
Seestrasse
Maybe it's getting better. It now uses HTTP instead of insisting on HTTPS.
Really? After authentification (which *I* would insist on being https) it stays
https for me. Which makes a lot of sense, as we don't want our company's
software problems to become common knowledge.
o I had the site
HI,
I send message to the old and the new users list to indicate that
YOU ARE IN MY LIST.
I receive many requests. Most of the people are in the list.
If somebody did not receive my note, please send me email and I will add you.
One point to mention. I used the word without *** nothing was
hi all,
several sources provide used cpu time. calculating the difference between
two points of time allows to calculate the required cpu time for particular
parts of the processing.
question: which is the most efficient and reliable method to determine the
cpu time used in order to apply the
48 matches